12206 W HILLSLOPE ST 91604
Certificate Information: 12206 W HILLSLOPE ST 91604
- Application / Permit
- 23047-30000-01149
- Plan Check / Job No.
- B23WL01849
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- new pool & spa per std. plan 268 & engineering details 672.
- Permit Issued
- Issued on 12/12/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 7/30/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/19/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 7/21/2023 | JOHNPAUL ISIP |
| Corrections Issued | 7/24/2023 | JOHNPAUL ISIP |
| Building Plans Picked Up | 8/2/2023 | APPLICANT |
| Plan Check Approved | 12/6/2023 | SERGIO MUNIZ |
| Issued | 12/12/2023 | APPLICANT |
| CofO in Progress | 7/14/2025 | CHRISTOPHE COCHRAN |
| Permit Finaled | 7/30/2025 | RUBEN SALAS |
| CofO Issued | 7/30/2025 | RUBEN SALAS |
| Permit Finaled | 7/30/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Construction near power lines | Cleared | 11/3/2023 | RIDWAN HARDY |
| ZI | Cleared | 11/20/2023 | NATHAN ROMINE |
| Grading Pre-Inspection | Cleared | 12/6/2023 | MANUEL TEJADA |
Contact Information
| Contractor | Intex Design And Construction Inc; Lic. No.: 981718-B | 15021 VENTURA BLVD STE 520 SHERMAN OAKS, CA 91403 |
| Engineer | Thompson,, Matthew Gregory; Lic. No.: C86051 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| CHRISTOPHE COCHRAN, (818) 374-1165 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Gunite | 3/29/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Rough-Electrical | 3/29/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Rough-Plumbing | 3/29/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Pre-Gunite | 4/3/2024 | Conditional Approval | JOHN COLEMAN |
| Rough-Electrical | 4/3/2024 | Approved | JOHN COLEMAN |
| Rough-Plumbing | 4/3/2024 | Approved | JOHN COLEMAN |
| Deputy Shotcrete | 4/5/2024 | Conditional Approval | JUAN VALENZUELA |
| Enclosure/Fence | 10/23/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| Grounding or Bonding | 10/23/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Enclosure/Fence | 11/20/2024 | Approved | CHRISTOPHE COCHRAN |
| Excavation/Setback/Form/Re-Bar | 5/19/2025 | Approved | CHRISTOPHE COCHRAN |
| Final | 5/19/2025 | Corrections Issued | CHRISTOPHE COCHRAN |
| Pre-Gunite | 5/19/2025 | Approved | CHRISTOPHE COCHRAN |
| SGSOV-Seismic Gas S/O Valve | 5/19/2025 | SGSOV Approved | CHRISTOPHE COCHRAN |
| Equipment Noise Level | 5/22/2025 | Approved | FELIPE PENICHE |
| Final | 7/11/2025 | OK to Issue CofO | CHRISTOPHE COCHRAN |