1550-1550 1/2 E 109TH ST 90059

Certificate Information: 1550-1550 1/2 E 109TH ST 90059

Application / Permit
24014-10000-01835
Plan Check / Job No.
B24LA08230
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
Conversion and addition to (e) 2 car garage and 2 car carport to create a 2 story 2 new adus per GCS 65852.2(e)(1)(D) and LAMC 12.22A.33(c)(d) and (g). To be fully sprinklered NFPA 13D
Permit Issued
Issued on 12/17/2024
Issuing Office
Metro
Current Status
Issued on 12/17/2024
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 5/2/2024 APPLICANT
Assigned to Plan Check Engineer 5/16/2024 MARCELA FRANQUEZ
Corrections Issued 5/21/2024 MARCELA FRANQUEZ
Quality Review Completed 5/24/2024 KEN GILL
Building Plans Picked Up 5/31/2024 APPLICANT
Plan Check Approved 12/16/2024 MARCELA FRANQUEZ
Issued 12/17/2024 APPLICANT

Permit Application Clearance Information

Address approval Cleared 8/6/2024 CELINA MORENO
Eng Process Fee Ord 176,300 Cleared 9/24/2024 CELINA MORENO
Roof/Waste drainage to street Cleared 9/27/2024 CELINA MORENO
Sewer availability Cleared 10/4/2024 CELINA MORENO
Hydrant and Access approval Cleared 12/11/2024 KURT CORRAL

Contact Information

Contractor De La Rosa Construction; Lic. No.: 855010-B 3627 E FIRST STREET      LOS ANGELES, CA 90063
Engineer Castillo,, Margarito; Lic. No.: S4808 1205 PINE AVE   SUITE 201    LONG BEACH, CA 90813

Inspector Information

JOHN KLARIN, (310) 732-4558 Office Hours: 7:00-8:00 AM MON-FRI
ARTHUR NEGRETE, (310) 732-4558 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 1/10/2025 Partial Approval ANTHONY EGSON
Underground Mechanical 1/10/2025 Partial Approval ANTHONY EGSON
Deputy Drilled-In Anchors 1/14/2025 Conditional Approval ANTHONY EGSON
Excavation/Setback/Form/Re-Bar 1/15/2025 Approved ANTHONY EGSON
Footing/Foundation/Slab 1/15/2025 Corrections Issued ANTHONY EGSON
Deputy Drilled-In Anchors 1/16/2025 Partial Approval ANSON MAGLASANG
Excavation/Setback/Form/Re-Bar 1/16/2025 Approved ANTHONY EGSON
Footing/Foundation/Slab 1/16/2025 Approved ANTHONY EGSON
Order to Comply 1/16/2025 Not Required ANTHONY EGSON
Floor/Roof Diaphrgm/Shear Wall 2/12/2025 Partial Approval JOSEPH MCGARRY
Floor/Roof Diaphrgm/Shear Wall 3/4/2025 Approved ANTHONY EGSON
ELECTRICAL-Rough 6/6/2025 Not Ready for Inspection EUGENE CASSIDY
HVAC-Rough 6/6/2025 Corrections Issued EUGENE CASSIDY
PLUMBING-Rough 6/6/2025 Partial Approval EUGENE CASSIDY
ELECTRICAL-Rough 6/23/2025 Corrections Issued ANTHONY EGSON
HVAC-Rough 6/23/2025 Corrections Issued ANTHONY EGSON
Interior/Exterior Lathing 6/23/2025 Approved ANTHONY EGSON
PLUMBING-Rough 6/23/2025 Corrections Issued ANTHONY EGSON
ELECTRICAL-Rough 7/3/2025 Approved ANTHONY EGSON
HVAC-Rough 7/3/2025 Not Ready for Inspection ANTHONY EGSON
PLUMBING-Rough 7/3/2025 Not Ready for Inspection ANTHONY EGSON
Insulation 8/1/2025 Corrections Issued ANTHONY EGSON
Sewer 8/1/2025 Approved ANTHONY EGSON
Floor/Roof Diaphrgm/Shear Wall 8/8/2025 Approved ANTHONY EGSON
Underground Mechanical 8/8/2025 Partial Approval ANTHONY EGSON
Insulation 8/29/2025 Not Ready for Inspection ANSON MAGLASANG
Insulation 9/3/2025 Not Ready for Inspection ANTHONY EGSON
Drywall Nailing 9/10/2025 Partial Approval ANTHONY EGSON
Green Building Rough 9/10/2025 Approved ANTHONY EGSON
Insulation 9/10/2025 Approved ANTHONY EGSON
Drywall Nailing 9/15/2025 Conditional Approval EUGENE CASSIDY
Gas Test 10/31/2025 Approved ANTHONY EGSON
Interior/Exterior Lathing 11/10/2025 Approved ANTHONY EGSON
SGSOV-Seismic Gas S/O Valve 12/24/2025 SGSOV Not Ready ARTHUR NEGRETE
BUILDING-Rough-Frame 1/9/2026 Approved ARTHUR NEGRETE
Drywall Nailing 1/9/2026 Approved ARTHUR NEGRETE
ELECTRICAL-Final 1/9/2026 Approved ARTHUR NEGRETE
Final 1/9/2026 Partial Inspection ARTHUR NEGRETE
Green Building Final 1/9/2026 Not Ready for Inspection ARTHUR NEGRETE
PLUMBING-Final 1/9/2026 Approved ARTHUR NEGRETE
SGSOV-Seismic Gas S/O Valve 1/9/2026 SGSOV Approved ARTHUR NEGRETE
Smoke Detectors 1/9/2026 Approved ARTHUR NEGRETE
Final 1/27/2026 Corrections Issued ARTHUR NEGRETE
Green Building Final 1/27/2026 Approved ARTHUR NEGRETE
Service/Power Release 1/27/2026 Not Ready for Inspection ARTHUR NEGRETE
Final 2/3/2026 Not Ready for Inspection ARTHUR NEGRETE
HVAC-Final 2/3/2026 Approved ARTHUR NEGRETE
Service/Power Release 2/3/2026 Approved ARTHUR NEGRETE
Special/Order Compliance 3/19/2026 Corrections Issued ARTHUR NEGRETE
Pre-Inspection 3/20/2026 Approved ARTHUR NEGRETE