9078 N HELEN AVE 91352
Certificate Information: 9078 N HELEN AVE 91352
- Application / Permit
- 23030-10000-03072
- Plan Check / Job No.
- G23LA00072
- Group
- Building
- Type
- Grading
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (70) Grading - Hillside
- Work Description
- INSTALL TIER I OWTS FOR 4 BEDROOM RESIDENCE AND 2 BEDROOM ADU: TANK CAPACITY = 2,000 GAL, LEACH LINE = (2) 70'x 3'W x 5'DEEP W/ 3' ROCK BELOW PIPE
- Permit Issued
- Issued on 8/31/2023
- Issuing Office
- Current Status
- Permit Finaled on 5/13/2025
Permit Application Status History
| Submitted | 5/11/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 5/23/2023 | DAN RYAN EVANGELISTA |
| Corrections Issued | 5/23/2023 | DAN RYAN EVANGELISTA |
| Plan Check Approved | 8/31/2023 | DAN RYAN EVANGELISTA |
| Issued | 8/31/2023 | APPLICANT |
| Permit Finaled | 5/13/2025 | CHARLES POWELL |
Permit Application Clearance Information
| Specific Plan | Cleared | 8/29/2023 | JOSHUA ORDONEZ |
| Excavation more than 5-ft deep | Cleared | 8/31/2023 | CALOSHA APPROVED |
| Grading Pre-Inspection | Cleared | 8/31/2023 | ROBERT PINA |
Contact Information
| Contractor | Acosta & Sons Sewer Contractor; Lic. No.: 273035-A | 1434 E MOUNTAIN ST GLENDALE, CA 91207 |
Inspector Information
| BRIAN MILLER, (818) 374-4359 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation | 5/15/2024 | Not Ready for Inspection | LANNY MERRICK |
| Initial Grading | 5/15/2024 | Approved | LANNY MERRICK |
| Bottom/Toe | 5/24/2024 | Partial Approval | CHARLES POWELL |
| Excavation | 5/24/2024 | Partial Approval | CHARLES POWELL |
| Approved Compaction Report | 6/10/2024 | Not Ready for Inspection | MANUEL TEJADA |
| Initial Grading | 6/10/2024 | Not Ready for Inspection | MANUEL TEJADA |
| Initial Grading | 6/12/2024 | Partial Inspection | MANUEL TEJADA |
| Fill/Backfill | 6/18/2024 | Not Ready for Inspection | CHARLES POWELL |
| Initial Grading | 6/18/2024 | Partial Approval | CHARLES POWELL |
| Bottom/Toe | 1/29/2025 | Not Ready for Inspection | CHARLES POWELL |
| Excavation | 1/29/2025 | Corrections Issued | CHARLES POWELL |
| Excavation | 1/31/2025 | Partial Approval | CHARLES POWELL |
| Fill/Backfill | 2/19/2025 | Approved | MANUEL TEJADA |
| Approved Compaction Report | 4/11/2025 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Bottom/Toe | 5/13/2025 | Approved | CHARLES POWELL |
| Final | 5/13/2025 | Permit Finaled | CHARLES POWELL |
| Rough | 5/13/2025 | Approved | CHARLES POWELL |