14747-14749 W TYLER ST 91342
Certificate Information: 14747-14749 W TYLER ST 91342
- Application / Permit
- 23016-20000-40771
- Plan Check / Job No.
- B23VN15878
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERT ATTACHED GARAGE TO ATTACHED ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A).
- Permit Issued
- Issued on 3/26/2024
- Issuing Office
- Current Status
- CofO Issued on 10/29/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/17/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 11/22/2023 | MIROOSH KHACHATOORIAN |
| Corrections Issued | 11/27/2023 | MIROOSH KHACHATOORIAN |
| Applicant returned to address corrections | 3/6/2024 | MIROOSH KHACHATOORIAN |
| Applicant returned to address corrections | 3/20/2024 | MIROOSH KHACHATOORIAN |
| Plan Check Approved | 3/25/2024 | ROSENDO MEDINA |
| Issued | 3/26/2024 | APPLICANT |
| CofO in Progress | 10/23/2024 | KEVIN BERBERYAN |
| Permit Finaled | 10/29/2024 | DANIEL ORRANTE |
| CofO Issued | 10/29/2024 | DANIEL ORRANTE |
| Permit Finaled | 10/29/2024 | DANIEL ORRANTE |
Permit Application Clearance Information
| Address approval | Cleared | 11/27/2023 | LEE GUILBEAUX |
| Sewer availability | Cleared | 11/27/2023 | LEE GUILBEAUX |
| Public Works-Highway Ded. | Cleared | 11/27/2023 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 11/28/2023 | LEE GUILBEAUX |
| ZI | Cleared | 11/28/2023 | RUBEN VASQUEZ |
| Construction near power lines | Cleared | 3/5/2024 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Abedian,, Vanik; Lic. No.: S5323 | 2906 JOLLEY DR BURBANK, CA 91504 |
Inspector Information
| KEVIN BERBERYAN, (818) 374-9931 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Gas Test | 6/3/2024 | Approved | KEVIN BERBERYAN |
| Deputy Drilled-In Anchors | 6/7/2024 | Conditional Approval | DAVID MATSON |
| Excavation/Setback/Form/Re-Bar | 6/11/2024 | Approved | KEVIN BERBERYAN |
| Underground Mechanical | 6/11/2024 | Approved | KEVIN BERBERYAN |
| ELECTRICAL-Rough | 7/5/2024 | Corrections Issued | KEVIN BERBERYAN |
| HVAC-Rough | 7/5/2024 | Corrections Issued | KEVIN BERBERYAN |
| PLUMBING-Rough | 7/5/2024 | Approved | KEVIN BERBERYAN |
| Deputy Drilled-In Anchors | 7/10/2024 | Conditional Approval | ROBERT GOLD |
| BUILDING-Rough-Frame | 7/11/2024 | Corrections Issued | JENNIFER RABUCHIN |
| ELECTRICAL-Rough | 7/11/2024 | Corrections Issued | JENNIFER RABUCHIN |
| Green Building Rough | 7/11/2024 | Approved | JENNIFER RABUCHIN |
| HVAC-Rough | 7/11/2024 | Corrections Issued | JENNIFER RABUCHIN |
| ELECTRICAL-Rough | 7/31/2024 | Approved | KEVIN BERBERYAN |
| HVAC-Rough | 7/31/2024 | Approved | KEVIN BERBERYAN |
| Insulation | 7/31/2024 | Corrections Issued | KEVIN BERBERYAN |
| Insulation | 8/5/2024 | Approved | JACK KARGODORIAN |
| Drywall Nailing | 8/16/2024 | Approved | KEVIN BERBERYAN |
| BUILDING-Rough-Frame | 10/2/2024 | Approved | KEVIN BERBERYAN |
| Final | 10/2/2024 | Corrections Issued | KEVIN BERBERYAN |
| Green Building Final | 10/2/2024 | Not Ready for Inspection | KEVIN BERBERYAN |
| SGSOV-Seismic Gas S/O Valve | 10/2/2024 | SGSOV Approved | KEVIN BERBERYAN |
| Smoke Detectors | 10/2/2024 | Approved | KEVIN BERBERYAN |
| Final | 10/9/2024 | OK to Issue CofO | KEVIN BERBERYAN |
| Green Building Final | 10/9/2024 | Approved | KEVIN BERBERYAN |