10235-10237 N MT GLEASON AVE 91040
Certificate Information: 10235-10237 N MT GLEASON AVE 91040
- Application / Permit
- 24014-20000-01046
- Plan Check / Job No.
- B24VN03490
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- EPLAN REMOVE (E) 941 SF EXCEPT FOR 57'-10" OF WALL AND FOUNDAITON AT NORTHERN PORTION. REBUILD EXISTING AND PROPOSED 14'-3" X 44'-3" IRREGULAR SHAPED ADDITION AND MAJOR REMODEL TO (E) SFD. ADD 23'-3" X 43'-11" IRREGULAR SHAPED AT REAR OF SFD FOR ATTACHED ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (e). NFPA 13D FIRE SPRINKLERS THROUGHOUT.
- Permit Issued
- Issued on 9/17/2024
- Issuing Office
- Current Status
- CofO Issued on 4/10/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/18/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 3/28/2024 | RAPHAEL ROSAS |
| Corrections Issued | 4/5/2024 | RAPHAEL ROSAS |
| Quality Review Completed | 4/9/2024 | STEVEN KIM |
| Applicant returned to address corrections | 5/23/2024 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 5/31/2024 | RAPHAEL ROSAS |
| Plan Check Approved | 8/21/2024 | RAPHAEL ROSAS |
| Issued | 9/17/2024 | APPLICANT |
| CofO in Progress | 2/18/2026 | DAVID ANDERSON |
| Permit Finaled | 4/10/2026 | RUBEN SALAS |
| CofO Issued | 4/10/2026 | RUBEN SALAS |
| Permit Finaled | 4/10/2026 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 4/12/2024 | BIAINA HARITUNIAN |
| Eng Process Fee Ord 176,300 | Cleared | 4/17/2024 | BIAINA HARITUNIAN |
| Sewer availability | Cleared | 4/17/2024 | BIAINA HARITUNIAN |
| Low Impact Development (LID) | Cleared | 4/23/2024 | SAMUEL LINN |
| Grading Pre-Inspection | Cleared | 5/2/2024 | CHARLES POWELL |
| Roof/Waste drainage to street | Cleared | 5/8/2024 | BIAINA HARITUNIAN |
| GPI Written Notices | Cleared | 5/31/2024 | RAPHAEL ROSAS |
Contact Information
| Contractor | Savs Enterprises; Lic. No.: 814956-B | , |
| Engineer | Keshishian,, Anthony; Lic. No.: C89551 | 2654 RISA D GLENDALE, CA 91208 |
Inspector Information
| MATTHEW NELSON, (818) 374-1168 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 1/21/2025 | Conditional Approval | MATTHEW NELSON |
| Excavation/Setback/Form/Re-Bar | 1/21/2025 | Not Ready for Inspection | MATTHEW NELSON |
| Excavation/Setback/Form/Re-Bar | 1/22/2025 | Corrections Issued | DAVID ANDERSON |
| Footing/Foundation/Slab | 1/22/2025 | Not Ready for Inspection | DAVID ANDERSON |
| Floor/Roof Diaphrgm/Shear Wall | 2/27/2025 | Partial Approval | DAVID ANDERSON |
| Footing/Foundation/Slab | 2/27/2025 | Approved | DAVID ANDERSON |
| PLUMBING-Rough | 2/27/2025 | Partial Approval | DAVID ANDERSON |
| Floor/Roof Diaphrgm/Shear Wall | 3/26/2025 | Partial Approval | DAVID ANDERSON |
| Insulation | 3/26/2025 | Partial Approval | DAVID ANDERSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/15/2025 | Partial Approval | DAVID ANDERSON |
| BUILDING-Rough-Frame | 5/16/2025 | Not Ready for Inspection | DAVID ANDERSON |
| ELECTRICAL-Rough | 5/16/2025 | Corrections Issued | DAVID ANDERSON |
| Green Building Rough | 5/16/2025 | Not Ready for Inspection | DAVID ANDERSON |
| HVAC-Rough | 5/16/2025 | Approved | DAVID ANDERSON |
| PLUMBING-Rough | 5/16/2025 | Approved | DAVID ANDERSON |
| Verify Sprinkler Sign Off | 5/16/2025 | Approved | DAVID ANDERSON |
| Deputy Wood Construction | 5/22/2025 | Conditional Approval | DAVID MATSON |
| BUILDING-Rough-Frame | 5/29/2025 | Approved | DAVID ANDERSON |
| ELECTRICAL-Rough | 5/29/2025 | Approved | DAVID ANDERSON |
| Floor/Roof Diaphrgm/Shear Wall | 5/29/2025 | Approved | DAVID ANDERSON |
| Green Building Rough | 5/29/2025 | Approved | DAVID ANDERSON |
| Shower Pan | 5/29/2025 | Approved | DAVID ANDERSON |
| Insulation | 6/6/2025 | Approved | DAVID ANDERSON |
| Interior/Exterior Lathing | 6/6/2025 | Partial Approval | DAVID ANDERSON |
| Drywall Nailing | 6/12/2025 | Approved | DAVID ANDERSON |
| Interior/Exterior Lathing | 6/18/2025 | Partial Approval | DAVID ANDERSON |
| Interior/Exterior Lathing | 7/10/2025 | Approved | DAVID ANDERSON |
| Pre-Inspection | 9/3/2025 | Approved | DAVID ANDERSON |
| ELECTRICAL-Final | 10/14/2025 | Corrections Issued | DAVID ANDERSON |
| Green Building Final | 10/14/2025 | Not Ready for Inspection | DAVID ANDERSON |
| SGSOV-Seismic Gas S/O Valve | 10/14/2025 | SGSOV Not Ready | DAVID ANDERSON |
| Smoke Detectors | 10/14/2025 | Approved | DAVID ANDERSON |
| ELECTRICAL-Final | 10/21/2025 | Approved | DAVID ANDERSON |
| Service/Power Release | 11/6/2025 | Approved | DAVID MATSON |
| Final | 2/17/2026 | OK to Issue CofO | DAVID ANDERSON |
| Green Building Final | 2/17/2026 | Approved | DAVID ANDERSON |
| SGSOV-Seismic Gas S/O Valve | 2/17/2026 | SGSOV Approved | DAVID ANDERSON |