17436-17438 W INDEX ST 91344
Certificate Information: 17436-17438 W INDEX ST 91344
- Application / Permit
- 24014-20000-01924
- Plan Check / Job No.
- B24VN06370
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- eEPLAN CONVERT 710 SF IRREGULAR SHAPED PORTION OF (E) SFD TO CREATE (N) DUPLEX per SB9 Two-Unit Development Ca Govt Code 65852.21 AND ADD 9'-3" X 15'-7.5". ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 10/1/2024
- Issuing Office
- Current Status
- CofO Issued on 9/22/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/8/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 5/23/2024 | RAPHAEL ROSAS |
| Corrections Issued | 5/28/2024 | RAPHAEL ROSAS |
| Quality Review Completed | 5/29/2024 | STEVEN KIM |
| Applicant returned to address corrections | 6/18/2024 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 9/16/2024 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 9/26/2024 | RAPHAEL ROSAS |
| Plan Check Approved | 9/30/2024 | RAPHAEL ROSAS |
| Issued | 10/1/2024 | APPLICANT |
| CofO in Progress | 9/9/2025 | STEVEN BACK |
| Permit Finaled | 9/22/2025 | JOHN JANSON |
| CofO Issued | 9/22/2025 | JOHN JANSON |
| Permit Finaled | 9/22/2025 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 6/5/2024 | CARLOS RAMIREZ |
| Roof/Waste drainage to street | Cleared | 6/5/2024 | CARLOS RAMIREZ |
| Grading Pre-Inspection | Cleared | 6/6/2024 | CHARLES POWELL |
| Eng Process Fee Ord 176,300 | Cleared | 6/7/2024 | CARLOS RAMIREZ |
| Sewer availability | Cleared | 6/7/2024 | CARLOS RAMIREZ |
| GPI Written Notices | Cleared | 6/18/2024 | RAPHAEL ROSAS |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Shahbaz,, Shant Pierre; Lic. No.: C93079 | 15445 VENTURA BLVD #63 SHERMAN OAKS, CA 91403 |
| Engineer | Shahbaz,, Shant Pierre; Lic. No.: NA93079 | , |
Inspector Information
| JEFFREY PARD, (818) 774-4312 | Office Hours: 7:00-8:00 AM MON-FRI |
| STEVEN BACK, (818) 774-4312 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 11/25/2024 | Conditional Approval | HENRY KIM |
| Footing/Foundation/Slab | 12/2/2024 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 1/2/2025 | Partial Approval | STEVEN BACK |
| Green Building Rough | 1/2/2025 | Not Ready for Inspection | STEVEN BACK |
| MERV13>=Rough | 1/2/2025 | Not Ready for Inspection | STEVEN BACK |
| PLUMBING-Rough | 1/10/2025 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 1/17/2025 | Partial Approval | STEVEN BACK |
| MERV13>=Rough | 1/17/2025 | Not Ready for Inspection | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 1/24/2025 | Corrections Issued | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 2/6/2025 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 2/6/2025 | Partial Approval | STEVEN BACK |
| BUILDING-Rough-Frame | 2/25/2025 | Approved | STEVEN BACK |
| ELECTRICAL-Rough | 2/25/2025 | Approved | STEVEN BACK |
| Green Building Rough | 2/25/2025 | Approved | STEVEN BACK |
| HVAC-Rough | 2/25/2025 | Corrections Issued | STEVEN BACK |
| MERV13>=Rough | 2/25/2025 | Approved | STEVEN BACK |
| Drywall Nailing | 3/11/2025 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 3/11/2025 | Approved | STEVEN BACK |
| Masonry Wall/Backfill | 4/25/2025 | Not Ready for Inspection | STEVEN BACK |
| Sewer | 4/25/2025 | Approved | STEVEN BACK |
| ELECTRICAL-Final | 6/13/2025 | Not Ready for Inspection | STEVEN BACK |
| HVAC-Final | 6/13/2025 | Not Ready for Inspection | STEVEN BACK |
| PLUMBING-Final | 6/13/2025 | Not Ready for Inspection | STEVEN BACK |
| Final | 7/16/2025 | Corrections Issued | STEVEN BACK |
| Green Building Final | 7/16/2025 | Not Ready for Inspection | STEVEN BACK |
| MERV13>=Final | 7/16/2025 | Approved | STEVEN BACK |
| Smoke Detectors | 7/16/2025 | Approved | STEVEN BACK |
| Final | 8/4/2025 | Corrections Issued | STEVEN BACK |
| Green Building Final | 8/4/2025 | Approved | STEVEN BACK |
| Final | 9/5/2025 | No Access for Inspection | JEFFREY HARTLINE |
| Enclosure/Fence | 9/9/2025 | Approved | STEVEN BACK |
| Final | 9/9/2025 | OK to Issue CofO | STEVEN BACK |
| Service/Power Release | 9/9/2025 | Approved | STEVEN BACK |
| Special/Order Compliance | 9/9/2025 | Approved | STEVEN BACK |