13953 W GARBER ST 91331

Certificate Information: 13953 W GARBER ST 91331

Application / Permit
23016-20000-31509
Plan Check / Job No.
B23VN12517
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT (E) DETACHED GARAGE TO ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A)
Permit Issued
Issued on 10/4/2023
Issuing Office
Current Status
CofO Issued on 5/1/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/14/2023 APPLICANT
Assigned to Plan Check Engineer 9/18/2023 JESSE ARELLANO
Corrections Issued 9/19/2023 JESSE ARELLANO
Building Plans Picked Up 9/20/2023 APPLICANT
Plan Check Approved 10/4/2023 OMAR GARNICA
Issued 10/4/2023 APPLICANT
CofO in Progress 4/13/2024 GREGG CUMMINGS
Permit Finaled 5/1/2024 RUBEN SALAS
CofO Issued 5/1/2024 RUBEN SALAS
Permit Finaled 5/1/2024 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 9/21/2023 RYAN KIM
Sewer availability Cleared 9/21/2023 RYAN KIM
Eng Process Fee Ord 176,300 Cleared 9/25/2023 RYAN KIM

Contact Information

Contractor Owner-Builder       ,
Engineer Khatchadourian,, Vicken; Lic. No.: S3141 1221 N CEDAR ST      GLENDALE, CA 92107

Inspector Information

OGANES TARAKHCHYAN, (818) 374-1162 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Insulation 10/25/2023 Not Ready for Inspection GREGG CUMMINGS
Interior/Exterior Lathing 10/25/2023 Not Ready for Inspection GREGG CUMMINGS
Footing/Foundation/Slab 12/22/2023 Approved GREGG CUMMINGS
PLUMBING-Rough 12/22/2023 Corrections Issued GREGG CUMMINGS
PLUMBING-Rough 12/27/2023 Not Ready for Inspection GREGG CUMMINGS
Floor/Roof Diaphrgm/Shear Wall 1/3/2024 Partial Approval MISAEL ESPARZA
PLUMBING-Rough 1/3/2024 Approved MISAEL ESPARZA
Interior/Exterior Lathing 1/10/2024 Not Ready for Inspection GREGG CUMMINGS
ELECTRICAL-Rough 1/12/2024 Approved GREGG CUMMINGS
HVAC-Rough 1/12/2024 Approved GREGG CUMMINGS
BUILDING-Rough-Frame 1/16/2024 Approved CHRISTOPHER ROJAS
Deputy Drilled-In Anchors 1/16/2024 Conditional Approval DAVID MATSON
Green Building Rough 1/16/2024 Approved CHRISTOPHER ROJAS
HVAC-Rough 1/16/2024 Approved CHRISTOPHER ROJAS
Interior/Exterior Lathing 1/16/2024 Partial Approval CHRISTOPHER ROJAS
Insulation 1/31/2024 Approved GREGG CUMMINGS
Drywall Nailing 2/7/2024 Approved GREGG CUMMINGS
Shower Pan 2/7/2024 Approved GREGG CUMMINGS
Interior/Exterior Lathing 2/9/2024 Partial Approval GREGG CUMMINGS
Final 4/1/2024 Corrections Issued JAVIER RAMOS JR
Green Building Final 4/1/2024 Approved JAVIER RAMOS JR
SGSOV-Seismic Gas S/O Valve 4/1/2024 SGSOV Not Ready JAVIER RAMOS JR
Smoke Detectors 4/1/2024 Approved JAVIER RAMOS JR
Final 4/4/2024 Corrections Issued GREGG CUMMINGS
SGSOV-Seismic Gas S/O Valve 4/4/2024 SGSOV Approved GREGG CUMMINGS
Sewer 4/4/2024 Approved GREGG CUMMINGS
Underground Mechanical 4/4/2024 Approved GREGG CUMMINGS
ELECTRICAL-Final 4/12/2024 Approved GREGG CUMMINGS
Final 4/12/2024 OK to Issue CofO GREGG CUMMINGS
HVAC-Final 4/12/2024 Approved GREGG CUMMINGS
PLUMBING-Final 4/12/2024 Approved GREGG CUMMINGS