1622 1/2 N MORTON AVE 90026
Certificate Information: 1622 1/2 N MORTON AVE 90026
- Application / Permit
- 23014-10000-05205
- Plan Check / Job No.
- B23LA23932
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- *eplan* ADDITION AND CONVERT (E) GARAGE TO ADU PER CA GOVT. CODE 65852.2(E)(1)(D) & APPLICABLE PART 2 OF LAMC 12.22 A.33(C)(D) & (G)
- Permit Issued
- Issued on 6/3/2024
- Issuing Office
- Current Status
- CofO Corrected on 7/29/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/19/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 1/11/2024 | JAD BASMA |
| Corrections Issued | 1/17/2024 | JAD BASMA |
| Quality Review Completed | 1/19/2024 | GARO TELMI |
| Plan Check Approved | 5/30/2024 | JAD BASMA |
| Issued | 6/3/2024 | APPLICANT |
| CofO in Progress | 7/18/2025 | HAMIK HARTOUNIAN |
| CofO Issued-Status Void | 7/21/2025 | DEROLD HAUFF |
| Permit Finaled-Status Void | 7/21/2025 | DEROLD HAUFF |
| Re-Activate Permit | 7/29/2025 | DEROLD HAUFF |
| Permit Finaled | 7/29/2025 | DEROLD HAUFF |
| CofO Corrected | 7/29/2025 | DEROLD HAUFF |
| Permit Finaled | 7/29/2025 | DEROLD HAUFF |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 1/18/2024 | TREVOR QUAN |
| Roof/Waste drainage to street | Cleared | 1/18/2024 | TREVOR QUAN |
| Sewer availability | Cleared | 1/18/2024 | TREVOR QUAN |
| Street Frontage | Cleared | 1/18/2024 | TREVOR QUAN |
| Address approval | Cleared | 4/8/2024 | CHRISTINA BRACO |
| GPI Written Notices | Cleared | 5/17/2024 | JAD BASMA |
| Grading Pre-Inspection | Cleared | 5/17/2024 | JAD BASMA |
Contact Information
| Contractor | Adea Builders; Lic. No.: 1067670-B | , |
| Contractor | Armenella; Lic. No.: 1067670-B | , |
| Engineer | Garcia,, Francisco Javier; Lic. No.: NA76510 | , |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 6/24/2024 | Partial Approval | SCOTT FINNILA |
| Deputy Drilled-In Anchors | 6/28/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| Excavation/Setback/Form/Re-Bar | 7/1/2024 | Approved | HAMIK HARTOUNIAN |
| Deputy Drilled-In Anchors | 7/16/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/17/2024 | Partial Approval | HAMIK HARTOUNIAN |
| Deputy Drilled-In Anchors | 7/31/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 8/13/2024 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 8/13/2024 | Approved | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 8/15/2024 | Not Ready for Inspection | CRAIG VAUGHAN |
| HVAC-Rough | 8/15/2024 | Approved | CRAIG VAUGHAN |
| Wood Frame | 8/15/2024 | Not Ready for Inspection | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 8/20/2024 | Partial Approval | LUIS CASTRO |
| Green Building Rough | 8/20/2024 | Not Ready for Inspection | LUIS CASTRO |
| Insulation | 8/21/2024 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Insulation | 8/30/2024 | Not Ready for Inspection | ANTHONY RAMOS |
| Interior/Exterior Lathing | 8/30/2024 | Not Ready for Inspection | ANTHONY RAMOS |
| Insulation | 9/3/2024 | Not Ready for Inspection | ROY SPAULDING |
| Interior/Exterior Lathing | 9/3/2024 | Not Ready for Inspection | ROY SPAULDING |
| Pre-Inspection | 9/5/2024 | Corrections Issued | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 9/11/2024 | Partial Approval | LUIS CASTRO |
| Insulation | 9/11/2024 | Approved | LUIS CASTRO |
| Interior/Exterior Lathing | 9/11/2024 | Approved | LUIS CASTRO |
| BUILDING-Rough-Frame | 9/19/2024 | Approved | HAMIK HARTOUNIAN |
| Drywall Nailing | 9/19/2024 | Approved | HAMIK HARTOUNIAN |
| Green Building Rough | 9/19/2024 | Approved | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 10/24/2024 | Partial Approval | LUIS CASTRO |
| Underground Mechanical | 10/24/2024 | Partial Approval | LUIS CASTRO |
| Pre-Inspection | 12/12/2024 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 1/28/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 1/31/2025 | Approved | OSVALDO PARAMO |
| ELECTRICAL-Final | 6/9/2025 | Corrections Issued | FREDDIE RIVERA |
| Final | 6/9/2025 | Corrections Issued | FREDDIE RIVERA |
| Green Building Final | 6/9/2025 | Corrections Issued | FREDDIE RIVERA |
| SGSOV-Seismic Gas S/O Valve | 6/9/2025 | SGSOV Approved | FREDDIE RIVERA |
| Smoke Detectors | 6/9/2025 | Approved | FREDDIE RIVERA |
| Final | 6/13/2025 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Green Building Final | 6/13/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| Final | 6/18/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| Green Building Final | 6/18/2025 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Final | 7/18/2025 | OK to Issue CofO | HAMIK HARTOUNIAN |
| Green Building Final | 7/18/2025 | Approved | HAMIK HARTOUNIAN |