4875-4877 N CANOGA AVE 91364
Certificate Information: 4875-4877 N CANOGA AVE 91364
- Application / Permit
- 23014-20000-03941
- Plan Check / Job No.
- B23VN13164
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePlan: NEW ATTACHED A.D.U. PER LAMC 12.22 A.33(c) and (e). DESIGN PER LICENSED ENGINEER.
- Permit Issued
- Issued on 2/26/2024
- Issuing Office
- Current Status
- CofO Issued on 3/11/2026
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/28/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 9/29/2023 | AMY GUEVARRA |
| Corrections Issued | 10/3/2023 | AMY GUEVARRA |
| Applicant returned to address corrections | 2/15/2024 | AMY GUEVARRA |
| Applicant returned to address corrections | 2/22/2024 | CAROLEAN BASMA |
| Plan Check Approved | 2/25/2024 | CAROLEAN BASMA |
| Issued | 2/26/2024 | APPLICANT |
| CofO in Progress | 4/9/2025 | JOHN HAYES |
| No Progress | 4/21/2025 | SEAN WIRCH |
| CofO in Progress | 4/21/2025 | SEAN WIRCH |
| Permit Finaled | 3/11/2026 | JOHN JANSON |
| CofO Issued | 3/11/2026 | JOHN JANSON |
| Permit Finaled | 3/11/2026 | JOHN JANSON |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 10/2/2023 | AMY GUEVARRA |
| Address approval | Cleared | 10/3/2023 | KHAING AYE |
| City Hist. Cultural Monument | Cleared | 10/4/2023 | LAMBERT GIESSINGER |
| Historic monument | Cleared | 10/4/2023 | LAMBERT GIESSINGER |
| Construction near power lines | Cleared | 2/8/2024 | RIDWAN HARDY |
| Low Impact Development (LID) | Cleared | 2/12/2024 | TOMMY YIN |
| Eng Process Fee Ord 176,300 | Cleared | 2/13/2024 | COLIN LOREDO |
| Roof/Waste drainage to street | Cleared | 2/13/2024 | COLIN LOREDO |
| Sewer availability | Cleared | 2/13/2024 | COLIN LOREDO |
| ZI | Cleared | 2/13/2024 | TIFFANY CORRALES |
Contact Information
| Contractor | Better Together Builders Inc; Lic. No.: 1047689-B | , |
| Engineer | Dominguez,, Refugio; Lic. No.: NA50820 | , |
Inspector Information
| JOHN HAYES, (818) 774-4302 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 4/9/2024 | Corrections Issued | MORRIS JACKSON |
| Footing/Foundation/Slab | 5/1/2024 | Corrections Issued | MORRIS JACKSON |
| Footing/Foundation/Slab | 5/9/2024 | Approved | MORRIS JACKSON |
| PLUMBING-Rough | 5/17/2024 | Corrections Issued | JOHN HAYES |
| BUILDING-Rough-Frame | 5/21/2024 | Partial Approval | JOHN HAYES |
| Green Building Rough | 5/21/2024 | Not Ready for Inspection | JOHN HAYES |
| PLUMBING-Rough | 5/21/2024 | Partial Approval | JOHN HAYES |
| BUILDING-Rough-Frame | 8/8/2024 | Not Ready for Inspection | JOHN HAYES |
| Green Building Rough | 8/8/2024 | Not Ready for Inspection | JOHN HAYES |
| Insulation | 8/12/2024 | Partial Approval | ARUTYUN MADATYAN |
| Floor/Roof Diaphrgm/Shear Wall | 8/14/2024 | Partial Approval | JEFFREY HARTLINE |
| Floor/Roof Diaphrgm/Shear Wall | 8/29/2024 | Partial Approval | JOHN HAYES |
| BUILDING-Rough-Frame | 9/10/2024 | Corrections Issued | JOHN HAYES |
| ELECTRICAL-Rough | 9/10/2024 | Not Ready for Inspection | JOHN HAYES |
| Green Building Rough | 9/10/2024 | Not Ready for Inspection | JOHN HAYES |
| PLUMBING-Rough | 9/10/2024 | Approved | JOHN HAYES |
| BUILDING-Rough-Frame | 9/20/2024 | Partial Approval | JOHN HAYES |
| Green Building Rough | 9/20/2024 | Not Ready for Inspection | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 9/20/2024 | Partial Approval | JOHN HAYES |
| Shower Pan | 9/20/2024 | Approved | JOHN HAYES |
| BUILDING-Rough-Frame | 9/30/2024 | Approved | JOHN HAYES |
| Floor/Roof Diaphrgm/Shear Wall | 9/30/2024 | Approved | JOHN HAYES |
| Green Building Rough | 9/30/2024 | Approved | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 9/30/2024 | Approved | JOHN HAYES |
| Insulation | 10/9/2024 | Corrections Issued | JOHN HAYES |
| Insulation | 10/11/2024 | Approved | JOHN HAYES |
| Drywall Nailing | 10/18/2024 | Approved | JOHN HAYES |
| Final | 12/30/2024 | Corrections Issued | JOHN HAYES |
| Green Building Final | 12/30/2024 | Approved | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 12/30/2024 | SGSOV Approved | JOHN HAYES |
| Smoke Detectors | 12/30/2024 | Approved | JOHN HAYES |
| Final | 4/1/2025 | Corrections Issued | JOHN COLEMAN |
| Final | 4/4/2025 | Corrections Issued | JOHN HAYES |
| Final | 4/9/2025 | OK to Issue CofO | JOHN HAYES |
| Special/Order Compliance | 4/22/2025 | Corrections Issued | JOHN HAYES |