6051 E ROY ST 90042

Certificate Information: 6051 E ROY ST 90042

Application / Permit
24014-10000-04317
Plan Check / Job No.
B24LA24299
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Eplan. New Two-story ground floor addition to (E) SFD
Permit Issued
Issued on 4/16/2025
Issuing Office
Current Status
Issued on 4/16/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/24/2024 APPLICANT
Assigned to Plan Check Engineer 10/3/2024 GEORGE JOLAKIAN
Corrections Issued 10/10/2024 GEORGE JOLAKIAN
Quality Review Completed 10/11/2024 RODOLFO ARIAS
Plan Check Approved 4/15/2025 GEORGE JOLAKIAN
Issued 4/16/2025 APPLICANT

Permit Application Clearance Information

Grading Pre-Inspection Cleared 1/30/2025 GEORGE JOLAKIAN
BHO/Hillside ordinance Cleared 2/4/2025 DAVID LOPEZ
BHO/Hillside ordinance Cleared 2/4/2025 DAVID LOPEZ
Permit Cleared 2/4/2025 DAVID LOPEZ
Roof/Waste drainage to street Cleared 2/4/2025 DAVID LOPEZ
Sewer availability Cleared 2/4/2025 DAVID LOPEZ
Eng Process Fee Ord 176,300 Cleared 2/6/2025 DAVID LOPEZ

Contact Information

Contractor Owner-Builder       ,
Engineer Bayani-Rad,, Padra; Lic. No.: C86320 15901 HAWTHORNE BLVD UNIT 220      LAWNDALE, CA 90260
Geologist Triebold,, Mark John; Lic. No.: EG1796 6906 QUITO COURT      CAMARILLO, CA 93012

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

ELECTRICAL-Rough 4/23/2025 Not Ready for Inspection DAVID WILLIAMS
Underground Mechanical 4/23/2025 Approved DAVID WILLIAMS
Excavation/Setback/Form/Re-Bar 5/7/2025 Approved DAVID WILLIAMS
Deputy Drilled-In Anchors 5/8/2025 Conditional Approval DAVID WILLIAMS
Deputy Other (see comments) 5/8/2025 Conditional Approval DAVID WILLIAMS
BUILDING-Rough-Frame 6/16/2025 Approved DAVID WILLIAMS
Floor/Roof Diaphrgm/Shear Wall 6/16/2025 Approved DAVID WILLIAMS
Green Building Rough 6/16/2025 Approved DAVID WILLIAMS
Rough-Elec/Plmb/HVAC 6/16/2025 Approved DAVID WILLIAMS
Insulation 6/18/2025 Corrections Issued LILIANA PORTILLO
Insulation 6/27/2025 Partial Approval REGINA MENDEZ
Interior/Exterior Lathing 6/27/2025 Partial Approval REGINA MENDEZ
Drywall Nailing 7/21/2025 Not Ready for Inspection ANTHONY RAMOS
Green Building Rough 7/30/2025 Approved DAVID WILLIAMS
Interior/Exterior Lathing 8/25/2025 Approved DAVID WILLIAMS
Shower Pan 8/25/2025 Approved DAVID WILLIAMS
Drywall Nailing 11/13/2025 Approved DAVID WILLIAMS
Final 11/13/2025 Corrections Issued DAVID WILLIAMS
Footing/Foundation/Slab 11/13/2025 Approved DAVID WILLIAMS
Green Building Final 11/13/2025 Approved DAVID WILLIAMS
SGSOV-Seismic Gas S/O Valve 11/13/2025 SGSOV Approved DAVID WILLIAMS
Smoke Detectors 11/13/2025 Approved DAVID WILLIAMS
Final 1/22/2026 Corrections Issued DAVID WILLIAMS