11556 N MANCHESTER WAY 91326
Certificate Information: 11556 N MANCHESTER WAY 91326
- Application / Permit
- 23020-20000-01642
- Plan Check / Job No.
- B23VN11452
- Group
- Building
- Type
- Nonbldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Retaining Wall
- Work Description
- (N) 6' HIGH BY 15' LONG RETAINING WALL.
- Permit Issued
- Issued on 10/23/2023
- Issuing Office
- Current Status
- Permit Finaled on 12/15/2023
Permit Application Status History
| Submitted | 8/24/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 8/31/2023 | JESSE ARELLANO |
| Corrections Issued | 9/1/2023 | JESSE ARELLANO |
| Building Plans Picked Up | 9/6/2023 | APPLICANT |
| Issued | 10/23/2023 | APPLICANT |
| Permit Finaled | 12/14/2023 | BRIAN MILLER |
Permit Application Clearance Information
| "T" removal | Cleared | 9/13/2023 | ASHLEY RODARTE |
| Specific Plan | Cleared | 9/13/2023 | ASHLEY RODARTE |
| ZA Case | Cleared | 9/13/2023 | ASHLEY RODARTE |
| ZA Case | Cleared | 9/13/2023 | ASHLEY RODARTE |
Contact Information
| Contractor | Keystone Remodeling Inc; Lic. No.: 1065368-B | 22120 CLARENDON ST 205 WOODLAND HILLS, CA 91367 |
| Engineer | Mcpherson,, Ryan; Lic. No.: C82088 | 6169 SUNNY CIRCLE MIRA LOMA, CA 91752 |
Inspector Information
| ALEXANDER HELFER, (818) 374-4354 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 11/16/2023 | Approved | ALEXANDER HELFER |
| Masonry Wall/Backfill | 12/4/2023 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| Masonry Wall/Backfill | 12/5/2023 | Partial Approval | BRIAN MILLER |
| Reinforced Masonry Frame | 12/12/2023 | Partial Approval | BRIAN MILLER |
| Final | 12/14/2023 | Permit Finaled | BRIAN MILLER |