6154-6154 1/2 N COLBATH AVE 91401
Certificate Information: 6154-6154 1/2 N COLBATH AVE 91401
- Application / Permit
- 24010-20000-04072
- Plan Check / Job No.
- B24VN17744
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- [ePlan] NEW 2-STORY ADU PER CA Govt. Code 65852.2(e)(1)(A) AND A SFD UNDER SB 9 UNIT PER TWO UNIT DEVELOPMENT -BLDG SPINKLERED THRU-OUT
- Permit Issued
- Issued on 4/16/2025
- Issuing Office
- Current Status
- CofO Issued on 11/13/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/25/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 9/26/2024 | MAHNAZ NOURHASHEMI |
| Corrections Issued | 9/29/2024 | MAHNAZ NOURHASHEMI |
| Quality Review Completed | 10/9/2024 | TU HUA |
| Applicant returned to address corrections | 1/29/2025 | MAHNAZ NOURHASHEMI |
| Applicant returned to address corrections | 2/27/2025 | MAHNAZ NOURHASHEMI |
| Plan Check Approved | 4/15/2025 | MAHNAZ NOURHASHEMI |
| Issued | 4/16/2025 | APPLICANT |
| CofO in Progress | 9/16/2025 | RYAN SALAZAR |
| CofO Issued | 11/13/2025 | RUBEN SALAS |
| Permit Finaled | 11/13/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 10/7/2024 | RYAN CASTRO |
| Roof/Waste drainage to street | Cleared | 10/7/2024 | RYAN CASTRO |
| Eng Process Fee Ord 176,300 | Cleared | 10/8/2024 | RYAN CASTRO |
| Sewer availability | Cleared | 10/8/2024 | RYAN CASTRO |
| Hydrant and Access approval | Cleared | 1/2/2025 | JERRY KAO |
| Construction near power lines | Cleared | 4/4/2025 | GEVORK KARAPETYAN |
| Construction within easement | Cleared | 4/4/2025 | GEVORK KARAPETYAN |
| Senate Bill 9 | Cleared | 4/15/2025 | JASON CHAN |
Contact Information
| Contractor | Silva Design Construction Inc; Lic. No.: 956083-B | , |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 8232 GARVEY AVE 203 ROSEMEAD, CA 91770 |
Inspector Information
| JOSE AVILA, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
| VINCENT HANLEY, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 4/17/2025 | Partial Approval | RYAN SALAZAR |
| Footing/Foundation/Slab | 4/22/2025 | Approved | RYAN SALAZAR |
| Floor/Roof Diaphrgm/Shear Wall | 4/25/2025 | Off-Hour Fees Due | |
| Floor/Roof Diaphrgm/Shear Wall | 4/25/2025 | Partial Approval | RYAN SALAZAR |
| Floor/Roof Diaphrgm/Shear Wall | 4/30/2025 | Partial Approval | RYAN SALAZAR |
| Deputy Wood Construction | 5/1/2025 | Conditional Approval | JOAQUIN GREENOUGH |
| Floor/Roof Diaphrgm/Shear Wall | 5/5/2025 | Approved | RYAN SALAZAR |
| BUILDING-Rough-Frame | 5/12/2025 | Corrections Issued | RYAN SALAZAR |
| ELECTRICAL-Rough | 5/12/2025 | Approved | RYAN SALAZAR |
| HVAC-Rough | 5/12/2025 | Approved | RYAN SALAZAR |
| PLUMBING-Rough | 5/12/2025 | Conditional Approval | RYAN SALAZAR |
| Insulation | 5/19/2025 | Partial Approval | JACK KARGODORIAN |
| Insulation | 5/20/2025 | Approved | RYAN SALAZAR |
| Interior/Exterior Lathing | 5/20/2025 | Approved | RYAN SALAZAR |
| Shower Pan | 5/20/2025 | Approved | RYAN SALAZAR |
| Drywall Nailing | 5/22/2025 | Approved | RYAN SALAZAR |
| Sewer | 6/27/2025 | Approved | RYAN SALAZAR |
| BUILDING-Rough-Frame | 9/3/2025 | Approved | RYAN SALAZAR |
| Final | 9/3/2025 | Corrections Issued | RYAN SALAZAR |
| SGSOV-Seismic Gas S/O Valve | 9/3/2025 | SGSOV Not Required | RYAN SALAZAR |
| Service/Power Release | 9/3/2025 | Not Ready for Inspection | RYAN SALAZAR |
| Smoke Detectors | 9/3/2025 | Approved | RYAN SALAZAR |
| Verify Sprinkler Sign Off | 9/3/2025 | Approved | RYAN SALAZAR |
| Final | 9/15/2025 | OK to Issue CofO | RYAN SALAZAR |
| Service/Power Release | 9/15/2025 | Approved | RYAN SALAZAR |