19113-19115 W LUDLOW ST 91326
Certificate Information: 19113-19115 W LUDLOW ST 91326
- Application / Permit
- 23016-20000-02540
- Plan Check / Job No.
- B23VN01122
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERT EX 21'11"X22'4" ATT GARAGE INTO ACCESSORY DWELLING UNIT PER LAMC 12.22A.33(c) & (e). ALL WORK PER WFPP. SEE COMMENTS
- Permit Issued
- Issued on 2/28/2023
- Issuing Office
- Current Status
- CofO Issued on 12/7/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/30/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 2/3/2023 | HAYATO TSUCHIYA |
| Corrections Issued | 2/4/2023 | HAYATO TSUCHIYA |
| Building Plans Picked Up | 2/6/2023 | APPLICANT |
| Plan Check Approved | 2/28/2023 | ALEC MOUSAKHANIAN |
| Issued | 2/28/2023 | APPLICANT |
| CofO in Progress | 12/7/2023 | DAVID SCANTLIN |
| Permit Finaled | 12/7/2023 | JOHN JANSON |
| CofO Issued | 12/7/2023 | JOHN JANSON |
| Permit Finaled | 12/7/2023 | JOHN JANSON |
Permit Application Clearance Information
| Sewer availability | Cleared | 2/6/2023 | MEGAN GODINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 2/7/2023 | MEGAN GODINEZ |
| Public Works-Highway Ded. | Cleared | 2/7/2023 | MEGAN GODINEZ |
| Public Works-Open Permits | Cleared | 2/7/2023 | MEGAN GODINEZ |
| Public Works-Sewers | Cleared | 2/7/2023 | MEGAN GODINEZ |
| Address approval | Cleared | 2/24/2023 | MANUEL TEJADA |
| Grading Pre-Inspection | Cleared | 2/27/2023 | CHARLES POWELL |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JACK KARGODORIAN, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
| KRISTEN CAUSEY, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 7/21/2023 | Partial Approval | JOHN KIDWELL |
| Footing/Foundation/Slab | 7/25/2023 | Approved | DAVID SCANTLIN |
| Sewer | 7/25/2023 | Approved | DAVID SCANTLIN |
| Underground Mechanical | 7/25/2023 | Approved | DAVID SCANTLIN |
| Floor/Roof Diaphrgm/Shear Wall | 9/8/2023 | Approved | DAVID SCANTLIN |
| BUILDING-Rough-Frame | 9/19/2023 | Approved | DAVID SCANTLIN |
| ELECTRICAL-Rough | 9/19/2023 | Approved | DAVID SCANTLIN |
| Green Building Rough | 9/19/2023 | Approved | DAVID SCANTLIN |
| HVAC-Rough | 9/19/2023 | Approved | DAVID SCANTLIN |
| Interior/Exterior Lathing | 9/19/2023 | Partial Approval | DAVID SCANTLIN |
| MERV13>=Rough | 9/19/2023 | Approved | DAVID SCANTLIN |
| PLUMBING-Rough | 9/19/2023 | Approved | DAVID SCANTLIN |
| Insulation | 9/27/2023 | Approved | DAVID SCANTLIN |
| Drywall Nailing | 10/2/2023 | Approved | DAVID SCANTLIN |
| Interior/Exterior Lathing | 10/2/2023 | Approved | DAVID SCANTLIN |
| Final | 12/6/2023 | OK to Issue CofO | DAVID SCANTLIN |
| Green Building Final | 12/6/2023 | Approved | DAVID SCANTLIN |
| MERV13>=Final | 12/6/2023 | Approved | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 12/6/2023 | SGSOV Approved | DAVID SCANTLIN |
| Smoke Detectors | 12/6/2023 | Approved | DAVID SCANTLIN |