4457 E YELLOWSTONE ST 90032

Certificate Information: 4457 E YELLOWSTONE ST 90032

Application / Permit
23014-20000-00762
Plan Check / Job No.
B23VN02465
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 13'-3" X 10'-2" ADDITION TO AND CONVERT DETACHED GARAGE INTO A (N) IRREGULAR SHAPED 33'-3" x 18'-3" ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d)
Permit Issued
Issued on 8/10/2023
Issuing Office
Valley
Current Status
CofO Issued on 12/6/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/28/2023 APPLICANT
Assigned to Plan Check Engineer 3/3/2023 JEROME MAGAT PALMA
Corrections Issued 3/4/2023 JEROME MAGAT PALMA
Building Plans Picked Up 3/7/2023 APPLICANT
Applicant returned to address corrections 7/21/2023 KAMYAR EMAMI
Applicant returned to address corrections 7/25/2023 GIOVANNY CHAVEZ
Plan Check Approved 7/31/2023 ALFRED RAMIREZ
Issued 8/10/2023 APPLICANT
CofO in Progress 12/4/2025 LILIANA PORTILLO
Permit Finaled 12/6/2025 DEROLD HAUFF
CofO Issued 12/6/2025 DEROLD HAUFF
Permit Finaled 12/6/2025 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 4/11/2023 CINDY QI
Roof/Waste drainage to street Cleared 4/11/2023 CINDY QI
Eng Process Fee Ord 176,300 Cleared 4/17/2023 CINDY QI
Sewer availability Cleared 4/17/2023 CINDY QI
Construction near power lines Cleared 6/5/2023 RIDWAN HARDY
Grading Pre-Inspection Cleared 6/9/2023 SERGIO VALENZUELA
"D" conditions Cleared 7/15/2023 RYAN LY
"Q" conditions Cleared 7/15/2023 RYAN LY
ZI Cleared 7/15/2023 RYAN LY

Contact Information

Contractor Adar Builders Inc; Lic. No.: 1051859-B 7673 WINNETKA AVENUE      WINNETKA, CA 91306
Engineer Dominguez,, Refugio; Lic. No.: C50820 254 COTTONWOOD ST      ONTARIO, CA 91761

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 8/25/2023 Partial Approval AMY COLIN
Footing/Foundation/Slab 8/31/2023 Approved AMY COLIN
BUILDING-Rough-Frame 9/13/2023 Corrections Issued AMY COLIN
ELECTRICAL-Rough 9/13/2023 Approved AMY COLIN
Green Building Rough 9/13/2023 Not Ready for Inspection AMY COLIN
HVAC-Rough 9/13/2023 Not Ready for Inspection AMY COLIN
PLUMBING-Rough 9/13/2023 Approved AMY COLIN
Insulation 9/20/2023 Corrections Issued AMY COLIN
Interior/Exterior Lathing 9/28/2023 Partial Approval AMY COLIN
Wood Frame 9/28/2023 Partial Approval AMY COLIN
Drywall Nailing 10/3/2023 Approved AMY COLIN
Sewer 10/16/2023 Corrections Issued AMY COLIN
Sewer 10/18/2023 Approved AMY COLIN
Interior/Exterior Lathing 11/1/2023 Approved AMY COLIN
BUILDING-Rough-Frame 11/15/2023 Approved ROY SPAULDING
Final 11/15/2023 Corrections Issued ROY SPAULDING
Green Building Final 11/15/2023 Partial Approval ROY SPAULDING
Green Building Rough 11/15/2023 Approved ROY SPAULDING
SGSOV-Seismic Gas S/O Valve 11/15/2023 SGSOV Approved ROY SPAULDING
Smoke Detectors 11/15/2023 Approved ROY SPAULDING
Final 11/29/2023 Corrections Issued AMY COLIN
Green Building Final 11/29/2023 Approved AMY COLIN
Final 8/29/2024 Not Ready for Inspection LILIANA PORTILLO
Final 12/3/2025 OK to Issue CofO LILIANA PORTILLO