7874 N CLEARFIELD AVE 91402
Certificate Information: 7874 N CLEARFIELD AVE 91402
- Application / Permit
- 23014-20000-02651
- Plan Check / Job No.
- B23VN08823
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 7'-6" X 30'-5" ADDITION AND REMODEL TO ENLARGE LIVING ROOM AND BEDROOM, AND ADD ONE NEW BATHROOM. ALL WORK PER ENG.
- Permit Issued
- Issued on 8/14/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 6/26/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/3/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 7/7/2023 | JEROME MAGAT PALMA |
| Corrections Issued | 7/8/2023 | JEROME MAGAT PALMA |
| Building Plans Picked Up | 7/14/2023 | APPLICANT |
| Applicant returned to address corrections | 8/11/2023 | GIOVANNY CHAVEZ |
| Issued | 8/14/2023 | APPLICANT |
| CofO in Progress | 6/13/2024 | VINCENT HANLEY |
| Permit Finaled | 6/26/2024 | RUBEN SALAS |
| Permit Finaled | 6/26/2024 | RUBEN SALAS |
| CofO Issued | 6/26/2024 | RUBEN SALAS |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 7/17/2023 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 7/18/2023 | LEE GUILBEAUX |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Cristescu,, Barbu Dan; Lic. No.: C72038 | 14401 SYLVAN STREET 209 VAN NUYS, CA 91401 |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 9/1/2023 | Conditional Approval | DAVID MATSON |
| Footing/Foundation/Slab | 9/1/2023 | Corrections Issued | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 11/6/2023 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 11/6/2023 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 11/6/2023 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 11/27/2023 | Partial Approval | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 12/1/2023 | Partial Approval | THOMAS FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 12/11/2023 | Not Ready for Inspection | GREGG CUMMINGS |
| Gas Test | 12/11/2023 | Not Ready for Inspection | GREGG CUMMINGS |
| Insulation | 12/11/2023 | Not Ready for Inspection | GREGG CUMMINGS |
| Wood Frame | 12/11/2023 | Not Ready for Inspection | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 12/12/2023 | No Access for Inspection | CHRISTOPHER ROJAS |
| Floor/Roof Diaphrgm/Shear Wall | 12/18/2023 | Corrections Issued | CHRISTOPHER ROJAS |
| Wood Frame | 12/18/2023 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Floor/Roof Diaphrgm/Shear Wall | 12/20/2023 | Not Ready for Inspection | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 12/22/2023 | Partial Approval | GREGG CUMMINGS |
| ELECTRICAL-Rough | 1/8/2024 | Corrections Issued | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 1/8/2024 | Corrections Issued | GREGG CUMMINGS |
| HVAC-Rough | 1/8/2024 | Corrections Issued | GREGG CUMMINGS |
| ELECTRICAL-Rough | 1/17/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 1/17/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Rough | 3/13/2024 | Approved | GREGG CUMMINGS |
| HVAC-Rough | 3/13/2024 | Approved | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 3/15/2024 | Approved | GREGG CUMMINGS |
| Green Building Rough | 3/15/2024 | Approved | GREGG CUMMINGS |
| Shower Pan | 3/15/2024 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 3/20/2024 | Approved | GREGG CUMMINGS |
| Insulation | 3/20/2024 | Approved | GREGG CUMMINGS |
| Drywall Nailing | 3/26/2024 | Approved | KIRK SANDERS |
| Interior/Exterior Lathing | 3/29/2024 | Approved | GREGG CUMMINGS |
| Final | 5/24/2024 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 5/24/2024 | Approved | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 5/24/2024 | SGSOV Not Ready | GREGG CUMMINGS |
| Smoke Detectors | 5/24/2024 | Approved | GREGG CUMMINGS |
| Final | 5/31/2024 | Corrections Issued | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 5/31/2024 | SGSOV Not Ready | GREGG CUMMINGS |
| ELECTRICAL-Final | 6/12/2024 | Approved | VINCENT HANLEY |
| Final | 6/12/2024 | OK to Issue CofO | VINCENT HANLEY |
| HVAC-Final | 6/12/2024 | Approved | VINCENT HANLEY |
| PLUMBING-Final | 6/12/2024 | Approved | VINCENT HANLEY |
| SGSOV-Seismic Gas S/O Valve | 6/12/2024 | SGSOV Approved | VINCENT HANLEY |