8351 N COLBATH AVE 91402
Certificate Information: 8351 N COLBATH AVE 91402
- Application / Permit
- 23010-20000-05075
- Plan Check / Job No.
- B23VN17314
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 31'-0" X 27'-6" IRREGULAR SHAPED ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d). ALL WORK DONE PER WFPP.
- Permit Issued
- Issued on 6/3/2024
- Issuing Office
- Valley
- Current Status
- CofO Issued on 12/19/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/18/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 12/20/2023 | ARTIN ZARUKIAN |
| Corrections Issued | 12/26/2023 | ARTIN ZARUKIAN |
| Building Plans Picked Up | 1/17/2024 | APPLICANT |
| Applicant returned to address corrections | 1/25/2024 | LUISANGEL VALENZUELA |
| Applicant returned to address corrections | 5/21/2024 | ANGELICA DAVE |
| Plan Check Approved | 5/29/2024 | DANIEL ABRAMYAN |
| Issued | 6/3/2024 | APPLICANT |
| CofO in Progress | 11/30/2024 | GREGG CUMMINGS |
| Permit Finaled | 12/19/2024 | RUBEN SALAS |
| CofO Issued | 12/19/2024 | RUBEN SALAS |
| Permit Finaled | 12/19/2024 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 1/19/2024 | RYAN KIM |
| Eng Process Fee Ord 176,300 | Cleared | 1/22/2024 | RYAN KIM |
| Sewer availability | Cleared | 1/22/2024 | RYAN KIM |
| Low Impact Development (LID) | Cleared | 4/4/2024 | ROGELIO CORTES |
| Roof/Waste drainage to street | Cleared | 4/8/2024 | CARLOS AGUILERA |
| Construction near power lines | Cleared | 5/16/2024 | RIDWAN HARDY |
Contact Information
| Contractor | South Land Remodeling Inc; Lic. No.: 901842-B | 15021 VENTURA BLVD #488 SHERMAN OAKS, CA 91403 |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 6/26/2024 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 7/2/2024 | Partial Approval | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 7/5/2024 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 7/5/2024 | Approved | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 8/9/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Rough | 8/9/2024 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 8/9/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Green Building Rough | 8/9/2024 | Corrections Issued | GREGG CUMMINGS |
| HVAC-Rough | 8/9/2024 | Corrections Issued | GREGG CUMMINGS |
| PLUMBING-Rough | 8/9/2024 | Approved | GREGG CUMMINGS |
| Sewer | 8/9/2024 | Approved | GREGG CUMMINGS |
| Underground Mechanical | 8/9/2024 | Partial Approval | GREGG CUMMINGS |
| Verify Sprinkler Sign Off | 8/9/2024 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 8/13/2024 | Partial Approval | GREGG CUMMINGS |
| HVAC-Rough | 8/13/2024 | Approved | GREGG CUMMINGS |
| Underground Mechanical | 8/13/2024 | Partial Approval | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 8/22/2024 | Corrections Issued | GREGG CUMMINGS |
| Insulation | 8/27/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Interior/Exterior Lathing | 8/27/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 8/30/2024 | Partial Approval | VINCENT HANLEY |
| Green Building Rough | 8/30/2024 | Approved | VINCENT HANLEY |
| Insulation | 8/30/2024 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 8/30/2024 | Partial Approval | VINCENT HANLEY |
| Drywall Nailing | 9/4/2024 | Approved | GAREN HAYRAPETYAN |
| Interior/Exterior Lathing | 9/12/2024 | Approved | GAREN HAYRAPETYAN |
| Shower Pan | 9/12/2024 | Approved | GAREN HAYRAPETYAN |
| BUILDING-Rough-Frame | 10/25/2024 | Approved | GREGG CUMMINGS |
| Final | 10/25/2024 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 10/25/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 10/25/2024 | SGSOV Not Ready | GREGG CUMMINGS |
| Service/Power Release | 10/25/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Smoke Detectors | 10/25/2024 | Approved | GREGG CUMMINGS |
| Final | 11/22/2024 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 11/22/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 11/22/2024 | SGSOV Approved | GREGG CUMMINGS |
| Service/Power Release | 11/22/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Final | 11/27/2024 | Approved | GREGG CUMMINGS |
| Final | 11/27/2024 | OK to Issue CofO | GREGG CUMMINGS |
| Green Building Final | 11/27/2024 | Approved | GREGG CUMMINGS |
| HVAC-Final | 11/27/2024 | Approved | GREGG CUMMINGS |
| PLUMBING-Final | 11/27/2024 | Approved | GREGG CUMMINGS |
| Service/Power Release | 11/27/2024 | Approved | GREGG CUMMINGS |