315 N NEWLAND ST 90042

Certificate Information: 315 N NEWLAND ST 90042

Application / Permit
23016-20000-20690
Plan Check / Job No.
B23VN08301
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
REMOVE & REPLACE EXISTING FIRE DAMAGED ENTIRE PRE-FAB ROOF TRUSS FRAMING. REMOVE & REPLACE ALL WINDOWS & DOORS, AND DRYWALLS AS EXISTED PER PLAN. CONSTRUCTION/REPAIR PER ENGR DESIGN. SEE COMMENTS.
Permit Issued
Issued on 10/25/2023
Issuing Office
Valley
Current Status
Permit Finaled on 2/9/2024

Permit Application Status History

Submitted 6/22/2023 APPLICANT
Assigned to Plan Check Engineer 6/26/2023 HAYATO TSUCHIYA
Corrections Issued 6/26/2023 HAYATO TSUCHIYA
Building Plans Picked Up 6/28/2023 APPLICANT
Applicant returned to address corrections 10/24/2023 HAYATO TSUCHIYA
Issued 10/25/2023 APPLICANT
Permit Finaled 2/8/2024 ROY SPAULDING

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 6/29/2023 TREVOR QUAN
Grading Pre-Inspection Cleared 10/4/2023 SERGIO VALENZUELA
Eng Process Fee Ord 176,300 Cleared 10/17/2023 ALBERT TAM

Contact Information

Contractor Vicsinc.Com; Lic. No.: 1002544-B P O BOX 950931      MISSION HILLS, CA 91395
Engineer Espino,, Manuel A; Lic. No.: C55526 12109 WOODRUFF AVE      DOWNEY, CA 90241
Engineer Hernandez,, Arturo; Lic. No.: C72517 8653 SHAKESPEARE LANE      FRISCO, TX 75034

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 11/1/2023 Conditional Approval ROY SPAULDING
Footing/Foundation/Slab 11/6/2023 Approved ROY SPAULDING
Gas Test 11/6/2023 Approved ROY SPAULDING
PLUMBING-Rough 11/6/2023 Approved ROY SPAULDING
BUILDING-Rough-Frame 11/16/2023 Not Ready for Inspection ROY SPAULDING
ELECTRICAL-Rough 11/16/2023 Not Ready for Inspection ROY SPAULDING
HVAC-Rough 11/16/2023 Not Ready for Inspection ROY SPAULDING
PLUMBING-Rough 11/16/2023 Not Ready for Inspection ROY SPAULDING
Wood Frame 11/16/2023 Approved ROY SPAULDING
BUILDING-Rough-Frame 11/17/2023 Not Ready for Inspection ROY SPAULDING
ELECTRICAL-Rough 11/17/2023 Not Ready for Inspection ROY SPAULDING
HVAC-Rough 11/17/2023 Not Ready for Inspection ROY SPAULDING
PLUMBING-Rough 11/17/2023 Not Ready for Inspection ROY SPAULDING
ELECTRICAL-Rough 11/21/2023 Approved ROY SPAULDING
HVAC-Rough 11/21/2023 Approved ROY SPAULDING
Interior/Exterior Lathing 11/21/2023 Approved ROY SPAULDING
PLUMBING-Rough 11/21/2023 Approved ROY SPAULDING
Insulation 11/28/2023 Approved ROY SPAULDING
Interior/Exterior Lathing 11/28/2023 Approved ROY SPAULDING
Shower Pan 11/28/2023 Approved ROY SPAULDING
Service/Power Release 1/12/2024 Not Ready for Inspection ROY SPAULDING
Final 1/17/2024 Corrections Issued AMY COLIN
SGSOV-Seismic Gas S/O Valve 1/17/2024 SGSOV Not Ready AMY COLIN
Service/Power Release 1/17/2024 Not Ready for Inspection AMY COLIN
Smoke Detectors 1/17/2024 Approved AMY COLIN
Final 1/25/2024 Corrections Issued ROY SPAULDING
SGSOV-Seismic Gas S/O Valve 1/25/2024 SGSOV Approved ROY SPAULDING
Service/Power Release 1/25/2024 Not Ready for Inspection ROY SPAULDING
Final 2/8/2024 Permit Finaled ROY SPAULDING
Gas Test 2/8/2024 Approved ROY SPAULDING
Service/Power Release 2/8/2024 Approved ROY SPAULDING