19529 W STRATHERN ST 91335
Certificate Information: 19529 W STRATHERN ST 91335
- Application / Permit
- 24010-20000-03963
- Plan Check / Job No.
- B24VN17042
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- New irregular shaped one story 41' 7" x 35' 9" ADU per GC 66323(a)(4). NFPA 13D sprinkler required. All work done per engineer.
- Permit Issued
- Issued on 2/12/2025
- Issuing Office
- Current Status
- CofO Issued on 2/26/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/19/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 9/26/2024 | NAREG ATARIAN |
| Corrections Issued | 9/29/2024 | NAREG ATARIAN |
| Quality Review Completed | 10/8/2024 | RARES BODEA |
| Building Plans Picked Up | 10/9/2024 | APPLICANT |
| Applicant returned to address corrections | 11/20/2024 | NAREG ATARIAN |
| Plan Check Approved | 2/12/2025 | NAREG ATARIAN |
| Issued | 2/12/2025 | APPLICANT |
| CofO in Progress | 1/27/2026 | ARUTYUN MADATYAN |
| Permit Finaled | 2/26/2026 | JOHN JANSON |
| CofO Issued | 2/26/2026 | JOHN JANSON |
| Permit Finaled | 2/26/2026 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 10/22/2024 | RYAN CASTRO |
| Roof/Waste drainage to street | Cleared | 10/22/2024 | RYAN CASTRO |
| Eng Process Fee Ord 176,300 | Cleared | 10/24/2024 | RYAN CASTRO |
| Sewer availability | Cleared | 10/24/2024 | RYAN CASTRO |
| Hydrant and Access approval | Cleared | 2/12/2025 | FRANK GOMEZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Wang,, Hongyu; Lic. No.: C72679 | 8887 W FALMINGO RD STE 101 LAS VEGAS, NV 89147 |
Inspector Information
| ARUTYUN MADATYAN, (818) 774-4307 | Office Hours: 7:00-8:00 AM MON-FRI |
| JUAN ALVARADO, (818) 774-4307 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 4/25/2025 | Approved | ARUTYUN MADATYAN |
| Footing/Foundation/Slab | 4/25/2025 | Approved | ARUTYUN MADATYAN |
| PLUMBING-Rough | 4/25/2025 | Partial Approval | ARUTYUN MADATYAN |
| Deputy Wood Construction | 5/19/2025 | Approved | ARUTYUN MADATYAN |
| Floor/Roof Diaphrgm/Shear Wall | 5/19/2025 | Corrections Issued | ARUTYUN MADATYAN |
| ELECTRICAL-Rough | 6/6/2025 | Approved | ARUTYUN MADATYAN |
| PLUMBING-Rough | 6/6/2025 | Approved | ARUTYUN MADATYAN |
| Floor/Roof Diaphrgm/Shear Wall | 6/16/2025 | Approved | ARUTYUN MADATYAN |
| HVAC-Rough | 6/16/2025 | Approved | ARUTYUN MADATYAN |
| Shower Pan | 6/16/2025 | Not Ready for Inspection | ARUTYUN MADATYAN |
| Interior/Exterior Lathing | 6/26/2025 | Not Ready for Inspection | JUAN ALVARADO |
| Shower Pan | 6/26/2025 | Approved | JUAN ALVARADO |
| BUILDING-Rough-Frame | 7/2/2025 | Partial Approval | ROBERT GOLD |
| Green Building Rough | 7/2/2025 | Approved | ROBERT GOLD |
| Interior/Exterior Lathing | 7/2/2025 | Partial Approval | ROBERT GOLD |
| Verify Sprinkler Sign Off | 7/2/2025 | Approved | ROBERT GOLD |
| BUILDING-Rough-Frame | 7/15/2025 | No Access for Inspection | ARUTYUN MADATYAN |
| BUILDING-Rough-Frame | 7/18/2025 | Approved | ARUTYUN MADATYAN |
| Insulation | 7/18/2025 | Approved | ARUTYUN MADATYAN |
| Drywall Nailing | 7/23/2025 | Approved | ARUTYUN MADATYAN |
| Interior/Exterior Lathing | 7/23/2025 | Approved | ARUTYUN MADATYAN |
| Gas Test | 8/14/2025 | Not Ready for Inspection | ARUTYUN MADATYAN |
| Underground Mechanical | 8/14/2025 | Approved | ARUTYUN MADATYAN |
| Underground Mechanical | 9/19/2025 | No Access for Inspection | KRISTEN CAUSEY |
| ELECTRICAL-Final | 12/4/2025 | Not Ready for Inspection | ARUTYUN MADATYAN |
| Final | 12/4/2025 | Corrections Issued | ARUTYUN MADATYAN |
| HVAC-Final | 12/4/2025 | Not Ready for Inspection | ARUTYUN MADATYAN |
| ELECTRICAL-Final | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| Final | 1/20/2026 | Not Ready for Inspection | ARUTYUN MADATYAN |
| Gas Test | 1/20/2026 | No Access for Inspection | ARUTYUN MADATYAN |
| Green Building Final | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| HVAC-Final | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| PLUMBING-Final | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| SGSOV-Seismic Gas S/O Valve | 1/20/2026 | SGSOV No Gas | ARUTYUN MADATYAN |
| Service/Power Release | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| Smoke Detectors | 1/20/2026 | Approved | ARUTYUN MADATYAN |
| ELECTRICAL-Final | 1/26/2026 | Approved | ARUTYUN MADATYAN |
| Final | 1/26/2026 | OK to Issue CofO | ARUTYUN MADATYAN |
| Gas Test | 1/26/2026 | Approved | ARUTYUN MADATYAN |
| HVAC-Final | 1/26/2026 | Approved | ARUTYUN MADATYAN |
| PLUMBING-Final | 1/26/2026 | Approved | ARUTYUN MADATYAN |