19217 W OLYMPIA ST 91326
Certificate Information: 19217 W OLYMPIA ST 91326
- Application / Permit
- 24014-20000-00535
- Plan Check / Job No.
- B24VN01668
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- ePlan. PROPOSED 2-STORY ACCESSORY DWELLING UNIT PER ORDINANCE.
- Permit Issued
- Issued on 9/25/2024
- Issuing Office
- Current Status
- CofO Issued on 4/4/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 2/12/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 2/22/2024 | MICHAEL LOPEZ |
| Corrections Issued | 3/7/2024 | MICHAEL LOPEZ |
| Quality Review Completed | 3/7/2024 | GARO TELMI |
| Applicant returned to address corrections | 6/4/2024 | MICHAEL LOPEZ |
| Applicant returned to address corrections | 6/24/2024 | MICHAEL LOPEZ |
| Applicant returned to address corrections | 7/19/2024 | MICHAEL LOPEZ |
| Plan Check Approved | 9/18/2024 | MICHAEL LOPEZ |
| Issued | 9/25/2024 | APPLICANT |
| CofO in Progress | 12/15/2025 | DAVID SCANTLIN |
| Permit Finaled | 4/4/2026 | MICHAEL PELHAM |
| CofO Issued | 4/4/2026 | MICHAEL PELHAM |
| Permit Finaled | 4/4/2026 | MICHAEL PELHAM |
Permit Application Clearance Information
| Address approval | Cleared | 3/19/2024 | BIAINA HARITUNIAN |
| Miscellaneous | Cleared | 3/19/2024 | BRENNEN OBETO |
| Roof/Waste drainage to street | Cleared | 3/19/2024 | BIAINA HARITUNIAN |
| Eng Process Fee Ord 176,300 | Cleared | 3/20/2024 | BIAINA HARITUNIAN |
| Sewer availability | Cleared | 3/20/2024 | BIAINA HARITUNIAN |
| Grading Pre-Inspection | Cleared | 3/21/2024 | CHARLES POWELL |
| GPI Written Notices | Cleared | 6/24/2024 | GERMAN RODRIGUEZ MENDOZA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 3625 BEVERLY RIDGE DRIVE SHERMAN OAKS, CA 91423 |
Inspector Information
| JACK KARGODORIAN, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
| KRISTEN CAUSEY, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 1/28/2025 | Corrections Issued | DAVID SCANTLIN |
| Pre-Inspection | 1/28/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Excavation/Setback/Form/Re-Bar | 2/4/2025 | Approved | DAVID SCANTLIN |
| Pre-Inspection | 2/4/2025 | Approved | DAVID SCANTLIN |
| PLUMBING-Rough | 3/5/2025 | Partial Approval | DAVID SCANTLIN |
| Wood Frame | 3/5/2025 | Partial Approval | DAVID SCANTLIN |
| Insulation | 3/18/2025 | Partial Approval | KRISTEN CAUSEY |
| Drywall Nailing | 3/24/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Wood Frame | 3/24/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Wood Frame | 4/8/2025 | Partial Approval | DAVID SCANTLIN |
| ELECTRICAL-Rough | 5/7/2025 | Approved | DAVID SCANTLIN |
| HVAC-Rough | 5/7/2025 | Approved | DAVID SCANTLIN |
| PLUMBING-Rough | 5/7/2025 | Approved | DAVID SCANTLIN |
| Wood Frame | 5/7/2025 | Partial Approval | DAVID SCANTLIN |
| Floor/Roof Diaphrgm/Shear Wall | 5/14/2025 | Partial Approval | KRISTEN CAUSEY |
| BUILDING-Rough-Frame | 5/27/2025 | Approved | DAVID SCANTLIN |
| Green Building Rough | 5/27/2025 | Approved | DAVID SCANTLIN |
| Insulation | 5/27/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Interior/Exterior Lathing | 5/27/2025 | Partial Approval | DAVID SCANTLIN |
| Verify Sprinkler Sign Off | 5/27/2025 | Approved | DAVID SCANTLIN |
| Drywall Nailing | 6/6/2025 | Approved | KRISTEN CAUSEY |
| Shower Pan | 6/16/2025 | Approved | SCOTT SOBEL |
| Interior/Exterior Lathing | 6/20/2025 | Partial Approval | ARUTYUN MADATYAN |
| BUILDING-Rough-Frame | 9/24/2025 | Corrections Issued | DAVID SCANTLIN |
| ELECTRICAL-Rough | 9/24/2025 | Partial Approval | DAVID SCANTLIN |
| ELECTRICAL-Rough | 10/8/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| ELECTRICAL-Final | 10/23/2025 | Partial Inspection | KRISTEN CAUSEY |
| Special/Order Compliance | 11/4/2025 | Approved | DAVID SCANTLIN |
| BUILDING-Rough-Frame | 11/24/2025 | Approved | DAVID SCANTLIN |
| Final | 11/24/2025 | Corrections Issued | DAVID SCANTLIN |
| Footing/Foundation/Slab | 11/24/2025 | Approved | DAVID SCANTLIN |
| Green Building Final | 11/24/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 11/24/2025 | SGSOV Approved | DAVID SCANTLIN |
| Service/Power Release | 11/24/2025 | Not Ready for Inspection | DAVID SCANTLIN |
| Smoke Detectors | 11/24/2025 | Approved | DAVID SCANTLIN |
| Final | 12/12/2025 | OK to Issue CofO | DAVID SCANTLIN |
| Green Building Final | 12/12/2025 | Approved | DAVID SCANTLIN |
| Service/Power Release | 12/12/2025 | Approved | DAVID SCANTLIN |
| Special/Order Compliance | 2/6/2026 | Corrections Issued | DAVID SCANTLIN |
| Special/Order Compliance | 4/1/2026 | Approved | DAVID SCANTLIN |