16749 W ADDISON ST 91436
Certificate Information: 16749 W ADDISON ST 91436
- Application / Permit
- 24010-20000-02832
- Plan Check / Job No.
- B24VN09591
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 69'6" X 42'6" TWO STORY SFD WITH ATTACHED TWO CAR GARAGE, NFPA-13D FIRE SPRINKLERS REQUIRED THROUGHOUT , ALL WORK PER ENGINEERING
- Permit Issued
- Issued on 10/17/2024
- Issuing Office
- Valley
- Current Status
- CofO Issued on 5/11/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/8/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 7/11/2024 | RARES BODEA |
| Corrections Issued | 7/16/2024 | RARES BODEA |
| Quality Review Completed | 7/18/2024 | STEVEN KIM |
| Building Plans Picked Up | 7/26/2024 | APPLICANT |
| Applicant returned to address corrections | 8/21/2024 | RARES BODEA |
| Applicant returned to address corrections | 10/4/2024 | RARES BODEA |
| Plan Check Approved | 10/17/2024 | RARES BODEA |
| Issued | 10/17/2024 | APPLICANT |
| CofO in Progress | 4/7/2026 | THOMAS FINNILA |
| Permit Finaled | 5/11/2026 | JOHN JANSON |
| CofO Issued | 5/11/2026 | JOHN JANSON |
| Permit Finaled | 5/11/2026 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 8/15/2024 | CARLOS RAMIREZ |
| Eng Process Fee Ord 176,300 | Cleared | 8/16/2024 | CARLOS RAMIREZ |
| Sewer availability | Cleared | 8/16/2024 | CARLOS RAMIREZ |
| Low Impact Development (LID) | Cleared | 8/28/2024 | MARCO SANCHEZ |
| Roof/Waste drainage to street | Cleared | 9/10/2024 | LEE GUILBEAUX |
| Trees in Parkway | Cleared | 9/10/2024 | ADALBERTO VERA |
| Permit | Cleared | 10/7/2024 | CARLOS RAMIREZ |
| Hydrant and Access approval | Cleared | 10/16/2024 | PATRICK PEREZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 3625 BEVERLY RIDGE DRIVE SHERMAN OAKS, CA 91423 |
Inspector Information
| THOMAS FINNILA, (818) 774-4324 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 10/22/2024 | Not Ready for Inspection | THOMAS FINNILA |
| Underground Mechanical | 10/22/2024 | Partial Approval | THOMAS FINNILA |
| Excavation/Setback/Form/Re-Bar | 10/30/2024 | Conditional Approval | THOMAS FINNILA |
| Deputy Reinf. Concrete | 11/1/2024 | Conditional Approval | THOMAS FINNILA |
| Deputy Wood Construction | 11/18/2024 | Conditional Approval | THOMAS FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 11/19/2024 | Partial Approval | SCOTT SOBEL |
| Floor/Roof Diaphrgm/Shear Wall | 12/11/2024 | Partial Approval | THOMAS FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 12/19/2024 | Partial Approval | THOMAS FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 1/24/2025 | Partial Approval | JOHN COLEMAN |
| HVAC-Rough | 2/6/2025 | Not Ready for Inspection | GEVORK IPCHYAN |
| PLUMBING-Rough | 2/11/2025 | Approved | THOMAS FINNILA |
| ELECTRICAL-Rough | 2/19/2025 | Conditional Approval | THOMAS FINNILA |
| HVAC-Rough | 2/19/2025 | Approved | THOMAS FINNILA |
| BUILDING-Rough-Frame | 2/24/2025 | Conditional Approval | THOMAS FINNILA |
| ELECTRICAL-Rough | 2/24/2025 | Approved | THOMAS FINNILA |
| Green Building Rough | 2/24/2025 | Approved | THOMAS FINNILA |
| Verify Sprinkler Sign Off | 2/24/2025 | Approved | THOMAS FINNILA |
| Interior/Exterior Lathing | 2/25/2025 | Partial Approval | THOMAS FINNILA |
| BUILDING-Rough-Frame | 3/3/2025 | Approved | JOHN COLEMAN |
| Insulation | 3/3/2025 | Approved | JOHN COLEMAN |
| Drywall Nailing | 3/10/2025 | Approved | JUAN ALVARADO |
| Interior/Exterior Lathing | 3/17/2025 | Partial Approval | JOHN COLEMAN |
| Shower Pan | 3/17/2025 | Approved | JOHN COLEMAN |
| Underground Mechanical | 5/15/2025 | Partial Approval | THOMAS FINNILA |
| Underground Mechanical | 5/21/2025 | Approved | ROBERT GOLD |
| ELECTRICAL-Final | 11/12/2025 | Corrections Issued | THOMAS FINNILA |
| HVAC-Final | 11/12/2025 | Corrections Issued | THOMAS FINNILA |
| ELECTRICAL-Final | 11/21/2025 | Approved | THOMAS FINNILA |
| HVAC-Final | 11/21/2025 | Approved | THOMAS FINNILA |
| PLUMBING-Final | 11/21/2025 | Approved | THOMAS FINNILA |
| Final | 4/6/2026 | OK to Issue CofO | THOMAS FINNILA |
| Footing/Foundation/Slab | 4/6/2026 | Approved | THOMAS FINNILA |
| Green Building Final | 4/6/2026 | Approved | THOMAS FINNILA |
| SGSOV-Seismic Gas S/O Valve | 4/6/2026 | SGSOV Not Required | THOMAS FINNILA |
| Service/Power Release | 4/6/2026 | Approved | THOMAS FINNILA |
| Smoke Detectors | 4/6/2026 | Approved | THOMAS FINNILA |