209 S AVENUE 59 90042

Certificate Information: 209 S AVENUE 59 90042

Application / Permit
24014-10000-02477
Plan Check / Job No.
B24LA10916
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(7) Garage - Private
Work Description
ePlan: New detached garage with covered porch. COMPLY WITH DEPARTMENT ORDER effective date 04/29/2024. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE. CEIS Case Number is 1004172. ***SEE COMMENTS***
Permit Issued
Issued on 10/15/2024
Issuing Office
Current Status
Issued on 10/15/2024
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 6/7/2024 APPLICANT
Assigned to Plan Check Engineer 6/12/2024 AMY GUEVARRA
Corrections Issued 6/17/2024 AMY GUEVARRA
Applicant returned to address corrections 9/10/2024 CAROLEAN BASMA
Applicant returned to address corrections 9/13/2024 CAROLEAN BASMA
Applicant returned to address corrections 9/25/2024 CAROLEAN BASMA
Plan Check Approved 10/14/2024 CAROLEAN BASMA
Issued 10/15/2024 APPLICANT

Permit Application Clearance Information

Address approval Cleared 6/25/2024 DAVID LOPEZ
Roof/Waste drainage to street Cleared 6/25/2024 DAVID LOPEZ
CPC Cleared 7/1/2024 SPENCER WEJROWSKI
Eng Process Fee Ord 176,300 Cleared 7/8/2024 DAVID LOPEZ
Sewer availability Cleared 7/8/2024 DAVID LOPEZ
HPOZ Cleared 9/3/2024 NATHALY DE LA PAZ
Grading Pre-Inspection Cleared 9/26/2024 AMY GUEVARRA
HPOZ Cleared 10/9/2024 NATHALY DE LA PAZ

Contact Information

Contractor Worman Construction Corp; Lic. No.: 989832-B       ,
Engineer Melchor,, Oscar Elias; Lic. No.: NA76828       ,

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

BUILDING-Rough-Frame 11/7/2024 Not Ready for Inspection FERMIN RUBIO
ELECTRICAL-Rough 11/7/2024 Partial Approval FERMIN RUBIO
Footing/Foundation/Slab 11/7/2024 Not Ready for Inspection FERMIN RUBIO
Green Building Rough 11/7/2024 Not Ready for Inspection FERMIN RUBIO
MERV13>=Rough 11/7/2024 Approved FERMIN RUBIO
PLUMBING-Rough 11/7/2024 Not Ready for Inspection FERMIN RUBIO
Wood Frame 11/7/2024 Not Ready for Inspection FERMIN RUBIO
Interior/Exterior Lathing 11/13/2024 Corrections Issued JACOB SEGURA
Footing/Foundation/Slab 11/21/2024 Not Ready for Inspection JACOB SEGURA
BUILDING-Rough-Frame 3/13/2025 Corrections Issued JACOB SEGURA
Drywall Nailing 3/13/2025 Not Ready for Inspection JACOB SEGURA
Final 3/13/2025 Not Ready for Inspection JACOB SEGURA
Footing/Foundation/Slab 3/13/2025 Corrections Issued JACOB SEGURA
Green Building Final 3/13/2025 Not Ready for Inspection JACOB SEGURA
Green Building Rough 3/13/2025 Not Ready for Inspection JACOB SEGURA
MERV13>=Final 3/13/2025 Not Ready for Inspection JACOB SEGURA
SGSOV-Seismic Gas S/O Valve 3/13/2025 SGSOV Not Ready JACOB SEGURA
Service/Power Release 3/13/2025 Not Ready for Inspection JACOB SEGURA
Smoke Detectors 3/13/2025 Not Ready for Inspection JACOB SEGURA