3253 S BARRY AVE 90066
Certificate Information: 3253 S BARRY AVE 90066
- Application / Permit
- 24014-10000-02581
- Plan Check / Job No.
- B24LA09480
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- EPLAN ADDITION AND CONVERSION TO (E) 1-STORY TWO CAR GARAGE WITH RECROOM AND ATTACHED PATIO COVER TO BECOME A TWO STORY ACCESSORY DWELLING UNIT WITH 1-CAR GARAGE TO REMAIN ADU PER LAMC 12.22 A.33(c)-(d)
- Permit Issued
- Issued on 7/28/2025
- Issuing Office
- Current Status
- Issued on 7/28/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 5/21/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 6/6/2024 | JAD BASMA |
| Corrections Issued | 6/12/2024 | JAD BASMA |
| Quality Review Completed | 7/5/2024 | GARO TELMI |
| Applicant returned to address corrections | 5/7/2025 | JAD BASMA |
| Applicant returned to address corrections | 7/9/2025 | JAD BASMA |
| Plan Check Approved | 7/22/2025 | JAD BASMA |
| Issued | 7/28/2025 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 7/29/2024 | DARIN LAM |
| Roof/Waste drainage to street | Cleared | 7/29/2024 | DARIN LAM |
| Eng Process Fee Ord 176,300 | Cleared | 3/25/2025 | DARIN LAM |
| Sewer availability | Cleared | 3/25/2025 | DARIN LAM |
| Specific Plan | Cleared | 6/10/2025 | JOSHUA JONES |
| GPI Written Notices | Cleared | 7/22/2025 | JAD BASMA |
| Grading Pre-Inspection | Cleared | 7/22/2025 | JAD BASMA |
Contact Information
| Contractor | Pure Builders Inc; Lic. No.: 757470-B | , |
Inspector Information
| KIRK SANDERS, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
| ARAM AVEDISIAN, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 9/9/2025 | Partial Approval | KIRK SANDERS |
| Excavation/Setback/Form/Re-Bar | 9/23/2025 | Approved | MICHAEL ALLEN |
| Footing/Foundation/Slab | 9/23/2025 | Approved | MICHAEL ALLEN |
| BUILDING-Rough-Frame | 10/15/2025 | Corrections Issued | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/15/2025 | Conditional Approval | KIRK SANDERS |
| Special/Order Compliance | 10/15/2025 | Corrections Issued | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 11/12/2025 | Conditional Approval | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 12/9/2025 | Partial Approval | EUGENE CASSIDY |
| Wood Frame | 12/9/2025 | Not Ready for Inspection | EUGENE CASSIDY |
| Floor/Roof Diaphrgm/Shear Wall | 1/26/2026 | Conditional Approval | ARAM AVEDISIAN |
| PLUMBING-Rough | 1/29/2026 | Approved | ARAM AVEDISIAN |
| ELECTRICAL-Rough | 2/25/2026 | Approved | ARAM AVEDISIAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/13/2026 | Approved | JESUS PINEDA |
| Shower Pan | 3/19/2026 | Approved | RYAN SALAZAR |
| Interior/Exterior Lathing | 4/2/2026 | Partial Approval | EUGENE CASSIDY |
| HVAC-Rough | 4/7/2026 | Approved | JESUS PINEDA |
| BUILDING-Rough-Frame | 4/13/2026 | Approved | MICHAEL ALLEN |
| Green Building Rough | 4/13/2026 | Approved | MICHAEL ALLEN |
| Interior/Exterior Lathing | 4/21/2026 | Approved | ANDREW NAVE |
| Insulation | 4/29/2026 | Approved | EUGENE CASSIDY |
| Drywall Nailing | 5/12/2026 | Approved | ANDREW NAVE |