10447 N WOODLEY AVE 91344
Certificate Information: 10447 N WOODLEY AVE 91344
- Application / Permit
- 23014-20000-04211
- Plan Check / Job No.
- B23VN14080
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- eplan Convert existing garage 400 SF into ADU and add 225 SF to the proposed ADU. PER CA Govt. Code 65852.2(e)(1)(B) and applicable part2 of LAMC 12.22 A.33 (c)-(d), (g)
- Permit Issued
- Issued on 1/5/2024
- Issuing Office
- Current Status
- CofO Issued on 7/8/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/13/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 10/17/2023 | ALFREDO JARA |
| Corrections Issued | 10/17/2023 | ALFREDO JARA |
| Applicant returned to address corrections | 11/17/2023 | ALFREDO JARA |
| Plan Check Approved | 1/4/2024 | JASON JANGADA |
| Issued | 1/5/2024 | APPLICANT |
| CofO in Progress | 6/25/2025 | NICHOLAS TROWBRIDGE |
| Permit Finaled | 7/8/2025 | RUBEN SALAS |
| CofO Issued | 7/8/2025 | RUBEN SALAS |
| Permit Finaled | 7/8/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 11/15/2023 | CARLOS RAMIREZ |
| Eng Process Fee Ord 176,300 | Cleared | 11/15/2023 | CARLOS RAMIREZ |
| Roof/Waste drainage to street | Cleared | 11/15/2023 | CARLOS RAMIREZ |
| Sewer availability | Cleared | 11/16/2023 | CARLOS RAMIREZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Castillo,, Margarito; Lic. No.: NA4808 | , |
Inspector Information
| CHRISTOPHER ROJAS, (818) 374-1160 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 2/29/2024 | Partial Approval | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 4/17/2024 | Approved | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 5/8/2024 | Partial Inspection | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 5/8/2024 | Corrections Issued | JAVIER RAMOS JR |
| Green Building Rough | 5/8/2024 | Not Ready for Inspection | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 5/8/2024 | Partial Approval | JAVIER RAMOS JR |
| PLUMBING-Rough | 5/8/2024 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 5/28/2024 | Corrections Issued | KEVIN BERBERYAN |
| HVAC-Rough | 5/28/2024 | Corrections Issued | KEVIN BERBERYAN |
| BUILDING-Rough-Frame | 6/20/2024 | Partial Approval | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 6/20/2024 | Approved | JAVIER RAMOS JR |
| Green Building Rough | 6/20/2024 | Approved | JAVIER RAMOS JR |
| HVAC-Rough | 6/20/2024 | Corrections Issued | JAVIER RAMOS JR |
| Insulation | 6/25/2024 | Approved | JAVIER RAMOS JR |
| Drywall Nailing | 7/18/2024 | Approved | JAVIER RAMOS JR |
| Shower Pan | 7/18/2024 | Approved | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 8/21/2024 | Approved | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 9/25/2024 | Approved | JAVIER RAMOS JR |
| Final | 9/25/2024 | Corrections Issued | JAVIER RAMOS JR |
| Footing/Foundation/Slab | 9/25/2024 | Approved | JAVIER RAMOS JR |
| Green Building Final | 9/25/2024 | Not Ready for Inspection | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 9/25/2024 | SGSOV Approved | JAVIER RAMOS JR |
| Smoke Detectors | 9/25/2024 | Not Ready for Inspection | JAVIER RAMOS JR |
| Final | 11/1/2024 | No Access for Inspection | JAVIER RAMOS JR |
| ELECTRICAL-Final | 6/20/2025 | Corrections Issued | NICHOLAS TROWBRIDGE |
| Final | 6/20/2025 | Not Ready for Inspection | NICHOLAS TROWBRIDGE |
| Green Building Final | 6/20/2025 | Approved | NICHOLAS TROWBRIDGE |
| HVAC-Final | 6/20/2025 | Approved | NICHOLAS TROWBRIDGE |
| PLUMBING-Final | 6/20/2025 | Approved | NICHOLAS TROWBRIDGE |
| Smoke Detectors | 6/20/2025 | Approved | NICHOLAS TROWBRIDGE |
| Final | 6/24/2025 | OK to Issue CofO | NICHOLAS TROWBRIDGE |