20520 W SHERMAN WAY 91306

Certificate Information: 20520 W SHERMAN WAY 91306

Application / Permit
24010-20000-00356
Plan Check / Job No.
B24VN01156
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 30'2" X 49' DETACHED, FULLY ELECTRIC, IRREGULARLY SHAPED ACCESSORY DWELLING UNIT (1122 SF) PER LAMC 12.22.A.33(c) AND (d). WORK DONE PER ENGINEER DESIGN. NFPA-13D FIRE SPRINKLERS TO BE INSTALLED THROUGHOUT.
Permit Issued
Issued on 3/26/2024
Issuing Office
Current Status
CofO Issued on 9/6/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/29/2024 APPLICANT
Assigned to Plan Check Engineer 2/1/2024 MADISON ODELL
Corrections Issued 2/2/2024 MADISON ODELL
Applicant returned to address corrections 3/15/2024 MADISON ODELL
Plan Check Approved 3/22/2024 PINANK PATEL
Issued 3/26/2024 APPLICANT
CofO in Progress 7/16/2025 ALEXANDER HANDY
Permit Finaled 9/6/2025 MICHAEL PELHAM
CofO Issued 9/6/2025 MICHAEL PELHAM
Permit Finaled 9/6/2025 MICHAEL PELHAM

Permit Application Clearance Information

Address approval Cleared 2/2/2024 CARLOS RAMIREZ
Sewer availability Cleared 2/2/2024 CARLOS RAMIREZ
Eng Process Fee Ord 176,300 Cleared 2/6/2024 CARLOS RAMIREZ
Low Impact Development (LID) Cleared 2/6/2024 SAMUEL LINN
Roof/Waste drainage to street Cleared 2/7/2024 CARLOS RAMIREZ
ZI Cleared 3/7/2024 GEORGIA SMITH

Contact Information

Contractor Owner-Builder       ,
Engineer Sivushenka,, Mikita; Lic. No.: C87698 22814 DOLOROSA ST      WOODLAND HILLS, CA 91367

Inspector Information

ALEXANDER HANDY, (818) 774-4317 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 4/8/2024 Corrections Issued ARUTYUN MADATYAN
PLUMBING-Rough 4/8/2024 Not Ready for Inspection ARUTYUN MADATYAN
Excavation/Setback/Form/Re-Bar 4/16/2024 Partial Approval ARUTYUN MADATYAN
PLUMBING-Rough 4/16/2024 Partial Approval ARUTYUN MADATYAN
Footing/Foundation/Slab 4/30/2024 Corrections Issued ARUTYUN MADATYAN
Excavation/Setback/Form/Re-Bar 5/1/2024 Approved ARUTYUN MADATYAN
Floor/Roof Diaphrgm/Shear Wall 8/28/2024 Corrections Issued ARUTYUN MADATYAN
Floor/Roof Diaphrgm/Shear Wall 8/30/2024 Approved ARUTYUN MADATYAN
Interior/Exterior Lathing 9/20/2024 Partial Approval SCOTT SOBEL
BUILDING-Rough-Frame 10/28/2024 Conditional Approval ARUTYUN MADATYAN
ELECTRICAL-Rough 10/28/2024 Approved ARUTYUN MADATYAN
Green Building Rough 10/28/2024 Approved ARUTYUN MADATYAN
HVAC-Rough 10/28/2024 Approved ARUTYUN MADATYAN
PLUMBING-Rough 10/28/2024 Approved ARUTYUN MADATYAN
Insulation 11/1/2024 Approved ARUTYUN MADATYAN
Drywall Nailing 11/12/2024 Approved ALEXANDER HANDY
Interior/Exterior Lathing 11/12/2024 Approved ALEXANDER HANDY
Shower Pan 11/12/2024 Approved ALEXANDER HANDY
ELECTRICAL-Final 5/16/2025 Approved ALEXANDER HANDY
HVAC-Final 5/16/2025 Approved ALEXANDER HANDY
PLUMBING-Final 5/16/2025 Approved ALEXANDER HANDY
BUILDING-Rough-Frame 6/23/2025 Approved ROBERT GOLD
Final 6/23/2025 Corrections Issued ROBERT GOLD
Footing/Foundation/Slab 6/23/2025 Approved ROBERT GOLD
Green Building Final 6/23/2025 Approved ROBERT GOLD
SGSOV-Seismic Gas S/O Valve 6/23/2025 SGSOV Not Ready ROBERT GOLD
Service/Power Release 6/23/2025 Not Ready for Inspection ROBERT GOLD
Smoke Detectors 6/23/2025 Not Ready for Inspection ROBERT GOLD
Verify Sprinkler Sign Off 6/23/2025 Approved ROBERT GOLD
Final 7/14/2025 OK to Issue CofO ALEXANDER HANDY
SGSOV-Seismic Gas S/O Valve 7/14/2025 SGSOV Approved ALEXANDER HANDY
Service/Power Release 7/14/2025 Approved ALEXANDER HANDY
Smoke Detectors 7/14/2025 Approved ALEXANDER HANDY