6123 W WARNER DR 90048

Certificate Information: 6123 W WARNER DR 90048

Application / Permit
23014-10000-04890
Plan Check / Job No.
B23LA22649
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
eplan. 76 SF ADDITION TO CONNECT (E) DETACHED ACCESSORY LIVING QUARTERS/GARAGE AND DETACHED UNPERMITTED STRUCTURE BUILT PRIOR TO 2018 AND CONVERT TO ACCESSORY DWELLING UNIT WITH ATTACHED STORAGE PER LAMC 12.22 A.33(c) and (d) AND Government Code Section 65852.23. WORK PER ENGINEERING.
Permit Issued
Issued on 2/26/2024
Issuing Office
Current Status
Issued on 2/26/2024
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 12/4/2023 APPLICANT
Assigned to Plan Check Engineer 12/7/2023 OMAR GARNICA
Corrections Issued 12/8/2023 OMAR GARNICA
Plan Check Approved 2/21/2024 OMAR GARNICA
Issued 2/26/2024 APPLICANT

Permit Application Clearance Information

Miscellaneous Cleared 1/9/2024 ALEX VELA
Miscellaneous Cleared 1/9/2024 ALEX VELA
Address approval Cleared 1/11/2024 AMBER CAMPBELL
Roof/Waste drainage to street Cleared 1/11/2024 AMBER CAMPBELL
Eng Process Fee Ord 176,300 Cleared 1/18/2024 AMBER CAMPBELL
Sewer availability Cleared 1/18/2024 AMBER CAMPBELL
HPOZ Cleared 2/14/2024 DEBORAH MCGILL
Historic monument Cleared 2/14/2024 DEBORAH MCGILL

Contact Information

Architect Bernstein,, Alan Michael; Lic. No.: NA11415       ,
Contractor Addition Building & Design Inc; Lic. No.: 925471-B       ,
Engineer Mourad,, Daniel; Lic. No.: C83387 542 N FULLER AVE      LOS ANGELES, CA 90036

Inspector Information

RONNIE MINDANAO, (213) 202-3252 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 3/22/2024 Approved RONNIE MINDANAO
METHANE-Barrier 3/22/2024 Approved RONNIE MINDANAO
METHANE-Subgrade 3/22/2024 Approved RONNIE MINDANAO
PLUMBING-Rough 3/26/2024 Partial Approval RONNIE MINDANAO
Floor/Roof Diaphrgm/Shear Wall 5/2/2024 Partial Approval RONNIE MINDANAO
BUILDING-Rough-Frame 5/9/2024 Not Ready for Inspection RONNIE MINDANAO
ELECTRICAL-Rough 5/9/2024 Corrections Issued RONNIE MINDANAO
Green Building Rough 5/9/2024 Not Ready for Inspection RONNIE MINDANAO
METHANE-Rough 5/9/2024 Approved RONNIE MINDANAO
PLUMBING-Rough 5/9/2024 Corrections Issued RONNIE MINDANAO
ELECTRICAL-Rough 5/13/2024 Approved RONNIE MINDANAO
HVAC-Rough 5/13/2024 Approved RONNIE MINDANAO
BUILDING-Rough-Frame 5/14/2024 Corrections Issued RONNIE MINDANAO
Green Building Rough 5/14/2024 Not Ready for Inspection RONNIE MINDANAO
BUILDING-Rough-Frame 5/23/2024 Conditional Approval RONNIE MINDANAO
Green Building Rough 5/23/2024 Not Ready for Inspection RONNIE MINDANAO
Insulation 5/23/2024 Approved RONNIE MINDANAO
Interior/Exterior Lathing 5/23/2024 Conditional Approval RONNIE MINDANAO
Shower Pan 5/28/2024 Approved AMIR NAZARIAN
Drywall Nailing 6/3/2024 Conditional Approval RONNIE MINDANAO
Interior/Exterior Lathing 6/3/2024 Approved RONNIE MINDANAO
Underground Mechanical 6/17/2024 Approved AMIR NAZARIAN
BUILDING-Rough-Frame 8/5/2024 Not Ready for Inspection RONNIE MINDANAO
Final 8/5/2024 Corrections Issued RONNIE MINDANAO
Green Building Final 8/5/2024 Not Ready for Inspection RONNIE MINDANAO
Green Building Rough 8/5/2024 Not Ready for Inspection RONNIE MINDANAO
SGSOV-Seismic Gas S/O Valve 8/5/2024 SGSOV Not Ready RONNIE MINDANAO
Smoke Detectors 8/5/2024 Not Ready for Inspection RONNIE MINDANAO
BUILDING-Rough-Frame 8/12/2024 Approved RONNIE MINDANAO
Final 8/12/2024 Corrections Issued RONNIE MINDANAO
Green Building Final 8/12/2024 Approved RONNIE MINDANAO
Green Building Rough 8/12/2024 Approved RONNIE MINDANAO
SGSOV-Seismic Gas S/O Valve 8/12/2024 SGSOV Approved RONNIE MINDANAO
Smoke Detectors 8/12/2024 Approved RONNIE MINDANAO
Final 8/14/2024 Not Ready for Inspection RONNIE MINDANAO
Final 8/16/2024 Corrections Issued RONNIE MINDANAO
PLUMBING-Final 8/20/2024 Corrections Issued RONNIE MINDANAO
PLUMBING-Final 8/22/2024 Partial Approval RONNIE MINDANAO