4254 N BAKMAN AVE 91602
Certificate Information: 4254 N BAKMAN AVE 91602
- Application / Permit
- 23010-20000-03510
- Plan Check / Job No.
- B23VN11825
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- EPLAN: (N) 24'-8" X 37'-6" 1-STORY DETACHED ACCESORY DWELLING UNIT W/ COVERED PORCH PER CA Govt. Code 65852.2(e)(1)(B) and applicable part2 of LAMC 12.22 A.33 (c)-(d), (g). WORK PER ENGINEERING.
- Permit Issued
- Issued on 6/2/2024
- Issuing Office
- Current Status
- Issued on 6/2/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 8/31/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 9/8/2023 | ISIS ARGUETA |
| Corrections Issued | 9/11/2023 | ISIS ARGUETA |
| Applicant returned to address corrections | 12/25/2023 | ISIS ARGUETA |
| Applicant returned to address corrections | 1/5/2024 | ISIS ARGUETA |
| Applicant returned to address corrections | 2/6/2024 | LUISANGEL VALENZUELA |
| Plan Check Approved | 2/19/2024 | LUISANGEL VALENZUELA |
| Issued | 6/2/2024 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 9/20/2023 | DAGOVERTO GUERRERO |
| Eng Process Fee Ord 176,300 | Cleared | 9/21/2023 | DAGOVERTO GUERRERO |
| Sewer availability | Cleared | 9/21/2023 | DAGOVERTO GUERRERO |
| ZA Case | Cleared | 9/28/2023 | BRENNEN OBETO |
| Low Impact Development (LID) | Cleared | 12/14/2023 | TOMMY YIN |
| Roof/Waste drainage to street | Cleared | 12/18/2023 | BRYAN GODINEZ |
| Construction near power lines | Cleared | 2/1/2024 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Garcia,, Francisco Diaz; Lic. No.: C88029 | 19145 MALABAR ST SANTA CLARITA, CA 91351 |
Inspector Information
| JAVIER RAMOS JR, (818) 374-1163 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 8/7/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Underground Mechanical | 8/7/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Footing/Foundation/Slab | 8/12/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Underground Mechanical | 8/12/2024 | Approved | CHRISTOPHER ROJAS |
| Floor/Roof Diaphrgm/Shear Wall | 10/3/2024 | Approved | CHRISTOPHER ROJAS |
| Verify Sprinkler Sign Off | 10/3/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Interior/Exterior Lathing | 10/28/2024 | Partial Approval | JACK KARGODORIAN |
| BUILDING-Rough-Frame | 10/30/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| ELECTRICAL-Rough | 10/30/2024 | Partial Inspection | CHRISTOPHER ROJAS |
| HVAC-Rough | 10/30/2024 | Partial Inspection | CHRISTOPHER ROJAS |
| PLUMBING-Rough | 10/30/2024 | Partial Inspection | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 11/12/2024 | Partial Approval | CHRISTOPHER ROJAS |
| Interior/Exterior Lathing | 11/12/2024 | Approved | CHRISTOPHER ROJAS |
| Rough-Elec/Plmb/HVAC | 11/12/2024 | Approved | CHRISTOPHER ROJAS |
| Shower Pan | 11/12/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Verify Sprinkler Sign Off | 11/12/2024 | Approved | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 11/22/2024 | Approved | CHRISTOPHER ROJAS |
| Insulation | 11/22/2024 | Approved | CHRISTOPHER ROJAS |
| Shower Pan | 11/22/2024 | Approved | CHRISTOPHER ROJAS |
| Drywall Nailing | 12/12/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Drywall Nailing | 12/17/2024 | Approved | MICHAEL CORTEZ |
| Final | 2/11/2025 | Corrections Issued | CHRISTOPHER ROJAS |
| Underground Mechanical | 2/11/2025 | Partial Approval | CHRISTOPHER ROJAS |
| ELECTRICAL-Final | 4/9/2025 | Partial Inspection | JAVIER RAMOS JR |
| Final | 4/9/2025 | Corrections Issued | JAVIER RAMOS JR |
| Footing/Foundation/Slab | 4/9/2025 | Approved | JAVIER RAMOS JR |
| HVAC-Final | 4/9/2025 | Approved | JAVIER RAMOS JR |
| PLUMBING-Final | 4/9/2025 | Approved | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 4/9/2025 | SGSOV Not Required | JAVIER RAMOS JR |
| Service/Power Release | 4/9/2025 | Not Ready for Inspection | JAVIER RAMOS JR |
| Smoke Detectors | 4/9/2025 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Final | 5/8/2025 | Approved | JAVIER RAMOS JR |
| Final | 5/8/2025 | Partial Inspection | JAVIER RAMOS JR |
| Service/Power Release | 5/8/2025 | Not Ready for Inspection | JAVIER RAMOS JR |
| Service/Power Release | 7/14/2025 | Approved | JAVIER RAMOS JR |
| Pre-Inspection | 3/31/2026 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |