5628 N KATHERINE AVE 91401
Certificate Information: 5628 N KATHERINE AVE 91401
- Application / Permit
- 23010-20000-05116
- Plan Check / Job No.
- B23VN17439
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- New irregular shaped two story 68' 3" x 53' Single family dwelling wtith attached garage and attached trellis in the back, NFPA 13D sprinkler required. All work done per engineer.
- Permit Issued
- Issued on 3/27/2024
- Issuing Office
- Current Status
- Issued on 3/27/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/20/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 1/11/2024 | NAREG ATARIAN |
| Corrections Issued | 1/17/2024 | NAREG ATARIAN |
| Quality Review Completed | 1/24/2024 | OMID HEDAYAT |
| Building Plans Picked Up | 1/25/2024 | APPLICANT |
| Plan Check Approved | 3/27/2024 | NAREG ATARIAN |
| Issued | 3/27/2024 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 1/22/2024 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 2/8/2024 | CARLOS AGUILERA |
| Sewer availability | Cleared | 2/8/2024 | CARLOS AGUILERA |
| Hydrant and Access approval | Cleared | 3/23/2024 | GILBERT URREA |
| Low Impact Development (LID) | Cleared | 3/26/2024 | TOMMY YIN |
| Roof/Waste drainage to street | Cleared | 3/26/2024 | CARLOS RAMIREZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 3625 BEVERLY RIDGE DRIVE SHERMAN OAKS, CA 91423 |
Inspector Information
| JOSE AVILA, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
| VINCENT HANLEY, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 6/14/2024 | Partial Approval | RYAN SALAZAR |
| PLUMBING-Rough | 7/23/2025 | Partial Approval | GAREN HAYRAPETYAN |
| Footing/Foundation/Slab | 11/4/2025 | Approved | RYAN SALAZAR |
| Floor/Roof Diaphrgm/Shear Wall | 12/15/2025 | Not Ready for Inspection | RYAN SALAZAR |
| Floor/Roof Diaphrgm/Shear Wall | 1/28/2026 | Partial Approval | JACK KARGODORIAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/4/2026 | Partial Approval | VINCENT HANLEY |
| Underground Mechanical | 4/7/2026 | Approved | VINCENT HANLEY |
| BUILDING-Rough-Frame | 4/10/2026 | Partial Approval | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 4/10/2026 | Approved | VINCENT HANLEY |
| Green Building Rough | 4/10/2026 | Not Ready for Inspection | VINCENT HANLEY |
| Verify Sprinkler Sign Off | 4/10/2026 | Not Ready for Inspection | VINCENT HANLEY |
| BUILDING-Rough-Frame | 4/30/2026 | Approved | VINCENT HANLEY |
| Green Building Rough | 4/30/2026 | Approved | VINCENT HANLEY |
| Rough-Elec/Plmb/HVAC | 4/30/2026 | Approved | VINCENT HANLEY |
| Verify Sprinkler Sign Off | 4/30/2026 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 5/21/2026 | Partial Approval | VINCENT HANLEY |
| Insulation | 5/26/2026 | Approved | VINCENT HANLEY |
| Drywall Nailing | 6/9/2026 | Approved | VINCENT HANLEY |