110 W 97TH ST 90003

Certificate Information: 110 W 97TH ST 90003

Application / Permit
24014-10000-02518
Plan Check / Job No.
B24LA11082
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
Eplan Convert detached garage with addition to ADU per ordinance
Permit Issued
Issued on 8/15/2024
Issuing Office
Current Status
CofO Issued on 5/1/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/13/2024 APPLICANT
Assigned to Plan Check Engineer 6/20/2024 MINA HABILI
Corrections Issued 6/21/2024 MINA HABILI
Plan Check Approved 7/26/2024 FERNANDO FLORES
Issued 8/15/2024 APPLICANT
CofO in Progress 4/29/2025 BEN MOLSTAD
Permit Finaled 5/1/2025 ANSON MAGLASANG
CofO Issued 5/1/2025 ANSON MAGLASANG
Permit Finaled 5/1/2025 ANSON MAGLASANG

Permit Application Clearance Information

Address approval Cleared 6/24/2024 TREVOR QUAN
Eng Process Fee Ord 176,300 Cleared 6/26/2024 TREVOR QUAN
Sewer availability Cleared 6/26/2024 TREVOR QUAN
Construction near power lines Cleared 7/3/2024 EDGAR PASCUA
Roof/Waste drainage to street Cleared 7/24/2024 CELINA MORENO

Contact Information

Contractor Mdr Builders; Lic. No.: 741228-B       ,
Engineer Madero,, Fidencio; Lic. No.: C81695 PO BOX 40237      DOWNEY, CA 90239

Inspector Information

JOHN KLARIN, (310) 732-4558 Office Hours: 7:00-8:00 AM MON-FRI
ARTHUR NEGRETE, (310) 732-4558 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 9/4/2024 Partial Approval BEN MOLSTAD
PLUMBING-Rough 9/4/2024 Corrections Issued BEN MOLSTAD
Underground Mechanical 9/4/2024 Not Ready for Inspection BEN MOLSTAD
Deputy Drilled-In Anchors 9/12/2024 Conditional Approval ANSON MAGLASANG
Excavation/Setback/Form/Re-Bar 9/12/2024 Approved ANSON MAGLASANG
Underground Mechanical 9/12/2024 Approved ANSON MAGLASANG
Floor/Roof Diaphrgm/Shear Wall 10/4/2024 Approved BARRY HACHE
ELECTRICAL-Rough 12/17/2024 Corrections Issued BEN MOLSTAD
HVAC-Rough 12/17/2024 Corrections Issued BEN MOLSTAD
PLUMBING-Rough 12/17/2024 Approved BEN MOLSTAD
BUILDING-Rough-Frame 12/23/2024 Conditional Approval JOSEPH MCGARRY
ELECTRICAL-Rough 12/23/2024 Approved JOSEPH MCGARRY
Green Building Rough 12/23/2024 Approved JOSEPH MCGARRY
HVAC-Rough 12/23/2024 Conditional Approval JOSEPH MCGARRY
Insulation 12/30/2024 Approved BEN MOLSTAD
Drywall Nailing 1/15/2025 Approved BEN MOLSTAD
Interior/Exterior Lathing 1/15/2025 Partial Approval BEN MOLSTAD
SGSOV-Seismic Gas S/O Valve 3/27/2025 SGSOV Not Ready ANTHONY EGSON
Final 3/28/2025 Corrections Issued BEN MOLSTAD
Special/Order Compliance 3/28/2025 Not Ready for Inspection BEN MOLSTAD
BUILDING-Rough-Frame 4/1/2025 Approved BEN MOLSTAD
Final 4/1/2025 Corrections Issued BEN MOLSTAD
Footing/Foundation/Slab 4/1/2025 Approved BEN MOLSTAD
Green Building Final 4/1/2025 Not Ready for Inspection BEN MOLSTAD
SGSOV-Seismic Gas S/O Valve 4/1/2025 SGSOV Not Ready BEN MOLSTAD
Smoke Detectors 4/1/2025 Approved BEN MOLSTAD
ELECTRICAL-Final 4/9/2025 Approved BEN MOLSTAD
Final 4/9/2025 OK to Issue CofO BEN MOLSTAD
Green Building Final 4/9/2025 Approved BEN MOLSTAD
HVAC-Final 4/9/2025 Approved BEN MOLSTAD
PLUMBING-Final 4/9/2025 Approved BEN MOLSTAD
SGSOV-Seismic Gas S/O Valve 4/9/2025 SGSOV Approved BEN MOLSTAD
Service/Power Release 4/9/2025 Approved BEN MOLSTAD