4335 N MANSON AVE 91364
Certificate Information: 4335 N MANSON AVE 91364
- Application / Permit
- 23014-20000-04225
- Plan Check / Job No.
- B23VN14150
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePlan: (N) addition to existing S.F.D.
- Permit Issued
- Issued on 3/22/2024
- Issuing Office
- Current Status
- CofO Corrected on 4/17/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/24/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 10/25/2023 | ALFREDO JARA |
| Corrections Issued | 10/25/2023 | ALFREDO JARA |
| Applicant returned to address corrections | 11/8/2023 | JAHANSHAH POURHASSAN |
| Applicant returned to address corrections | 12/13/2023 | EDWIN ESPIN |
| Applicant returned to address corrections | 1/3/2024 | EDWIN ESPIN |
| Plan Check Approved | 3/14/2024 | CAROLEAN BASMA |
| Issued | 3/22/2024 | APPLICANT |
| CofO in Progress | 10/21/2024 | JOHN HAYES |
| No Progress | 1/30/2025 | SEAN WIRCH |
| CofO in Progress | 1/30/2025 | SEAN WIRCH |
| Re-Activate Permit | 4/17/2026 | JOHN JANSON |
| CofO Issued-Status Void | 4/17/2026 | JOHN JANSON |
| Permit Finaled-Status Void | 4/17/2026 | JOHN JANSON |
| Permit Finaled | 4/17/2026 | JOHN JANSON |
| CofO Corrected | 4/17/2026 | JOHN JANSON |
| Permit Finaled | 4/17/2026 | JOHN JANSON |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 11/29/2023 | CARLOS RAMIREZ |
| Eng Process Fee Ord 176,300 | Cleared | 11/30/2023 | CARLOS RAMIREZ |
| Sewer availability | Cleared | 1/16/2024 | CARLOS RAMIREZ |
| Grading Pre-Inspection | Cleared | 3/2/2024 | CHARLES POWELL |
Contact Information
| Contractor | Legacy Builders & Development Llc; Lic. No.: 1113312-B | , |
| Engineer | Reith,, David Lee; Lic. No.: C72122 | 1319 FEATHER AVE THOUSAND OAKS, CA 91360 |
Inspector Information
| JOHN HAYES, (818) 774-4302 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 5/3/2024 | Corrections Issued | MORRIS JACKSON |
| Pre-Inspection | 5/3/2024 | Partial Inspection | MORRIS JACKSON |
| Underground Mechanical | 5/3/2024 | Approved | MORRIS JACKSON |
| Deputy Other (see comments) | 5/6/2024 | Conditional Approval | HENRY KIM |
| Footing/Foundation/Slab | 5/16/2024 | Approved | MORRIS JACKSON |
| Pre-Inspection | 5/28/2024 | Corrections Issued | JOHN HAYES |
| BUILDING-Rough-Frame | 6/3/2024 | Corrections Issued | JOHN HAYES |
| Floor/Roof Diaphrgm/Shear Wall | 6/3/2024 | Partial Approval | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 6/3/2024 | Not Ready for Inspection | JOHN HAYES |
| Deputy Wood Construction | 6/5/2024 | Conditional Approval | JOHN HAYES |
| BUILDING-Rough-Frame | 6/11/2024 | Approved | JOHN HAYES |
| Green Building Rough | 6/11/2024 | Not Ready for Inspection | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 6/11/2024 | Approved | JOHN HAYES |
| Interior/Exterior Lathing | 6/24/2024 | Partial Approval | HORACE FULTZ |
| Insulation | 6/28/2024 | Approved | JOHN HAYES |
| Drywall Nailing | 7/8/2024 | Approved | JOHN HAYES |
| Sewer | 9/5/2024 | Corrections Issued | JOHN HAYES |
| Sewer | 9/9/2024 | Corrections Issued | JOHN HAYES |
| Sewer | 9/13/2024 | Approved | JOHN HAYES |
| Final | 10/1/2024 | Corrections Issued | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 10/1/2024 | SGSOV Approved | JOHN HAYES |
| Smoke Detectors | 10/1/2024 | Approved | JOHN HAYES |
| Final | 10/21/2024 | OK to Issue CofO | JOHN HAYES |