100 N ORANGE DR 100 90036

Certificate Information: 100 N ORANGE DR 100 90036

Application / Permit
23016-10000-17036
Plan Check / Job No.
B23LA09695
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(2) Duplex
Work Description
FIRE DAMAGE REPAIR TO PORTION OF (E) DUPLEX, KITCHEN REMODEL TO UNIT #104, MASTER BEDROOM/BATHROOM REMODEL TO BOTH UNITS OF (E) DUPLEX AND ADD POWDER ROOM TO UNIT #100. ALL WORK DONE PER ENGINEERING.
Permit Issued
Issued on 12/28/2023
Issuing Office
Current Status
Permit Finaled on 7/3/2025

Permit Application Status History

Submitted 5/24/2023 APPLICANT
Assigned to Plan Check Engineer 6/1/2023 GURUNATH NESARAJAH
Corrections Issued 6/1/2023 GURUNATH NESARAJAH
Plan Check Approved 9/20/2023 ALEC MOUSAKHANIAN
No Progress 12/27/2023 ALEC MOUSAKHANIAN
Plan Check Approved 12/27/2023 GURUNATH NESARAJAH
Issued 12/28/2023 APPLICANT
Permit Finaled 6/30/2025 ARTHUR NEGRETE

Permit Application Clearance Information

No Data Available.

Contact Information

Architect Darian, Radac; Lic. No.: C33451       ,
Contractor Westrock Restoration Llc; Lic. No.: 986693-B       ,
Contractor Westrock Restoration; Lic. No.: 986693-B       ,
Engineer Deihimi,, Amir Hossein; Lic. No.: NA78194       ,

Inspector Information

RONNIE MINDANAO, (213) 202-3252 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 2/23/2024 Approved RICHARD DOCKUS
Deputy Drilled-In Anchors 8/1/2024 Conditional Approval RONNIE MINDANAO
Pre-Inspection 9/16/2024 Partial Inspection RONNIE MINDANAO
Interior/Exterior Lathing 9/27/2024 Approved RONNIE MINDANAO
BUILDING-Rough-Frame 10/11/2024 Not Ready for Inspection JUSTIN HAWLEY
BUILDING-Rough-Frame 11/22/2024 Not Ready for Inspection RONNIE MINDANAO
ELECTRICAL-Rough 11/22/2024 Corrections Issued RONNIE MINDANAO
HVAC-Rough 11/22/2024 Not Ready for Inspection RONNIE MINDANAO
PLUMBING-Rough 11/22/2024 Not Ready for Inspection RONNIE MINDANAO
HVAC-Rough 11/26/2024 Approved JEFFREY MEAD
PLUMBING-Rough 11/27/2024 Approved RONNIE MINDANAO
ELECTRICAL-Rough 12/6/2024 Corrections Issued RONNIE MINDANAO
BUILDING-Rough-Frame 12/11/2024 Approved RONNIE MINDANAO
Insulation 1/13/2025 Not Ready for Inspection RONNIE MINDANAO
Insulation 1/23/2025 Corrections Issued RONNIE MINDANAO
Insulation 2/19/2025 Corrections Issued JEFFREY MEAD
Insulation 2/21/2025 Approved ENRIQUE MIRELES
Drywall Nailing 2/28/2025 Partial Approval RONNIE MINDANAO
Drywall Nailing 3/14/2025 Partial Approval RONNIE MINDANAO
Drywall Nailing 3/19/2025 Approved RONNIE MINDANAO
Interior/Exterior Lathing 3/28/2025 Approved RONNIE MINDANAO
Shower Pan 3/28/2025 Approved RONNIE MINDANAO
PLUMBING-Final 6/6/2025 Corrections Issued RONNIE MINDANAO
ELECTRICAL-Final 6/18/2025 Corrections Issued RONNIE MINDANAO
HVAC-Final 6/20/2025 Approved RONNIE MINDANAO
ELECTRICAL-Final 6/24/2025 Corrections Issued RONNIE MINDANAO
Final 6/24/2025 Corrections Issued RONNIE MINDANAO
SGSOV-Seismic Gas S/O Valve 6/24/2025 SGSOV Approved RONNIE MINDANAO
Smoke Detectors 6/24/2025 Approved RONNIE MINDANAO
ELECTRICAL-Final 6/26/2025 Approved RONNIE MINDANAO
Final 6/30/2025 Permit Finaled ARTHUR NEGRETE
PLUMBING-Final 6/30/2025 Approved ARTHUR NEGRETE