10501 W CANTARA ST 91352

Certificate Information: 10501 W CANTARA ST 91352

Application / Permit
23014-20000-01718
Plan Check / Job No.
B23VN05690
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
eplan: 10' X 22' Addition to Existing sfd and interior remodel, ALL WORK PER WFPP
Permit Issued
Issued on 7/28/2023
Issuing Office
Current Status
CofO in Progress on 11/25/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 5/3/2023 APPLICANT
Assigned to Plan Check Engineer 5/8/2023 LUISANGEL VALENZUELA
Corrections Issued 5/9/2023 LUISANGEL VALENZUELA
Applicant returned to address corrections 5/20/2023 LUISANGEL VALENZUELA
Plan Check Approved 7/13/2023 JOSEPH RAFOLS
Issued 7/28/2023 APPLICANT
CofO in Progress 11/25/2025 DAVID ANDERSON
CofO in Progress 1/30/2026 DAVID ANDERSON

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 5/12/2023 LEE GUILBEAUX
Sewer availability Cleared 5/12/2023 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 5/18/2023 CARLOS AGUILERA

Contact Information

Contractor Owner-Builder       ,

Inspector Information

DAVID ANDERSON, (818) 374-1168 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 11/22/2023 Corrections Issued DAVID ANDERSON
PLUMBING-Rough 3/4/2024 Partial Approval DAVID ANDERSON
Floor/Roof Diaphrgm/Shear Wall 3/6/2024 Partial Approval DAVID ANDERSON
Insulation 3/6/2024 Partial Approval DAVID ANDERSON
MERV13>=Rough 3/6/2024 Not Ready for Inspection DAVID ANDERSON
Floor/Roof Diaphrgm/Shear Wall 5/23/2024 Not Ready for Inspection DAVID ANDERSON
MERV13>=Rough 5/23/2024 Not Ready for Inspection DAVID ANDERSON
Rough-Elec/Plmb/HVAC 9/18/2024 Corrections Issued DAVID ANDERSON
BUILDING-Rough-Frame 10/7/2024 Not Ready for Inspection DAVID ANDERSON
ELECTRICAL-Rough 10/7/2024 Corrections Issued DAVID ANDERSON
MERV13>=Rough 10/7/2024 Not Ready for Inspection DAVID ANDERSON
PLUMBING-Rough 10/7/2024 Corrections Issued DAVID ANDERSON
BUILDING-Rough-Frame 10/10/2024 Approved DAVID ANDERSON
ELECTRICAL-Rough 10/10/2024 Approved DAVID ANDERSON
HVAC-Rough 10/10/2024 Approved DAVID ANDERSON
Interior/Exterior Lathing 10/10/2024 Partial Approval DAVID ANDERSON
MERV13>=Rough 10/10/2024 Approved DAVID ANDERSON
PLUMBING-Rough 10/10/2024 Approved DAVID ANDERSON
Insulation 10/23/2024 Corrections Issued DAVID ANDERSON
Sewer 10/23/2024 Approved DAVID ANDERSON
Drywall Nailing 11/1/2024 Approved DAVID ANDERSON
Insulation 11/1/2024 Approved DAVID ANDERSON
Interior/Exterior Lathing 11/18/2024 Approved DAVID ANDERSON
Shower Pan 11/18/2024 Approved DAVID ANDERSON
Final 2/11/2025 Corrections Issued DAVID ANDERSON
Footing/Foundation/Slab 2/11/2025 Approved DAVID ANDERSON
MERV13>=Final 2/11/2025 Approved DAVID ANDERSON
SGSOV-Seismic Gas S/O Valve 2/11/2025 SGSOV Approved DAVID ANDERSON
Smoke Detectors 2/11/2025 Corrections Issued DAVID ANDERSON
Pre-Inspection 11/10/2025 Not Ready for Inspection KEVIN BERBERYAN
ELECTRICAL-Final 11/24/2025 Approved DAVID ANDERSON
Final 11/24/2025 Not Ready for Inspection DAVID ANDERSON
Smoke Detectors 11/24/2025 Approved DAVID ANDERSON