6010 N LASAINE AVE 91316

Certificate Information: 6010 N LASAINE AVE 91316

Application / Permit
24014-10000-02799
Plan Check / Job No.
B24LA12261
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PROPOSED ADDITION AND MAJOR REMODEL TO (E) SINGLE FAMILY DWELLING. BLDG TO BE EQUIPPED WITH AUTOMATIC SPRINKLERS SYSTEM NFPA-13D.
Permit Issued
Issued on 1/25/2025
Issuing Office
Current Status
CofO Issued on 4/25/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/26/2024 APPLICANT
Assigned to Plan Check Engineer 6/27/2024 ARMEN JIVALAGIAN
Corrections Issued 7/2/2024 ARMEN JIVALAGIAN
Quality Review Completed 7/3/2024 PETER KIM
Applicant returned to address corrections 8/30/2024 ARMEN JIVALAGIAN
Plan Check Approved 1/24/2025 ARMEN JIVALAGIAN
Issued 1/25/2025 APPLICANT
CofO in Progress 9/8/2025 MORRIS JACKSON
Permit Finaled 4/25/2026 MICHAEL PELHAM
CofO Issued 4/25/2026 MICHAEL PELHAM
Permit Finaled 4/25/2026 MICHAEL PELHAM

Permit Application Clearance Information

Low Impact Development (LID) Cleared 8/21/2024 MARCO SANCHEZ
Roof/Waste drainage to street Cleared 9/17/2024 BIAINA HARITUNIAN
Sewer availability Cleared 9/17/2024 BIAINA HARITUNIAN
ZI Cleared 9/18/2024 ASHLEY RODARTE
Eng Process Fee Ord 176,300 Cleared 1/19/2025 BIAINA HARITUNIAN

Contact Information

Contractor Owner-Builder       ,
Engineer Yenjai,, Seree; Lic. No.: C73151 3249 SHADYLAWN DRIVE      DUARTE, CA 91010

Inspector Information

JON MCHUGH, (818) 774-4348 Office Hours: 7:00-8:00 AM MON-FRI
IVAN SARABIA, (818) 774-4348 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 2/21/2025 Conditional Approval MORRIS JACKSON
Excavation/Setback/Form/Re-Bar 2/21/2025 Not Ready for Inspection MORRIS JACKSON
Footing/Foundation/Slab 2/21/2025 Corrections Issued MORRIS JACKSON
Footing/Foundation/Slab 2/26/2025 Approved JON MCHUGH
Deputy Reinf. Concrete 2/27/2025 Conditional Approval JON MCHUGH
Floor/Roof Diaphrgm/Shear Wall 3/6/2025 Partial Approval MORRIS JACKSON
PLUMBING-Rough 3/6/2025 Partial Approval MORRIS JACKSON
Underground Mechanical 3/6/2025 Partial Approval MORRIS JACKSON
Insulation 3/7/2025 Partial Approval MORRIS JACKSON
Floor/Roof Diaphrgm/Shear Wall 3/10/2025 Partial Approval MORRIS JACKSON
Floor/Roof Diaphrgm/Shear Wall 4/3/2025 Partial Approval MORRIS JACKSON
Green Building Rough 4/3/2025 Not Ready for Inspection MORRIS JACKSON
BUILDING-Rough-Frame 4/10/2025 Corrections Issued JON MCHUGH
Green Building Rough 4/10/2025 Not Ready for Inspection JON MCHUGH
Rough-Elec/Plmb/HVAC 4/10/2025 Corrections Issued JON MCHUGH
ELECTRICAL-Rough 4/16/2025 Approved MORRIS JACKSON
Floor/Roof Diaphrgm/Shear Wall 4/16/2025 Partial Approval MORRIS JACKSON
Gas Test 4/16/2025 Approved MORRIS JACKSON
HVAC-Rough 4/16/2025 Approved MORRIS JACKSON
PLUMBING-Rough 4/16/2025 Approved MORRIS JACKSON
BUILDING-Rough-Frame 4/24/2025 Approved MORRIS JACKSON
Green Building Rough 4/24/2025 Approved MORRIS JACKSON
Interior/Exterior Lathing 4/24/2025 Partial Approval MORRIS JACKSON
Shower Pan 4/24/2025 Approved MORRIS JACKSON
Verify Sprinkler Sign Off 4/24/2025 Approved MORRIS JACKSON
Insulation 4/29/2025 Approved MORRIS JACKSON
Interior/Exterior Lathing 4/29/2025 Approved MORRIS JACKSON
Drywall Nailing 5/6/2025 Approved MORRIS JACKSON
Pre-Inspection 6/10/2025 Partial Inspection MORRIS JACKSON
ELECTRICAL-Final 7/28/2025 Approved MORRIS JACKSON
Service/Power Release 7/28/2025 Not Ready for Inspection MORRIS JACKSON
Final 8/7/2025 Corrections Issued MORRIS JACKSON
Green Building Final 8/7/2025 Approved MORRIS JACKSON
SGSOV-Seismic Gas S/O Valve 8/7/2025 SGSOV Approved MORRIS JACKSON
Service/Power Release 8/7/2025 Approved MORRIS JACKSON
Smoke Detectors 8/7/2025 Approved MORRIS JACKSON
Final 8/26/2025 OK to Issue CofO MORRIS JACKSON