22700 W CALVERT ST 91367
Certificate Information: 22700 W CALVERT ST 91367
- Application / Permit
- 23014-10000-00132
- Plan Check / Job No.
- B22VN17849
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- eplan 1/2 ADDITION TO EXISTISTING SFD. ADDITION AT FRONT OF HOUSE AND ADDITION OF RECREATION ROOM TO ATTACHED GARGAE SEE COMMENTS FOR (E) BREEZEWAY NOTE.
- Permit Issued
- Issued on 8/30/2023
- Issuing Office
- Current Status
- CofO Issued on 9/26/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/6/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/5/2023 | MARCELA FRANQUEZ |
| Corrections Issued | 1/10/2023 | MARCELA FRANQUEZ |
| Quality Review Completed | 1/19/2023 | TEODORO DIAZ RODRIGUEZ |
| Applicant returned to address corrections | 5/9/2023 | MARCELA FRANQUEZ |
| Applicant returned to address corrections | 7/12/2023 | MARCELA FRANQUEZ |
| Plan Check Approved | 8/4/2023 | MARCELA FRANQUEZ |
| Plan Check Approved | 8/4/2023 | MARCELA FRANQUEZ |
| No Progress | 8/8/2023 | MARCELA FRANQUEZ |
| Plan Check Approved | 8/8/2023 | MARCELA FRANQUEZ |
| Issued | 8/30/2023 | APPLICANT |
| CofO in Progress | 9/13/2024 | TROY SANDERS |
| Permit Finaled | 9/26/2024 | JOHN JANSON |
| CofO Issued | 9/26/2024 | JOHN JANSON |
| Permit Finaled | 9/26/2024 | JOHN JANSON |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 6/20/2023 | COLIN LOREDO |
| Sewer availability | Cleared | 6/20/2023 | COLIN LOREDO |
| Low Impact Development | Cleared | 6/30/2023 | ERNEST TSE |
| GPI Written Notices | Cleared | 7/12/2023 | MARCELA FRANQUEZ |
| Grading Pre-Inspection | Cleared | 7/12/2023 | MARCELA FRANQUEZ |
| Roof/Waste drainage to street | Cleared | 7/26/2023 | ROMAN GUTIERREZ |
Contact Information
| Contractor | Build 4 You Inc; Lic. No.: 914440-B | , |
| Engineer | Melchor,, Oscar Elias; Lic. No.: C76828 | 21243 VENTURA BLVD SUITE 119 WOODLAND HILLS, CA 91364 |
Inspector Information
| GEVORK IPCHYAN, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
| TROY SANDERS, (818) 774-4308 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 9/5/2023 | Partial Approval | TROY SANDERS |
| Deputy Drilled-In Anchors | 9/13/2023 | Conditional Approval | TROY SANDERS |
| Footing/Foundation/Slab | 9/18/2023 | Approved | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/10/2023 | Not Ready for Inspection | TROY SANDERS |
| Insulation | 10/10/2023 | Partial Approval | TROY SANDERS |
| PLUMBING-Rough | 10/10/2023 | Partial Approval | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 10/12/2023 | Partial Approval | TROY SANDERS |
| Sewer | 11/2/2023 | Approved | TROY SANDERS |
| Deputy Wood Construction | 11/13/2023 | Conditional Approval | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 11/13/2023 | Partial Approval | TROY SANDERS |
| ELECTRICAL-Rough | 12/22/2023 | Approved | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 12/22/2023 | Partial Approval | TROY SANDERS |
| HVAC-Rough | 12/22/2023 | Approved | TROY SANDERS |
| PLUMBING-Rough | 12/22/2023 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 1/8/2024 | Not Ready for Inspection | HENRY KIM |
| Shower Pan | 1/8/2024 | Approved | HENRY KIM |
| BUILDING-Rough-Frame | 1/10/2024 | Approved | TROY SANDERS |
| Green Building Rough | 1/10/2024 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 1/10/2024 | Partial Approval | TROY SANDERS |
| Rough-Elec/Plmb/HVAC | 1/10/2024 | Approved | TROY SANDERS |
| Shower Pan | 1/10/2024 | Approved | TROY SANDERS |
| Insulation | 1/12/2024 | Approved | TROY SANDERS |
| Drywall Nailing | 1/18/2024 | Approved | TROY SANDERS |
| Interior/Exterior Lathing | 1/18/2024 | Partial Approval | TROY SANDERS |
| Sewer | 4/8/2024 | Approved | TROY SANDERS |
| Sewer | 4/11/2024 | Approved | TROY SANDERS |
| Final | 6/12/2024 | Not Ready for Inspection | TROY SANDERS |
| Green Building Final | 6/12/2024 | Not Ready for Inspection | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 6/12/2024 | SGSOV Approved | TROY SANDERS |
| Smoke Detectors | 6/12/2024 | Approved | TROY SANDERS |
| Final | 6/28/2024 | Not Ready for Inspection | GEVORK IPCHYAN |
| Green Building Final | 6/28/2024 | Not Ready for Inspection | GEVORK IPCHYAN |
| Final | 7/8/2024 | Not Ready for Inspection | TROY SANDERS |
| Green Building Final | 7/8/2024 | Approved | TROY SANDERS |
| Final | 9/13/2024 | OK to Issue CofO | TROY SANDERS |