20410-20412 W DEVONSHIRE ST 91311

Certificate Information: 20410-20412 W DEVONSHIRE ST 91311

Application / Permit
23010-20000-03657
Plan Check / Job No.
B23VN12348
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 41' X 21' DWELLING UNIT PER SB 9 ON FIRST FLOOR AND ACCESSORY DWELLING UNIT ON SECOND FLOOR; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT
Permit Issued
Issued on 1/30/2024
Issuing Office
Current Status
CofO Issued on 1/17/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/12/2023 APPLICANT
Assigned to Plan Check Engineer 9/14/2023 SELLA BENYAMIN
Corrections Issued 9/21/2023 SELLA BENYAMIN
Quality Review Completed 9/22/2023 STEVEN KIM
Applicant returned to address corrections 1/18/2024 SELLA BENYAMIN
Plan Check Approved 1/30/2024 SELLA BENYAMIN
Issued 1/30/2024 APPLICANT
CofO in Progress 1/14/2025 DAVID SCANTLIN
Permit Finaled 1/17/2025 JOHN JANSON
CofO Issued 1/17/2025 JOHN JANSON
Permit Finaled 1/17/2025 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 10/18/2023 EDGAR ALCARAZ
Eng Process Fee Ord 176,300 Cleared 10/18/2023 EDGAR ALCARAZ
Sewer availability Cleared 11/7/2023 BRYAN GODINEZ
Low Impact Development (LID) Cleared 11/15/2023 SAMUEL LINN
Roof/Waste drainage to street Cleared 11/15/2023 BRYAN GODINEZ
Senate Bill 9 Cleared 11/20/2023 SPENCER WEJROWSKI
Hydrant and Access approval Cleared 1/5/2024 GILBERT URREA

Contact Information

Contractor Owner-Builder       ,
Engineer Mroczka,, Peter J; Lic. No.: C42648 9301 DARBY AVE APT 1      NORTHRIDGE, CA 91325

Inspector Information

JACK KARGODORIAN, (818) 774-4319 Office Hours: 7:00-8:00 AM MON-FRI
KRISTEN CAUSEY, (818) 774-4319 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 2/20/2024 Not Ready for Inspection KRISTEN CAUSEY
PLUMBING-Rough 2/22/2024 Partial Approval DAVID SCANTLIN
Footing/Foundation/Slab 2/28/2024 Approved DAVID SCANTLIN
Floor/Roof Diaphrgm/Shear Wall 3/11/2024 Partial Approval DAVID SCANTLIN
Floor/Roof Diaphrgm/Shear Wall 3/22/2024 Approved DAVID SCANTLIN
Green Building Rough 3/22/2024 Not Ready for Inspection DAVID SCANTLIN
Interior/Exterior Lathing 3/22/2024 Not Ready for Inspection DAVID SCANTLIN
Verify Sprinkler Sign Off 3/22/2024 Not Ready for Inspection DAVID SCANTLIN
Interior/Exterior Lathing 4/11/2024 Partial Approval DAVID SCANTLIN
ELECTRICAL-Rough 4/23/2024 Approved DAVID SCANTLIN
HVAC-Rough 4/23/2024 Approved DAVID SCANTLIN
PLUMBING-Rough 4/23/2024 Approved DAVID SCANTLIN
BUILDING-Rough-Frame 5/17/2024 Approved DAVID SCANTLIN
Green Building Rough 5/17/2024 Approved DAVID SCANTLIN
Insulation 5/17/2024 Approved DAVID SCANTLIN
Verify Sprinkler Sign Off 5/17/2024 Approved DAVID SCANTLIN
Drywall Nailing 5/22/2024 Corrections Issued HENRY KIM
Drywall Nailing 5/28/2024 Approved DAVID SCANTLIN
Shower Pan 6/12/2024 Approved DAVID SCANTLIN
Interior/Exterior Lathing 7/5/2024 Approved JEFFREY PARD
Final 9/3/2024 Corrections Issued DAVID SCANTLIN
Green Building Final 9/3/2024 Not Ready for Inspection DAVID SCANTLIN
SGSOV-Seismic Gas S/O Valve 9/3/2024 SGSOV Approved DAVID SCANTLIN
Service/Power Release 9/3/2024 Not Ready for Inspection DAVID SCANTLIN
Smoke Detectors 9/3/2024 Approved DAVID SCANTLIN
Final 1/14/2025 OK to Issue CofO DAVID SCANTLIN
Green Building Final 1/14/2025 Approved DAVID SCANTLIN
Service/Power Release 1/14/2025 Approved DAVID SCANTLIN