4004 S 2ND AVE 90008

Certificate Information: 4004 S 2ND AVE 90008

Application / Permit
23014-10000-04476
Plan Check / Job No.
B23LA20629
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PROPOSED ADDITION TO SINGLE FAMILY DWELLING
Permit Issued
Issued on 12/28/2023
Issuing Office
Current Status
CofO Issued on 7/24/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/31/2023 APPLICANT
Assigned to Plan Check Engineer 11/2/2023 SINA KHOSRAVI
Corrections Issued 11/7/2023 SINA KHOSRAVI
Quality Review Completed 11/8/2023 KEN GILL
Building Plans Picked Up 11/9/2023 APPLICANT
Applicant returned to address corrections 12/21/2023 SINA KHOSRAVI
Plan Check Approved 12/28/2023 SINA KHOSRAVI
Issued 12/28/2023 APPLICANT
CofO in Progress 7/17/2024 CRAIG DAVIS
Permit Finaled 7/24/2024 DEROLD HAUFF
CofO Issued 7/24/2024 DEROLD HAUFF
Permit Finaled 7/24/2024 DEROLD HAUFF

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 11/13/2023 TREVOR QUAN
Sewer availability Cleared 11/13/2023 TREVOR QUAN
Eng Process Fee Ord 176,300 Cleared 11/14/2023 TREVOR QUAN

Contact Information

Contractor Owner-Builder       ,
Engineer Standley,, Craig Erick; Lic. No.: C87675 60 VIA CARATAMA      SAN CLEMENTE, CA 92673

Inspector Information

LUIS CASTRO, (213) 202-3436 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 1/18/2024 Corrections Issued ANTHONY EGSON
Excavation/Setback/Form/Re-Bar 1/24/2024 Approved ANTHONY EGSON
Footing/Foundation/Slab 1/24/2024 Approved ANTHONY EGSON
Floor/Roof Diaphrgm/Shear Wall 2/13/2024 Partial Approval BRENDAN MORELLI
ELECTRICAL-Rough 3/19/2024 Corrections Issued ANTHONY EGSON
Gas Test 3/19/2024 Corrections Issued ANTHONY EGSON
Interior/Exterior Lathing 3/19/2024 Corrections Issued ANTHONY EGSON
PLUMBING-Rough 3/19/2024 Corrections Issued ANTHONY EGSON
ELECTRICAL-Rough 3/29/2024 Approved ANTHONY EGSON
Interior/Exterior Lathing 3/29/2024 Not Ready for Inspection ANTHONY EGSON
BUILDING-Rough-Frame 4/2/2024 Not Ready for Inspection ANTHONY EGSON
Green Building Rough 4/2/2024 Not Ready for Inspection ANTHONY EGSON
Interior/Exterior Lathing 4/19/2024 Approved ANTHONY EGSON
Wood Frame 4/19/2024 Approved ANTHONY EGSON
Insulation 5/3/2024 Approved JOSH MEISTER
Drywall Nailing 5/9/2024 Approved ANTHONY EGSON
ELECTRICAL-Final 7/11/2024 Approved ANTHONY EGSON
Final 7/11/2024 Corrections Issued ANTHONY EGSON
Green Building Final 7/11/2024 Not Ready for Inspection ANTHONY EGSON
Green Building Rough 7/11/2024 Approved ANTHONY EGSON
SGSOV-Seismic Gas S/O Valve 7/11/2024 SGSOV Approved ANTHONY EGSON
Smoke Detectors 7/11/2024 No Access for Inspection ANTHONY EGSON
BUILDING-Rough-Frame 7/16/2024 Approved CRAIG DAVIS
ELECTRICAL-Final 7/16/2024 Approved CRAIG DAVIS
Final 7/16/2024 OK to Issue CofO CRAIG DAVIS
Green Building Final 7/16/2024 Approved CRAIG DAVIS
HVAC-Final 7/16/2024 Approved CRAIG DAVIS
Smoke Detectors 7/16/2024 Approved CRAIG DAVIS