8802 N COSTELLO AVE 91402
Certificate Information: 8802 N COSTELLO AVE 91402
- Application / Permit
- 24010-10000-05101
- Plan Check / Job No.
- B24LA35869
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW DETACHED ADU PER LAMC 12.22 A.33 (c)(d)
- Permit Issued
- Issued on 2/26/2025
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 8/19/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/12/2024 | APPLICANT |
| Assigned to Plan Check Engineer | 12/26/2024 | KHUONG TRUONG |
| Corrections Issued | 12/31/2024 | KHUONG TRUONG |
| Quality Review Completed | 1/3/2025 | KEN GILL |
| Building Plans Picked Up | 1/7/2025 | APPLICANT |
| Plan Check Approved | 2/21/2025 | KHUONG TRUONG |
| Issued | 2/26/2025 | APPLICANT |
| CofO in Progress | 7/30/2025 | VINCENT HANLEY |
| Permit Finaled | 8/19/2025 | RUBEN SALAS |
| CofO Issued | 8/19/2025 | RUBEN SALAS |
| Permit Finaled | 8/19/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 1/25/2025 | BIAINA HARITUNIAN |
| Roof/Waste drainage to street | Cleared | 1/25/2025 | BIAINA HARITUNIAN |
| Construction near power lines | Cleared | 2/13/2025 | RIDWAN HARDY |
| Eng Process Fee Ord 176,300 | Cleared | 2/19/2025 | BIAINA HARITUNIAN |
| Sewer availability | Cleared | 2/19/2025 | BIAINA HARITUNIAN |
Contact Information
| Contractor | Golden Estate Builders Inc; Lic. No.: 1113809-B | 640 S CURSON AVE APT 305 LOS ANGELES, CA 90036 |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 3625 BEVERLY RIDGE DRIVE SHERMAN OAKS, CA 91423 |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 3/18/2025 | Partial Approval | VINCENT HANLEY |
| Excavation/Setback/Form/Re-Bar | 3/27/2025 | Approved | VINCENT HANLEY |
| Footing/Foundation/Slab | 3/27/2025 | Approved | VINCENT HANLEY |
| BUILDING-Rough-Frame | 4/15/2025 | Partial Approval | MATTHEW NELSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/15/2025 | Partial Approval | MATTHEW NELSON |
| Green Building Rough | 4/15/2025 | Not Ready for Inspection | MATTHEW NELSON |
| Verify Sprinkler Sign Off | 4/15/2025 | Approved | MATTHEW NELSON |
| BUILDING-Rough-Frame | 4/25/2025 | Partial Approval | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 4/25/2025 | Partial Approval | VINCENT HANLEY |
| Green Building Rough | 4/25/2025 | Not Ready for Inspection | VINCENT HANLEY |
| PLUMBING-Rough | 4/25/2025 | Not Ready for Inspection | VINCENT HANLEY |
| Sewer | 4/25/2025 | Not Ready for Inspection | VINCENT HANLEY |
| ELECTRICAL-Rough | 5/1/2025 | Corrections Issued | VINCENT HANLEY |
| Interior/Exterior Lathing | 5/1/2025 | Corrections Issued | VINCENT HANLEY |
| PLUMBING-Rough | 5/1/2025 | Corrections Issued | VINCENT HANLEY |
| Sewer | 5/1/2025 | Partial Approval | VINCENT HANLEY |
| Special/Order Compliance | 5/1/2025 | Approved | DAVID MATSON |
| ELECTRICAL-Rough | 5/6/2025 | Approved | VINCENT HANLEY |
| HVAC-Rough | 5/6/2025 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 5/6/2025 | Partial Approval | VINCENT HANLEY |
| PLUMBING-Rough | 5/6/2025 | Approved | VINCENT HANLEY |
| Insulation | 5/9/2025 | Approved | MICHEL ABAJAN |
| Interior/Exterior Lathing | 5/9/2025 | Approved | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 5/16/2025 | Approved | LOUIS ESCOTO |
| Drywall Nailing | 5/16/2025 | Approved | LOUIS ESCOTO |
| Green Building Rough | 5/16/2025 | Approved | LOUIS ESCOTO |
| ELECTRICAL-Final | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| Final | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| Green Building Final | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| HVAC-Final | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| PLUMBING-Final | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| SGSOV-Seismic Gas S/O Valve | 7/14/2025 | SGSOV Not Ready | RYAN SALAZAR |
| Service/Power Release | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| Smoke Detectors | 7/14/2025 | Not Ready for Inspection | RYAN SALAZAR |
| ELECTRICAL-Final | 7/25/2025 | Approved | VINCENT HANLEY |
| Final | 7/25/2025 | Corrections Issued | VINCENT HANLEY |
| Green Building Final | 7/25/2025 | Approved | VINCENT HANLEY |
| HVAC-Final | 7/25/2025 | Approved | VINCENT HANLEY |
| PLUMBING-Final | 7/25/2025 | Approved | VINCENT HANLEY |
| SGSOV-Seismic Gas S/O Valve | 7/25/2025 | SGSOV Not Required | VINCENT HANLEY |
| Service/Power Release | 7/25/2025 | Approved | VINCENT HANLEY |
| Smoke Detectors | 7/25/2025 | Approved | VINCENT HANLEY |
| Final | 7/30/2025 | OK to Issue CofO | VINCENT HANLEY |