10719 W SYLVAN ST 91606
Certificate Information: 10719 W SYLVAN ST 91606
- Application / Permit
- 24010-20000-03980
- Plan Check / Job No.
- B24VN17143
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 1-STORY DETACHED 23'-8" x 23'-3" ACCESSORY DWELLING UNIT TO COMPLY CA Govt. Code 65852.2(e)(1)(D) and applicable part2 of LAMC 12.22 A.33 (c)-(d), (g)
- Permit Issued
- Issued on 11/12/2024
- Issuing Office
- Current Status
- CofO Issued on 6/18/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/19/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 10/3/2024 | ALFRED RAMIREZ |
| Corrections Issued | 10/8/2024 | ALFRED RAMIREZ |
| Quality Review Completed | 10/15/2024 | STEVEN KIM |
| Building Plans Picked Up | 10/16/2024 | APPLICANT |
| Applicant returned to address corrections | 11/5/2024 | ALFRED RAMIREZ |
| Plan Check Approved | 11/12/2024 | ALFRED RAMIREZ |
| Issued | 11/12/2024 | APPLICANT |
| CofO in Progress | 5/30/2025 | ROBERTO PALACIOS-LOPEZ |
| CofO Issued | 6/18/2025 | RUBEN SALAS |
| Permit Finaled | 6/18/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 10/28/2024 | LEE GUILBEAUX |
| Roof/Waste drainage to street | Cleared | 10/28/2024 | LEE GUILBEAUX |
| Public Works-Highway Ded. | Cleared | 10/28/2024 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 10/30/2024 | LEE GUILBEAUX |
| Sewer availability | Cleared | 10/30/2024 | LEE GUILBEAUX |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Grigoryan,, Souren; Lic. No.: C93320 | 6506 TEESDALE AVE NORTH HOLLYWOOD, CA 91606 |
Inspector Information
| GAREN HAYRAPETYAN, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
| ROBERTO PALACIOS-LOPEZ, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 12/12/2024 | Not Ready for Inspection | MISAEL ESPARZA |
| PLUMBING-Rough | 12/12/2024 | Partial Approval | MISAEL ESPARZA |
| Excavation/Setback/Form/Re-Bar | 12/19/2024 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Footing/Foundation/Slab | 12/27/2024 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Excavation/Setback/Form/Re-Bar | 1/17/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Excavation/Setback/Form/Re-Bar | 1/27/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Footing/Foundation/Slab | 1/27/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| PLUMBING-Rough | 1/27/2025 | Partial Approval | ROBERTO PALACIOS-LOPEZ |
| Floor/Roof Diaphrgm/Shear Wall | 1/30/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| ELECTRICAL-Rough | 1/31/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| HVAC-Rough | 1/31/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| PLUMBING-Rough | 1/31/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| BUILDING-Rough-Frame | 2/10/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| ELECTRICAL-Rough | 2/10/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Floor/Roof Diaphrgm/Shear Wall | 2/10/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| HVAC-Rough | 2/10/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| PLUMBING-Rough | 2/10/2025 | Conditional Approval | ROBERTO PALACIOS-LOPEZ |
| Underground Mechanical | 2/10/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Interior/Exterior Lathing | 2/20/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Insulation | 3/6/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| BUILDING-Rough-Frame | 3/12/2025 | Partial Approval | ROBERTO PALACIOS-LOPEZ |
| Drywall Nailing | 3/12/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Green Building Rough | 3/12/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Insulation | 3/12/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| PLUMBING-Rough | 3/12/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Verify Sprinkler Sign Off | 3/12/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| BUILDING-Rough-Frame | 5/14/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Final | 5/14/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Green Building Final | 5/14/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| SGSOV-Seismic Gas S/O Valve | 5/14/2025 | SGSOV Not Required | ROBERTO PALACIOS-LOPEZ |
| Service/Power Release | 5/14/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Smoke Detectors | 5/14/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Final | 5/20/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Green Building Final | 5/20/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Service/Power Release | 5/20/2025 | Not Ready for Inspection | ROBERTO PALACIOS-LOPEZ |
| Final | 5/22/2025 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
| Service/Power Release | 5/22/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Special/Order Compliance | 5/22/2025 | Approved | ROBERTO PALACIOS-LOPEZ |
| Final | 5/30/2025 | OK to Issue CofO | ROBERTO PALACIOS-LOPEZ |