5775-5775 1/2 W 74TH ST 90045
Certificate Information: 5775-5775 1/2 W 74TH ST 90045
- Application / Permit
- 23014-10000-03646
- Plan Check / Job No.
- B23LA16874
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- EPLAN: 15' x 33'-10" addition to existing one-story single-family dwelling with an attached ADU. All work done per engineering.
- Permit Issued
- Issued on 11/2/2023
- Issuing Office
- Current Status
- CofO Issued on 11/14/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/11/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 9/14/2023 | DANIEL SMILEY |
| Corrections Issued | 9/14/2023 | DANIEL SMILEY |
| Applicant returned to address corrections | 10/4/2023 | AUNG SOE |
| Plan Check Approved | 11/1/2023 | DANIEL SMILEY |
| Issued | 11/2/2023 | APPLICANT |
| CofO in Progress | 11/8/2024 | JESUS PINEDA |
| Permit Finaled | 11/14/2024 | RICHARD STEINBACH |
| CofO Issued | 11/14/2024 | RICHARD STEINBACH |
| Permit Finaled | 11/14/2024 | RICHARD STEINBACH |
Permit Application Clearance Information
| ZA Case | Cleared | 9/25/2023 | RUBEN VASQUEZ |
| Grading Pre-Inspection | Cleared | 10/12/2023 | ROBERT HUGHES |
| Low Impact Development (LID) | Cleared | 10/24/2023 | TOMMY YIN |
| Eng Process Fee Ord 176,300 | Cleared | 10/26/2023 | DARIN LAM |
| Roof/Waste drainage to street | Cleared | 10/26/2023 | DARIN LAM |
| Sewer availability | Cleared | 10/26/2023 | DARIN LAM |
Contact Information
| Contractor | Top Leader Construction Inc; Lic. No.: 1044906-B | , |
| Engineer | Ramirez, Cid, Jose Carlos; Lic. No.: C91046 | 5164 N RATON CIR LONG BEACH, CA 90807 |
| Engineer | Ramirez, Cid, Jose Carlos; Lic. No.: NA91046 | , |
Inspector Information
| MICHAEL LEWIS, (310) 914-3979 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 12/4/2023 | Approved | TEMISTOCLES CAAL |
| Footing/Foundation/Slab | 12/11/2023 | Corrections Issued | BOBBY KEY |
| Deputy Drilled-In Anchors | 12/12/2023 | Conditional Approval | BOBBY KEY |
| Footing/Foundation/Slab | 12/14/2023 | Approved | BOBBY KEY |
| ELECTRICAL-Rough | 1/22/2024 | Approved | JESUS RODRIGUEZ |
| PLUMBING-Rough | 1/22/2024 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 2/13/2024 | Corrections Issued | BOBBY KEY |
| Floor/Roof Diaphrgm/Shear Wall | 2/13/2024 | Approved | BOBBY KEY |
| Green Building Rough | 2/13/2024 | Not Ready for Inspection | BOBBY KEY |
| HVAC-Rough | 2/13/2024 | Corrections Issued | BOBBY KEY |
| BUILDING-Rough-Frame | 3/4/2024 | Conditional Approval | BOBBY KEY |
| Green Building Rough | 3/4/2024 | Not Ready for Inspection | BOBBY KEY |
| HVAC-Rough | 3/4/2024 | Approved | BOBBY KEY |
| Insulation | 3/4/2024 | Conditional Approval | BOBBY KEY |
| MERV13>=Rough | 3/4/2024 | Approved | BOBBY KEY |
| BUILDING-Rough-Frame | 3/26/2024 | Approved | BOBBY KEY |
| Drywall Nailing | 3/26/2024 | Approved | BOBBY KEY |
| Green Building Rough | 3/26/2024 | Approved | BOBBY KEY |
| Insulation | 3/26/2024 | Approved | BOBBY KEY |
| Interior/Exterior Lathing | 3/26/2024 | Partial Approval | BOBBY KEY |
| ELECTRICAL-Final | 5/14/2024 | Corrections Issued | BOBBY KEY |
| Final | 5/14/2024 | Corrections Issued | BOBBY KEY |
| Green Building Final | 5/14/2024 | Approved | BOBBY KEY |
| HVAC-Final | 5/14/2024 | Corrections Issued | BOBBY KEY |
| MERV13>=Final | 5/14/2024 | Approved | BOBBY KEY |
| PLUMBING-Final | 5/14/2024 | Approved | BOBBY KEY |
| SGSOV-Seismic Gas S/O Valve | 5/14/2024 | SGSOV Approved | BOBBY KEY |
| Smoke Detectors | 5/14/2024 | Corrections Issued | BOBBY KEY |
| ELECTRICAL-Final | 10/29/2024 | Approved | BOBBY KEY |
| Final | 10/29/2024 | Not Ready for Inspection | BOBBY KEY |
| HVAC-Final | 10/29/2024 | Not Ready for Inspection | BOBBY KEY |
| Smoke Detectors | 10/29/2024 | Corrections Issued | BOBBY KEY |
| HVAC-Final | 11/4/2024 | Approved | BOBBY KEY |
| Final | 11/8/2024 | OK to Issue CofO | JESUS PINEDA |
| Smoke Detectors | 11/8/2024 | Approved | JESUS PINEDA |