826 S WALKER AVE 90731
Certificate Information: 826 S WALKER AVE 90731
- Application / Permit
- 23016-10000-31081
- Plan Check / Job No.
- B23LA17038
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Eplan: Soft-Story seismic retrofit per LABC Chapter 93: SOFT STORY SEISMIC REINFORCEMENT AT BUILDING PARKING GARAGE USING (2) SPECIAL CANTILEVERED COLUMNS W/ GRADE BEAM.
- Permit Issued
- Issued on 1/30/2024
- Issuing Office
- Current Status
- CofC Issued on 7/2/2024
Permit Application Status History
| Submitted | 9/12/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 9/21/2023 | HANS SANTIAGO |
| Corrections Issued | 9/25/2023 | HANS SANTIAGO |
| Quality Review Completed | 10/17/2023 | CHARLES CHANG |
| Applicant returned to address corrections | 11/17/2023 | HANS SANTIAGO |
| Plan Check Approved | 12/18/2023 | ANDREW SANTIAGO |
| Issued | 1/30/2024 | APPLICANT |
| OK for CofC | 6/28/2024 | DARRYL ARNOLD |
| CofC Issued | 7/2/2024 | WINSTON DUNNING |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 1/25/2024 | RICARDO BOHORQUEZ |
Contact Information
| Contractor | Sturdy Builds Inc; Lic. No.: 1006879-B | 21300 VICTORY BLVD SUITE 635 WOODLAND HILLS, CA 91367 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 8232 GARVEY AVE 203 ROSEMEAD, CA 91770 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/18/2024 | Approved | JACOB MYERS |
| Deputy Other (see comments) | 4/30/2024 | Partial Approval | JACOB MYERS |
| Footing/Foundation/Slab | 5/1/2024 | Approved | JOEY BUCHANAN |
| Structural Steel Frame | 5/1/2024 | Approved | JOEY BUCHANAN |
| Wood Frame | 5/1/2024 | Approved | JOEY BUCHANAN |
| Interior/Exterior Lathing | 5/6/2024 | Approved | DARRYL ARNOLD |
| Final | 6/3/2024 | Not Ready for Inspection | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 6/3/2024 | SGSOV Not Ready | DARRYL ARNOLD |
| Smoke Detectors | 6/3/2024 | Corrections Issued | DARRYL ARNOLD |
| Final | 6/28/2024 | OK for CofC | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 6/28/2024 | SGSOV Approved | DARRYL ARNOLD |
| Smoke Detectors | 6/28/2024 | Approved | DARRYL ARNOLD |