13103 W DESMOND ST 91331
Certificate Information: 13103 W DESMOND ST 91331
- Application / Permit
- 24010-20000-03377
- Plan Check / Job No.
- B24VN12770
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- (N) 34' X 25' DETACHED ONE STORY ACCESSORY DWELLING UNIT AS PER CA Govt. Code 65852.2(e)(1)(B) and applicable part ofLAMC 12.22 A.33 (c)-(d), (g), ALL WORK PER WFPP
- Permit Issued
- Issued on 9/10/2024
- Issuing Office
- Valley
- Current Status
- CofO Issued on 1/28/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/12/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 8/15/2024 | RARES BODEA |
| Corrections Issued | 8/19/2024 | RARES BODEA |
| Quality Review Completed | 8/29/2024 | STEVEN KIM |
| Building Plans Picked Up | 8/30/2024 | APPLICANT |
| Plan Check Approved | 9/10/2024 | RARES BODEA |
| Issued | 9/10/2024 | APPLICANT |
| CofO in Progress | 1/10/2025 | MICHEL ABAJAN |
| Permit Finaled | 1/28/2025 | RUBEN SALAS |
| CofO Issued | 1/28/2025 | RUBEN SALAS |
| Permit Finaled | 1/28/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Miscellaneous | Cleared | 8/30/2024 | JAZMIN ROQUE |
| Address approval | Cleared | 9/3/2024 | RYAN CASTRO |
| Eng Process Fee Ord 176,300 | Cleared | 9/3/2024 | RYAN CASTRO |
| Roof/Waste drainage to street | Cleared | 9/3/2024 | RYAN CASTRO |
| Sewer availability | Cleared | 9/3/2024 | RYAN CASTRO |
Contact Information
| Contractor | G Guttierrez Constrcution Inc; Lic. No.: 1110518-B | 13614 FELLOWS AVENUE SYLMAR, CA 91342 |
Inspector Information
| MICHEL ABAJAN, (818) 374-9932 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 10/11/2024 | Partial Approval | MICHEL ABAJAN |
| Pre-Inspection | 10/11/2024 | Partial Inspection | MICHEL ABAJAN |
| Excavation/Setback/Form/Re-Bar | 10/18/2024 | Approved | MICHEL ABAJAN |
| PLUMBING-Rough | 10/18/2024 | Partial Inspection | MICHEL ABAJAN |
| Floor/Roof Diaphrgm/Shear Wall | 11/4/2024 | Partial Approval | MICHEL ABAJAN |
| Green Building Rough | 11/4/2024 | Partial Inspection | MICHEL ABAJAN |
| MERV13>=Rough | 11/4/2024 | Partial Inspection | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 11/12/2024 | Approved | MICHEL ABAJAN |
| ELECTRICAL-Rough | 11/12/2024 | Approved | MICHEL ABAJAN |
| Green Building Rough | 11/12/2024 | Approved | MICHEL ABAJAN |
| HVAC-Rough | 11/12/2024 | Approved | MICHEL ABAJAN |
| Interior/Exterior Lathing | 11/12/2024 | Approved | MICHEL ABAJAN |
| MERV13>=Rough | 11/12/2024 | Approved | MICHEL ABAJAN |
| PLUMBING-Rough | 11/12/2024 | Approved | MICHEL ABAJAN |
| Insulation | 11/18/2024 | Conditional Approval | MICHEL ABAJAN |
| Drywall Nailing | 11/26/2024 | Corrections Issued | LOUIS ESCOTO |
| Shower Pan | 11/26/2024 | Approved | LOUIS ESCOTO |
| Drywall Nailing | 12/3/2024 | Approved | LOUIS ESCOTO |
| Insulation | 12/3/2024 | Approved | LOUIS ESCOTO |
| ELECTRICAL-Final | 1/8/2025 | Approved | MICHEL ABAJAN |
| Final | 1/8/2025 | Corrections Issued | MICHEL ABAJAN |
| Footing/Foundation/Slab | 1/8/2025 | Approved | MICHEL ABAJAN |
| Green Building Final | 1/8/2025 | Approved | MICHEL ABAJAN |
| HVAC-Final | 1/8/2025 | Approved | MICHEL ABAJAN |
| MERV13>=Final | 1/8/2025 | Approved | MICHEL ABAJAN |
| PLUMBING-Final | 1/8/2025 | Approved | MICHEL ABAJAN |
| SGSOV-Seismic Gas S/O Valve | 1/8/2025 | SGSOV Not Required | MICHEL ABAJAN |
| Service/Power Release | 1/8/2025 | Not Ready for Inspection | MICHEL ABAJAN |
| Smoke Detectors | 1/8/2025 | Approved | MICHEL ABAJAN |
| Final | 1/10/2025 | OK to Issue CofO | MICHEL ABAJAN |