2848 3/4 S BUCKINGHAM ROAD 90016

Certificate Information: 2848 3/4 S BUCKINGHAM ROAD 90016

Application / Permit
24014-10000-02236
Plan Check / Job No.
B24LA09936
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
15'-3" X 26'-6" ADDITION AND CONVERT EXISTING DETACHED GARAGE INTO TWO ACCESSORY DWELLING UNITS PER GCS 65852.2(e)(1)(D) AND (g) LAMC 12.22 A.33(c), (d), and (g). WORK PER ENGINEERED DESIGN.
Permit Issued
Issued on 1/30/2025
Issuing Office
Current Status
Issued on 1/30/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 5/24/2024 APPLICANT
Assigned to Plan Check Engineer 5/31/2024 OMAR GARNICA
Corrections Issued 5/31/2024 OMAR GARNICA
Plan Check Approved 1/22/2025 DANIEL ABRAMYAN
Issued 1/30/2025 APPLICANT

Permit Application Clearance Information

Construction near power lines Cleared 11/25/2024 RIDWAN HARDY
Address approval Cleared 12/11/2024 WALLIE JONG
Roof/Waste drainage to street Cleared 12/11/2024 WALLIE JONG
Eng Process Fee Ord 176,300 Cleared 12/26/2024 WALLIE JONG
Sewer availability Cleared 12/26/2024 WALLIE JONG
Flood clearance Cleared 1/14/2025 TUYEN LE

Contact Information

Contractor Owner-Builder       ,
Engineer Chiu,, Ivan Wai-Kuen; Lic. No.: C44672 2160 PARNELL WY      ALTADENA, CA 91001

Inspector Information

JUSTIN HAWLEY, (213) 202-3432 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 10/15/2025 Partial Approval JUSTIN HAWLEY
Footing/Foundation/Slab 11/4/2025 Corrections Issued JUSTIN HAWLEY
Excavation/Setback/Form/Re-Bar 11/10/2025 Approved JUSTIN HAWLEY
Footing/Foundation/Slab 11/14/2025 Approved JUSTIN HAWLEY
Floor/Roof Diaphrgm/Shear Wall 3/3/2026 Approved JUSTIN HAWLEY
Gas Test 3/3/2026 Approved JUSTIN HAWLEY
Rough-Elec/Plmb/HVAC 3/3/2026 Corrections Issued JUSTIN HAWLEY
Underground Mechanical 3/3/2026 Partial Approval JUSTIN HAWLEY
BUILDING-Rough-Frame 3/18/2026 Approved WILLIAM SIERRA
Green Building Rough 3/18/2026 Approved WILLIAM SIERRA
HVAC-Rough 3/18/2026 Approved WILLIAM SIERRA
Interior/Exterior Lathing 3/18/2026 Partial Approval WILLIAM SIERRA
Rough-Elec/Plmb/HVAC 3/18/2026 Approved WILLIAM SIERRA
Insulation 3/25/2026 Corrections Issued JUSTIN HAWLEY
Drywall Nailing 4/3/2026 Approved JUSTIN HAWLEY
Insulation 4/3/2026 Approved JUSTIN HAWLEY
Shower Pan 4/17/2026 Approved JUSTIN HAWLEY
Interior/Exterior Lathing 4/29/2026 Approved JUSTIN HAWLEY