3173 N GLENMANOR PL 90039

Certificate Information: 3173 N GLENMANOR PL 90039

Application / Permit
23016-10000-23693
Plan Check / Job No.
B23LA13249
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
eplan: CONVERT (E) DETACHED GARAGE INTO ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A)
Permit Issued
Issued on 12/29/2023
Issuing Office
Current Status
CofO Issued on 4/29/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/28/2023 APPLICANT
Assigned to Plan Check Engineer 8/4/2023 OMAR GARNICA
Corrections Issued 8/5/2023 OMAR GARNICA
Applicant returned to address corrections 9/7/2023 OMAR GARNICA
Plan Check Approved 12/22/2023 GURUNATH NESARAJAH
Issued 12/29/2023 APPLICANT
CofO in Progress 4/26/2024 HAMIK HARTOUNIAN
Permit Finaled 4/29/2024 DEROLD HAUFF
CofO Issued 4/29/2024 DEROLD HAUFF
Permit Finaled 4/29/2024 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 8/26/2023 CHRISTOPHER ROCHA
Sewer availability Cleared 8/26/2023 CHRISTOPHER ROCHA
Eng Process Fee Ord 176,300 Cleared 9/7/2023 CHRISTOPHER ROCHA
Construction near power lines Cleared 12/16/2023 RIDWAN HARDY

Contact Information

Contractor Legacy Builders & Remodeling Inc; Lic. No.: 1046784-B       ,
Engineer Southerland,, Richard Charles; Lic. No.: C88965 16526 BLACKHAWK ST      GRANADA HILLS, CA 91344

Inspector Information

NICHOLAS LOPEZ, (213) 202-3224 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 1/3/2024 Conditional Approval HAMIK HARTOUNIAN
Excavation/Setback/Form/Re-Bar 1/8/2024 Conditional Approval HAMIK HARTOUNIAN
ELECTRICAL-Rough 1/19/2024 Approved HAMIK HARTOUNIAN
HVAC-Rough 1/19/2024 Not Ready for Inspection HAMIK HARTOUNIAN
PLUMBING-Rough 1/19/2024 Approved HAMIK HARTOUNIAN
Deputy Wood Construction 1/23/2024 Conditional Approval HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 1/23/2024 Approved HAMIK HARTOUNIAN
BUILDING-Rough-Frame 1/25/2024 Corrections Issued LILIANA PORTILLO
Green Building Rough 1/25/2024 Not Ready for Inspection LILIANA PORTILLO
HVAC-Rough 1/25/2024 Not Ready for Inspection LILIANA PORTILLO
HVAC-Rough 1/29/2024 Approved ALIZAH MAYAGOITIA
Interior/Exterior Lathing 1/29/2024 Partial Approval ALIZAH MAYAGOITIA
BUILDING-Rough-Frame 1/31/2024 Approved HAMIK HARTOUNIAN
Green Building Rough 1/31/2024 Corrections Issued HAMIK HARTOUNIAN
BUILDING-Rough-Frame 2/7/2024 Approved ALIZAH MAYAGOITIA
Green Building Rough 2/7/2024 Approved ALIZAH MAYAGOITIA
Insulation 2/13/2024 Approved HAMIK HARTOUNIAN
Insulation 2/16/2024 Approved HAMIK HARTOUNIAN
Underground Mechanical 2/16/2024 Partial Approval HAMIK HARTOUNIAN
Drywall Nailing 2/21/2024 Approved CHARLES BOGHOSKHAN
Interior/Exterior Lathing 2/26/2024 Approved CHARLES BOGHOSKHAN
Shower Pan 2/26/2024 Approved CHARLES BOGHOSKHAN
Underground Mechanical 2/26/2024 Not Ready for Inspection CHARLES BOGHOSKHAN
Underground Mechanical 2/29/2024 Conditional Approval HAMIK HARTOUNIAN
Final 4/4/2024 Corrections Issued HAMIK HARTOUNIAN
Green Building Final 4/4/2024 Not Ready for Inspection HAMIK HARTOUNIAN
SGSOV-Seismic Gas S/O Valve 4/4/2024 SGSOV Not Ready HAMIK HARTOUNIAN
Smoke Detectors 4/4/2024 Not Ready for Inspection HAMIK HARTOUNIAN
Final 4/5/2024 Corrections Issued HAMIK HARTOUNIAN
Green Building Final 4/5/2024 Not Ready for Inspection HAMIK HARTOUNIAN
SGSOV-Seismic Gas S/O Valve 4/5/2024 SGSOV Not Ready HAMIK HARTOUNIAN
Smoke Detectors 4/5/2024 Approved HAMIK HARTOUNIAN
Final 4/9/2024 Corrections Issued HAMIK HARTOUNIAN
Green Building Final 4/9/2024 Approved HAMIK HARTOUNIAN
SGSOV-Seismic Gas S/O Valve 4/9/2024 SGSOV Not Ready HAMIK HARTOUNIAN
Smoke Detectors 4/9/2024 Approved HAMIK HARTOUNIAN
Final 4/19/2024 Corrections Issued HAMIK HARTOUNIAN
SGSOV-Seismic Gas S/O Valve 4/19/2024 SGSOV Approved HAMIK HARTOUNIAN
Final 4/26/2024 OK to Issue CofO HAMIK HARTOUNIAN