16033-16035 W JERSEY ST 91344

Certificate Information: 16033-16035 W JERSEY ST 91344

Application / Permit
23016-20000-45152
Plan Check / Job No.
B23VN17727
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
CONVERT (E) 18'1" X 20'4" ATTACHED GARAGE TO (N) JUNIOR ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A) AND 65852.22. WORK DONE PER WFPP AND ENGINEER DETAIL.
Permit Issued
Issued on 1/8/2024
Issuing Office
Current Status
CofO Issued on 3/31/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/26/2023 APPLICANT
Assigned to Plan Check Engineer 12/29/2023 KAMYAR EMAMI
Building Plans Picked Up 1/3/2024 APPLICANT
Issued 1/8/2024 APPLICANT
CofO in Progress 3/12/2026 CHRISTOPHER ROJAS
CofO Issued 3/31/2026 RUBEN SALAS
Permit Finaled 3/31/2026 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 1/3/2024 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 1/3/2024 LEE GUILBEAUX
Sewer availability Cleared 1/3/2024 LEE GUILBEAUX
Hold Cleared 7/8/2025 CARMEN MERAZ

Contact Information

Contractor Owner-Builder       ,
Engineer Khatchadourian,, Vicken; Lic. No.: S3141 1221 N CEDAR ST      GLENDALE, CA 92107

Inspector Information

CHRISTOPHER ROJAS, (818) 374-1160 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 7/11/2025 Partial Inspection KEVIN BERBERYAN
Deputy Drilled-In Anchors 8/4/2025 Conditional Approval JUAN VALENZUELA
Excavation/Setback/Form/Re-Bar 8/6/2025 Corrections Issued CHRISTOPHER ROJAS
PLUMBING-Rough 8/6/2025 Corrections Issued CHRISTOPHER ROJAS
Excavation/Setback/Form/Re-Bar 8/8/2025 Approved CHRISTOPHER ROJAS
PLUMBING-Rough 8/8/2025 Not Ready for Inspection CHRISTOPHER ROJAS
PLUMBING-Rough 8/13/2025 Partial Approval CHRISTOPHER ROJAS
Floor/Roof Diaphrgm/Shear Wall 8/28/2025 Partial Approval CHRISTOPHER ROJAS
Sewer 8/28/2025 Corrections Issued CHRISTOPHER ROJAS
BUILDING-Rough-Frame 9/9/2025 Corrections Issued CHRISTOPHER ROJAS
ELECTRICAL-Rough 9/9/2025 Not Ready for Inspection CHRISTOPHER ROJAS
PLUMBING-Rough 9/9/2025 Not Ready for Inspection CHRISTOPHER ROJAS
Sewer 9/9/2025 Approved CHRISTOPHER ROJAS
PLUMBING-Final 9/16/2025 Approved CHRISTOPHER ROJAS
Wood Frame 9/16/2025 Not Ready for Inspection CHRISTOPHER ROJAS
ELECTRICAL-Rough 9/19/2025 Not Ready for Inspection CHRISTOPHER ROJAS
HVAC-Rough 9/19/2025 Conditional Approval CHRISTOPHER ROJAS
BUILDING-Rough-Frame 9/29/2025 Approved CHRISTOPHER ROJAS
Green Building Rough 9/29/2025 Approved CHRISTOPHER ROJAS
Interior/Exterior Lathing 9/29/2025 Approved CHRISTOPHER ROJAS
MERV13>=Rough 9/29/2025 Approved CHRISTOPHER ROJAS
Drywall Nailing 10/7/2025 Approved CHRISTOPHER ROJAS
ELECTRICAL-Final 12/17/2025 Corrections Issued CHRISTOPHER ROJAS
Final 12/17/2025 Not Ready for Inspection CHRISTOPHER ROJAS
Green Building Final 12/17/2025 Corrections Issued CHRISTOPHER ROJAS
HVAC-Final 12/17/2025 Corrections Issued CHRISTOPHER ROJAS
MERV13>=Final 12/17/2025 Approved CHRISTOPHER ROJAS
PLUMBING-Final 12/17/2025 Corrections Issued CHRISTOPHER ROJAS
SGSOV-Seismic Gas S/O Valve 12/17/2025 SGSOV Approved CHRISTOPHER ROJAS
Smoke Detectors 12/17/2025 Approved CHRISTOPHER ROJAS
Special/Order Compliance 12/17/2025 Corrections Issued CHRISTOPHER ROJAS
ELECTRICAL-Final 1/9/2026 Corrections Issued CHRISTOPHER ROJAS
Final 1/9/2026 Corrections Issued CHRISTOPHER ROJAS
Green Building Final 1/9/2026 Corrections Issued CHRISTOPHER ROJAS
PLUMBING-Final 1/9/2026 Not Ready for Inspection CHRISTOPHER ROJAS
Final 3/10/2026 OK to Issue CofO CHRISTOPHER ROJAS
Green Building Final 3/10/2026 Approved CHRISTOPHER ROJAS
Service/Power Release 3/12/2026 Approved CHRISTOPHER ROJAS