234 S WESTGATE AVE 90049

Certificate Information: 234 S WESTGATE AVE 90049

Application / Permit
23014-20000-01680
Plan Check / Job No.
B23VN05543
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
16'-2" x 8'-7"ADDITION TO (E) SFD AND REMODEL TO (E) SFD. WORK DONE PER ENGINEERING.
Permit Issued
Issued on 7/7/2023
Issuing Office
Current Status
CofO Issued on 12/26/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 5/1/2023 APPLICANT
Assigned to Plan Check Engineer 5/4/2023 JEROME MAGAT PALMA
Corrections Issued 5/5/2023 JEROME MAGAT PALMA
Building Plans Picked Up 5/8/2023 APPLICANT
Applicant returned to address corrections 6/30/2023 ISIS ARGUETA
Plan Check Approved 7/7/2023 MIROOSH KHACHATOORIAN
Issued 7/7/2023 APPLICANT
CofO in Progress 12/21/2024 MICHAEL PELHAM
Permit Finaled 12/26/2024 RICHARD STEINBACH
CofO Issued 12/26/2024 RICHARD STEINBACH
Permit Finaled 12/26/2024 RICHARD STEINBACH

Permit Application Clearance Information

Sewer availability Cleared 5/10/2023 DARIN LAM
Miscellaneous Cleared 5/11/2023 MAXFIELD VERMY
Grading Pre-Inspection Cleared 6/5/2023 SERGIO VALENZUELA
Specific Plan Cleared 6/7/2023 FREDDY GARCIA
Eng Process Fee Ord 176,300 Cleared 6/26/2023 ANTHONY MAINEZ
Roof/Waste drainage to street Cleared 6/26/2023 ANTHONY MAINEZ

Contact Information

Contractor Oag; Lic. No.: 1101018-B 9712 LIVE OAK AVE      TEMPLE CITY, CA 91780
Engineer Standley,, Craig Erick; Lic. No.: C87675 60 VIA CARATAMA      SAN CLEMENTE, CA 92673

Inspector Information

EVAN COOPER, (310) 914-3861 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 8/4/2023 Partial Approval CARLOS MATAMOROS
Underground Mechanical 8/4/2023 Approved CARLOS MATAMOROS
Deputy Drilled-In Anchors 8/8/2023 Conditional Approval MICHAEL PELHAM
Footing/Foundation/Slab 8/9/2023 Approved CARLOS MATAMOROS
ELECTRICAL-Rough 8/21/2023 Partial Approval CARLOS MATAMOROS
Shower Pan 8/21/2023 Approved CARLOS MATAMOROS
Drywall Nailing 8/29/2023 Not Ready for Inspection CARLOS MATAMOROS
Interior/Exterior Lathing 8/29/2023 Approved CARLOS MATAMOROS
Floor/Roof Diaphrgm/Shear Wall 2/12/2024 Approved CARLOS MATAMOROS
Floor/Roof Diaphrgm/Shear Wall 2/15/2024 Not Ready for Inspection CARLOS MATAMOROS
Floor/Roof Diaphrgm/Shear Wall 2/22/2024 Approved CARLOS MATAMOROS
Underground Mechanical 2/22/2024 Approved CARLOS MATAMOROS
Floor/Roof Diaphrgm/Shear Wall 4/17/2024 Conditional Approval CARLOS MATAMOROS
ELECTRICAL-Rough 4/19/2024 Not Ready for Inspection CARLOS MATAMOROS
PLUMBING-Rough 4/19/2024 Not Ready for Inspection CARLOS MATAMOROS
ELECTRICAL-Rough 4/29/2024 Corrections Issued STEPHANIE SWANSON
Interior/Exterior Lathing 4/29/2024 Partial Approval STEPHANIE SWANSON
PLUMBING-Rough 4/29/2024 Corrections Issued STEPHANIE SWANSON
ELECTRICAL-Rough 5/3/2024 Corrections Issued CARLOS MATAMOROS
PLUMBING-Rough 5/3/2024 Corrections Issued CARLOS MATAMOROS
BUILDING-Rough-Frame 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
ELECTRICAL-Rough 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
Green Building Rough 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
HVAC-Rough 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
PLUMBING-Rough 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
Shower Pan 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
Wood Frame 5/10/2024 Not Ready for Inspection CARLOS MATAMOROS
ELECTRICAL-Rough 5/14/2024 Approved CARLOS MATAMOROS
PLUMBING-Rough 5/15/2024 Corrections Issued MICHAEL PELHAM
BUILDING-Rough-Frame 5/17/2024 Not Ready for Inspection CARLOS MATAMOROS
Green Building Rough 5/17/2024 Approved CARLOS MATAMOROS
PLUMBING-Rough 5/17/2024 Corrections Issued CARLOS MATAMOROS
ELECTRICAL-Rough 5/20/2024 Approved CARLOS MATAMOROS
HVAC-Rough 5/20/2024 Approved CARLOS MATAMOROS
PLUMBING-Rough 5/20/2024 Approved CARLOS MATAMOROS
Wood Frame 5/20/2024 Approved CARLOS MATAMOROS
Insulation 5/24/2024 Corrections Issued ARAM AVEDISIAN
Insulation 5/31/2024 Approved TEMISTOCLES CAAL
Drywall Nailing 6/4/2024 Approved MEL KHACHATOURIAN
Interior/Exterior Lathing 6/4/2024 Approved MEL KHACHATOURIAN
BUILDING-Rough-Frame 10/15/2024 Approved CARLOS MATAMOROS
Final 10/15/2024 Corrections Issued CARLOS MATAMOROS
Green Building Final 10/15/2024 Approved CARLOS MATAMOROS
SGSOV-Seismic Gas S/O Valve 10/15/2024 SGSOV Approved CARLOS MATAMOROS
Smoke Detectors 10/15/2024 Corrections Issued CARLOS MATAMOROS
Final 11/25/2024 OK to Issue CofO CARLOS MATAMOROS
Smoke Detectors 11/25/2024 Approved CARLOS MATAMOROS
PLUMBING-Final 11/26/2024 Approved CARLOS MATAMOROS