8751 N GOTHIC AVE 91343

Certificate Information: 8751 N GOTHIC AVE 91343

Application / Permit
23010-20000-03966
Plan Check / Job No.
B23VN13475
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 22'-0" X 30'-2" IRREGULAR SHAPED DETACHED ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d) WITH 5' X 9'5" ATTACHED PATIO COVER. WORK PER ENGINEERED DESIGN.
Permit Issued
Issued on 4/8/2024
Issuing Office
Valley
Current Status
CofO Issued on 2/18/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/3/2023 APPLICANT
Assigned to Plan Check Engineer 10/6/2023 ARTIN ZARUKIAN
Corrections Issued 10/7/2023 ARTIN ZARUKIAN
Building Plans Picked Up 10/12/2023 APPLICANT
Applicant returned to address corrections 2/28/2024 LUISANGEL VALENZUELA
Applicant returned to address corrections 4/4/2024 DANIEL ABRAMYAN
Plan Check Approved 4/8/2024 OMAR GARNICA
Issued 4/8/2024 APPLICANT
CofO in Progress 1/22/2025 SALVADOR MARTINEZ
Permit Finaled 2/18/2025 RUBEN SALAS
CofO Issued 2/18/2025 RUBEN SALAS
Permit Finaled 2/18/2025 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 11/6/2023 CARLOS AGUILERA
Sewer availability Cleared 11/6/2023 CARLOS AGUILERA
Low Impact Development (LID) Cleared 2/2/2024 MITESH PATEL
Eng Process Fee Ord 176,300 Cleared 2/13/2024 CARLOS AGUILERA
Roof/Waste drainage to street Cleared 2/13/2024 CARLOS RAMIREZ
Construction near power lines Cleared 3/26/2024 RIDWAN HARDY

Contact Information

Contractor E M M C Design & Construction; Lic. No.: 1016221-B 427 N KINGSLEY DR #5      LOS ANGELES, CA 90004
Engineer Mah,, Edwin Poy-Dor; Lic. No.: C27141 1740 APPIAN WAY      MONTEBELLO, CA 90640

Inspector Information

MICHAEL CORTEZ, (818) 374-1176 Office Hours: 7:00-8:00 AM MON-FRI
WILLIAM WREN, (818) 374-1176 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 5/6/2024 Corrections Issued RAUL OLAGI
PLUMBING-Rough 5/8/2024 Conditional Approval RAUL OLAGI
Excavation/Setback/Form/Re-Bar 5/15/2024 Approved RAUL OLAGI
Footing/Foundation/Slab 5/15/2024 Approved RAUL OLAGI
Sewer 5/21/2024 Approved MICHEL ABAJAN
Floor/Roof Diaphrgm/Shear Wall 6/27/2024 Approved RAUL OLAGI
ELECTRICAL-Rough 8/1/2024 Corrections Issued SALVADOR MARTINEZ
Interior/Exterior Lathing 8/1/2024 Corrections Issued SALVADOR MARTINEZ
PLUMBING-Rough 8/1/2024 Corrections Issued SALVADOR MARTINEZ
Shower Pan 8/1/2024 Approved SALVADOR MARTINEZ
BUILDING-Rough-Frame 8/5/2024 Not Ready for Inspection SALVADOR MARTINEZ
ELECTRICAL-Rough 8/5/2024 Corrections Issued SALVADOR MARTINEZ
HVAC-Rough 8/5/2024 Corrections Issued SALVADOR MARTINEZ
Interior/Exterior Lathing 8/5/2024 Partial Approval SALVADOR MARTINEZ
PLUMBING-Rough 8/5/2024 Approved SALVADOR MARTINEZ
Service/Power Release 8/5/2024 Not Ready for Inspection SALVADOR MARTINEZ
BUILDING-Rough-Frame 8/8/2024 Approved SALVADOR MARTINEZ
ELECTRICAL-Rough 8/8/2024 Approved SALVADOR MARTINEZ
Green Building Rough 8/8/2024 Approved SALVADOR MARTINEZ
HVAC-Rough 8/8/2024 Approved SALVADOR MARTINEZ
Verify Sprinkler Sign Off 8/8/2024 Approved SALVADOR MARTINEZ
Insulation 8/14/2024 Approved LOUIS ESCOTO
Drywall Nailing 8/28/2024 Approved MICHAEL CORTEZ
Final 12/6/2024 Corrections Issued SALVADOR MARTINEZ
Green Building Final 12/6/2024 Not Ready for Inspection SALVADOR MARTINEZ
SGSOV-Seismic Gas S/O Valve 12/6/2024 SGSOV No Gas SALVADOR MARTINEZ
Service/Power Release 12/6/2024 Not Ready for Inspection SALVADOR MARTINEZ
Smoke Detectors 12/6/2024 Corrections Issued SALVADOR MARTINEZ
ELECTRICAL-Final 1/21/2025 Approved SALVADOR MARTINEZ
Final 1/21/2025 OK to Issue CofO SALVADOR MARTINEZ
Green Building Final 1/21/2025 Approved SALVADOR MARTINEZ
HVAC-Final 1/21/2025 Approved SALVADOR MARTINEZ
PLUMBING-Final 1/21/2025 Approved SALVADOR MARTINEZ
Service/Power Release 1/21/2025 Approved SALVADOR MARTINEZ
Smoke Detectors 1/21/2025 Approved SALVADOR MARTINEZ