11420 W MISSISSIPPI AVE 90025

Certificate Information: 11420 W MISSISSIPPI AVE 90025

Application / Permit
23014-10000-03638
Plan Check / Job No.
B23LA16856
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
EPLAN PROPOSED ADDITIONTO EXISTING SINGLE FAMILY DWELLING.
Permit Issued
Issued on 7/10/2024
Issuing Office
Current Status
CofO in Progress on 7/24/2026
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/10/2023 APPLICANT
Assigned to Plan Check Engineer 9/14/2023 ARSALAN SHABESTARI
Corrections Issued 9/14/2023 ARSALAN SHABESTARI
Applicant returned to address corrections 3/6/2024 MICHAEL LOPEZ
Plan Check Approved 3/12/2024 PINANK PATEL
Issued 7/10/2024 APPLICANT
CofO in Progress 7/24/2026 HERBERT GIRON

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 10/2/2023 DARIN LAM
Sewer availability Cleared 10/2/2023 DARIN LAM
Specific Plan Cleared 10/19/2023 JULISSA LOPEZ-HODOYAN
Specific Plan Cleared 11/1/2023 PEDRO AYALA
Roof/Waste drainage to street Cleared 3/6/2024 DARIN LAM

Contact Information

Contractor Owner-Builder       ,
Engineer Xi,, Wang; Lic. No.: NA85148       ,

Inspector Information

ANTHONY EGSON, (310) 914-3893 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 9/10/2024 Conditional Approval MICHAEL PELHAM
Excavation/Setback/Form/Re-Bar 9/18/2024 Approved KIRK SANDERS
Footing/Foundation/Slab 9/18/2024 Approved KIRK SANDERS
Deputy Drilled-In Anchors 9/25/2024 Conditional Approval KIRK SANDERS
Insulation 9/26/2024 Corrections Issued KIRK SANDERS
Special/Order Compliance 9/26/2024 Corrections Issued KIRK SANDERS
Wood Frame 9/26/2024 Conditional Approval KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 9/27/2024 Partial Approval KIRK SANDERS
BUILDING-Rough-Frame 10/9/2024 Corrections Issued KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 10/9/2024 Partial Approval KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 11/5/2024 Partial Approval KIRK SANDERS
ELECTRICAL-Rough 12/16/2024 Corrections Issued STEPHANIE SWANSON
HVAC-Rough 12/16/2024 Corrections Issued STEPHANIE SWANSON
PLUMBING-Rough 12/16/2024 Not Ready for Inspection STEPHANIE SWANSON
BUILDING-Rough-Frame 12/20/2024 Corrections Issued KIRK SANDERS
Deputy Wood Construction 12/20/2024 Approved KIRK SANDERS
ELECTRICAL-Rough 12/20/2024 Not Ready for Inspection KIRK SANDERS
HVAC-Rough 12/20/2024 Conditional Approval KIRK SANDERS
PLUMBING-Rough 12/20/2024 Approved KIRK SANDERS
Underground Mechanical 12/20/2024 Partial Approval KIRK SANDERS
ELECTRICAL-Rough 3/19/2025 Approved BOBBY KEY
Floor/Roof Diaphrgm/Shear Wall 3/19/2025 Approved BOBBY KEY
Sewer 3/19/2025 Approved BOBBY KEY
BUILDING-Rough-Frame 3/24/2025 Partial Approval KIRK SANDERS
HVAC-Rough 3/24/2025 Approved KIRK SANDERS
Interior/Exterior Lathing 3/24/2025 Partial Approval KIRK SANDERS
Insulation 3/27/2025 Partial Approval KIRK SANDERS
Drywall Nailing 4/3/2025 Approved JAYLIN GRAVITTE
Insulation 4/3/2025 Approved JAYLIN GRAVITTE
Interior/Exterior Lathing 4/3/2025 Approved JAYLIN GRAVITTE
Shower Pan 4/3/2025 Approved JAYLIN GRAVITTE
BUILDING-Rough-Frame 5/13/2025 Approved KIRK SANDERS
Interior/Exterior Lathing 5/13/2025 Approved KIRK SANDERS
Deputy Drilled-In Anchors 8/8/2025 Conditional Approval ARAM AVEDISIAN
Final 9/10/2025 Corrections Issued ARAM AVEDISIAN
SGSOV-Seismic Gas S/O Valve 9/10/2025 SGSOV Approved ARAM AVEDISIAN
Smoke Detectors 9/10/2025 Approved ARAM AVEDISIAN
Final 6/1/2026 Corrections Issued ANTHONY EGSON
Final 7/10/2026 Not Ready for Inspection ANTHONY EGSON
Final 7/24/2026 OK to Issue CofO HERBERT GIRON
Service/Power Release 7/24/2026 Approved HERBERT GIRON