1351 1/2 W 71ST ST 90044

Certificate Information: 1351 1/2 W 71ST ST 90044

Application / Permit
24014-10000-02871
Plan Check / Job No.
B24LA12556
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
E-plan. (E) Garage of 324 Sq. Ft. to be converted into an ADU and an addition of 126 Sq. Ft. total ADU area 450 Sq. Ft. per LAMC 12.22 A.33(c)-(d) R3 occupancy
Permit Issued
Issued on 6/24/2025
Issuing Office
Current Status
CofO Issued on 1/14/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/9/2024 APPLICANT
Assigned to Plan Check Engineer 7/12/2024 SAMUEL GONZALEZ
Corrections Issued 7/13/2024 SAMUEL GONZALEZ
Applicant returned to address corrections 10/9/2024 SAMUEL GONZALEZ
Applicant returned to address corrections 10/24/2024 SAMUEL GONZALEZ
Plan Check Approved 10/29/2024 KELVIN CHUONG
Issued 6/24/2025 APPLICANT
CofO in Progress 1/13/2026 BARRY HACHE
Permit Finaled 1/14/2026 DEROLD HAUFF
Permit Finaled 1/14/2026 DEROLD HAUFF
CofO Issued 1/14/2026 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 9/4/2024 CELINA MORENO
Roof/Waste drainage to street Cleared 9/4/2024 CELINA MORENO
Eng Process Fee Ord 176,300 Cleared 9/6/2024 CELINA MORENO
Sewer availability Cleared 9/6/2024 CELINA MORENO

Contact Information

Contractor Pure Passion Builders Inc; Lic. No.: 1102664-B       ,

Inspector Information

BARRY HACHE, (213) 202-9851 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/1/2025 Corrections Issued BARRY HACHE
Footing/Foundation/Slab 7/10/2025 Corrections Issued BARRY HACHE
Underground Mechanical 7/29/2025 Partial Approval RONNIE MEDINA
Footing/Foundation/Slab 8/4/2025 Corrections Issued BARRY HACHE
Underground Mechanical 8/4/2025 Not Ready for Inspection BARRY HACHE
Footing/Foundation/Slab 8/8/2025 Corrections Issued BARRY HACHE
Excavation/Setback/Form/Re-Bar 8/14/2025 Approved BARRY HACHE
ELECTRICAL-Rough 8/20/2025 Corrections Issued BARRY HACHE
Floor/Roof Diaphrgm/Shear Wall 8/20/2025 Corrections Issued BARRY HACHE
HVAC-Rough 8/20/2025 Corrections Issued BARRY HACHE
PLUMBING-Rough 8/20/2025 Corrections Issued BARRY HACHE
Floor/Roof Diaphrgm/Shear Wall 8/26/2025 Approved BARRY HACHE
HVAC-Rough 8/26/2025 Approved BARRY HACHE
Rough-Elec/Plmb/HVAC 8/26/2025 Approved BARRY HACHE
BUILDING-Rough-Frame 9/3/2025 Approved BARRY HACHE
Green Building Rough 9/3/2025 Approved BARRY HACHE
Interior/Exterior Lathing 9/3/2025 Approved BARRY HACHE
Insulation 9/5/2025 Partial Inspection RAUL BARAJAS
Drywall Nailing 9/10/2025 Approved BARRY HACHE
Interior/Exterior Lathing 9/10/2025 Not Ready for Inspection BARRY HACHE
Shower Pan 9/10/2025 Not Ready for Inspection BARRY HACHE
Interior/Exterior Lathing 9/17/2025 Approved BARRY HACHE
Shower Pan 9/17/2025 Corrections Issued BARRY HACHE
Shower Pan 9/18/2025 Corrections Issued BARRY HACHE
Shower Pan 9/22/2025 Approved BARRY HACHE
Sewer 10/28/2025 Approved BARRY HACHE
Underground Mechanical 10/28/2025 Not Ready for Inspection BARRY HACHE
Underground Mechanical 10/31/2025 Approved ALEX COLIN
ELECTRICAL-Final 11/20/2025 Corrections Issued BARRY HACHE
Final 11/20/2025 Corrections Issued BARRY HACHE
Footing/Foundation/Slab 11/20/2025 Approved BARRY HACHE
Green Building Final 11/20/2025 Corrections Issued BARRY HACHE
HVAC-Final 11/20/2025 Not Ready for Inspection BARRY HACHE
PLUMBING-Final 11/20/2025 Corrections Issued BARRY HACHE
ELECTRICAL-Final 12/5/2025 Not Ready for Inspection BARRY HACHE
Final 12/5/2025 Not Ready for Inspection BARRY HACHE
Green Building Final 12/5/2025 Not Ready for Inspection BARRY HACHE
HVAC-Final 12/5/2025 Corrections Issued BARRY HACHE
PLUMBING-Final 12/5/2025 Corrections Issued BARRY HACHE
SGSOV-Seismic Gas S/O Valve 12/5/2025 SGSOV Approved BARRY HACHE
Smoke Detectors 12/5/2025 Approved BARRY HACHE
ELECTRICAL-Final 1/8/2026 Approved BARRY HACHE
Final 1/8/2026 Corrections Issued BARRY HACHE
Green Building Final 1/8/2026 Not Ready for Inspection BARRY HACHE
HVAC-Final 1/8/2026 Approved BARRY HACHE
PLUMBING-Final 1/8/2026 Approved BARRY HACHE
Final 1/12/2026 Not Ready for Inspection BARRY HACHE
Green Building Final 1/12/2026 Approved BARRY HACHE
Final 1/13/2026 OK to Issue CofO BARRY HACHE