2203 S SYCAMORE AVE 90016
Certificate Information: 2203 S SYCAMORE AVE 90016
- Application / Permit
- 24014-10000-00757
- Plan Check / Job No.
- B24LA03410
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- EPLAN second floor addition and Two-story ground floor addition to (E) one story SFD fire sprinkler NFDP-13D
- Permit Issued
- Issued on 10/4/2024
- Issuing Office
- Current Status
- CofO Corrected on 1/12/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 2/28/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 3/14/2024 | GEORGE JOLAKIAN |
| Corrections Issued | 3/27/2024 | GEORGE JOLAKIAN |
| Quality Review Completed | 4/9/2024 | RODOLFO ARIAS |
| Plan Check Approved | 9/26/2024 | GEORGE JOLAKIAN |
| Issued | 10/4/2024 | APPLICANT |
| CofO in Progress | 9/5/2025 | JUSTIN HAWLEY |
| CofO Issued-Status Void | 9/8/2025 | DEROLD HAUFF |
| Permit Finaled-Status Void | 9/8/2025 | DEROLD HAUFF |
| Re-Activate Permit | 1/8/2026 | DEROLD HAUFF |
| Permit Finaled | 1/12/2026 | DEROLD HAUFF |
| CofO Corrected | 1/12/2026 | DEROLD HAUFF |
| Permit Finaled | 1/12/2026 | DEROLD HAUFF |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 4/5/2024 | DAVID LOPEZ |
| Sewer availability | Cleared | 4/5/2024 | DAVID LOPEZ |
| Eng Process Fee Ord 176,300 | Cleared | 4/9/2024 | DAVID LOPEZ |
Contact Information
| Contractor | 7 Day Builders Inc; Lic. No.: 1106832-B | , |
| Engineer | Cooke,, Conway Cecil; Lic. No.: NA5524 | , |
Inspector Information
| JUSTIN HAWLEY, (213) 202-3432 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 10/21/2024 | Partial Approval | JUSTIN HAWLEY |
| Underground Mechanical | 10/21/2024 | Partial Approval | JUSTIN HAWLEY |
| Deputy Drilled-In Anchors | 10/31/2024 | Conditional Approval | ANTHONY RAMOS |
| Footing/Foundation/Slab | 10/31/2024 | Partial Approval | BRENDAN MORELLI |
| BUILDING-Rough-Frame | 11/20/2024 | Not Ready for Inspection | BRENDAN MORELLI |
| Green Building Rough | 11/20/2024 | Not Ready for Inspection | BRENDAN MORELLI |
| Wood Frame | 11/20/2024 | Partial Approval | BRENDAN MORELLI |
| Floor/Roof Diaphrgm/Shear Wall | 11/22/2024 | Partial Approval | BRENDAN MORELLI |
| Insulation | 11/22/2024 | Partial Approval | BRENDAN MORELLI |
| Floor/Roof Diaphrgm/Shear Wall | 11/27/2024 | Partial Approval | JUSTIN HAWLEY |
| PLUMBING-Rough | 11/27/2024 | Not Ready for Inspection | JUSTIN HAWLEY |
| Floor/Roof Diaphrgm/Shear Wall | 12/2/2024 | Not Ready for Inspection | JUSTIN HAWLEY |
| Floor/Roof Diaphrgm/Shear Wall | 12/23/2024 | Not Ready for Inspection | JUSTIN HAWLEY |
| Floor/Roof Diaphrgm/Shear Wall | 12/24/2024 | Partial Approval | NICHOLAS LOPEZ |
| Deputy Drilled-In Anchors | 1/22/2025 | Conditional Approval | JUSTIN HAWLEY |
| Deputy Wood Construction | 1/22/2025 | Conditional Approval | JUSTIN HAWLEY |
| Floor/Roof Diaphrgm/Shear Wall | 1/30/2025 | Approved | JUSTIN HAWLEY |
| Green Building Rough | 1/30/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Rough-Elec/Plmb/HVAC | 1/30/2025 | Corrections Issued | JUSTIN HAWLEY |
| Verify Sprinkler Sign Off | 1/30/2025 | Approved | JUSTIN HAWLEY |
| BUILDING-Rough-Frame | 2/6/2025 | Approved | JUSTIN HAWLEY |
| Rough-Elec/Plmb/HVAC | 2/6/2025 | Approved | JUSTIN HAWLEY |
| Shower Pan | 2/6/2025 | Approved | JUSTIN HAWLEY |
| Deputy Wood Construction | 2/7/2025 | Conditional Approval | JUSTIN HAWLEY |
| Insulation | 2/12/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Insulation | 2/14/2025 | Approved | JUSTIN HAWLEY |
| Drywall Nailing | 2/19/2025 | Corrections Issued | NICHOLAS LOPEZ |
| Green Building Rough | 2/19/2025 | Approved | NICHOLAS LOPEZ |
| Drywall Nailing | 2/24/2025 | Approved | JOSH MEISTER |
| Interior/Exterior Lathing | 2/24/2025 | Approved | JOSH MEISTER |
| Interior/Exterior Lathing | 2/26/2025 | Approved | RONNIE MINDANAO |
| Final | 7/10/2025 | Corrections Issued | JUSTIN HAWLEY |
| Footing/Foundation/Slab | 7/10/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| Green Building Final | 7/10/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| SGSOV-Seismic Gas S/O Valve | 7/10/2025 | SGSOV Not Ready | JUSTIN HAWLEY |
| Smoke Detectors | 7/10/2025 | Not Ready for Inspection | JUSTIN HAWLEY |
| ELECTRICAL-Final | 9/5/2025 | Approved | JUSTIN HAWLEY |
| Final | 9/5/2025 | OK to Issue CofO | JUSTIN HAWLEY |
| Footing/Foundation/Slab | 9/5/2025 | Approved | JUSTIN HAWLEY |
| Green Building Final | 9/5/2025 | Approved | JUSTIN HAWLEY |
| HVAC-Final | 9/5/2025 | Approved | JUSTIN HAWLEY |
| PLUMBING-Final | 9/5/2025 | Approved | JUSTIN HAWLEY |
| SGSOV-Seismic Gas S/O Valve | 9/5/2025 | SGSOV Approved | JUSTIN HAWLEY |
| Service/Power Release | 9/5/2025 | Approved | JUSTIN HAWLEY |
| Smoke Detectors | 9/5/2025 | Approved | JUSTIN HAWLEY |