5831 N SHIRLEY AVE 91356
Certificate Information: 5831 N SHIRLEY AVE 91356
- Application / Permit
- 23047-20000-00569
- Plan Check / Job No.
- B23VN04164
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW IRREGULAR SHAPED POOL/SPA 45'-6" X 28'-0" POOL AND 6'-0" X 9'-0" SPA PER LA CITY STD PLAN No. 268 AND ENG DETAILS.
- Permit Issued
- Issued on 4/3/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 8/1/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/3/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 4/3/2023 | LUISANGEL VALENZUELA |
| Issued | 4/3/2023 | APPLICANT |
| CofO in Progress | 6/21/2024 | JON MCHUGH |
| CofO in Progress | 7/1/2024 | JON MCHUGH |
| Permit Finaled | 8/1/2024 | JOHN JANSON |
| CofO Issued | 8/1/2024 | JOHN JANSON |
| Permit Finaled | 8/1/2024 | JOHN JANSON |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Los Angeles Pool Builders Inc; Lic. No.: 857866-C53 | 9018 BALBOA BLVD SUITE 353 NORTHRIDGE, CA 91325 |
| Engineer | Thompson,, Matthew Gregory; Lic. No.: C86051 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Gunite | 4/27/2023 | Approved | JON MCHUGH |
| Deputy Shotcrete | 5/1/2023 | Conditional Approval | JON MCHUGH |
| Gas Piping or Gas Test | 6/22/2023 | Corrections Issued | JON MCHUGH |
| Grounding or Bonding | 10/20/2023 | Corrections Issued | JON MCHUGH |
| Grounding or Bonding | 12/5/2023 | Corrections Issued | JON MCHUGH |
| Enclosure/Fence | 4/19/2024 | Corrections Issued | JON MCHUGH |
| Enclosure/Fence | 4/23/2024 | Corrections Issued | JON MCHUGH |
| Special/Order Compliance | 4/23/2024 | Not Ready for Inspection | JON MCHUGH |
| Enclosure/Fence | 4/25/2024 | Approved | JON MCHUGH |
| Equipment Noise Level | 5/16/2024 | Approved | FELIPE PENICHE |
| Excavation/Setback/Form/Re-Bar | 5/30/2024 | Approved | JON MCHUGH |
| Final | 5/30/2024 | Corrections Issued | JON MCHUGH |
| SGSOV-Seismic Gas S/O Valve | 5/30/2024 | SGSOV Approved | JON MCHUGH |
| Final | 6/4/2024 | Corrections Issued | JON MCHUGH |
| ELECTRICAL-Final | 6/21/2024 | Approved | JON MCHUGH |
| Final | 6/21/2024 | OK to Issue CofO | JON MCHUGH |
| Final | 7/1/2024 | OK to Issue CofO | JON MCHUGH |