17646 W TRIBUNE ST 91344

Certificate Information: 17646 W TRIBUNE ST 91344

Application / Permit
23010-20000-03354
Plan Check / Job No.
B23VN11211
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 42' X 20' SINGLE FAMILY DWELLING PER SB9; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT
Permit Issued
Issued on 12/19/2023
Issuing Office
Current Status
CofO Issued on 4/2/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/21/2023 APPLICANT
Assigned to Plan Check Engineer 8/24/2023 SELLA BENYAMIN
Corrections Issued 8/29/2023 SELLA BENYAMIN
Quality Review Completed 8/29/2023 STEVEN KIM
Building Plans Picked Up 9/5/2023 APPLICANT
Plan Check Approved 11/16/2023 SELLA BENYAMIN
Issued 12/19/2023 APPLICANT
CofO in Progress 3/26/2025 STEVEN BACK
CofO Issued 4/2/2025 JOHN JANSON
Permit Finaled 4/2/2025 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 9/6/2023 TAL SHEMEN
Eng Process Fee Ord 176,300 Cleared 9/6/2023 TAL SHEMEN
Sewer availability Cleared 9/6/2023 TAL SHEMEN
Hydrant and Access approval Cleared 9/22/2023 GILBERT URREA
Low Impact Development (LID) Cleared 9/28/2023 SARAH YOUSSEF
Roof/Waste drainage to street Cleared 10/3/2023 TAL SHEMEN
Miscellaneous Cleared 11/13/2023 NELSON RODRIGUEZ
Senate Bill 9 Cleared 11/13/2023 NELSON RODRIGUEZ
Miscellaneous Cleared 12/18/2023 MAX LODER

Contact Information

Contractor Owner-Builder       ,

Inspector Information

JEFFREY PARD, (818) 774-4312 Office Hours: 7:00-8:00 AM MON-FRI
STEVEN BACK, (818) 774-4312 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 1/3/2024 Not Ready for Inspection STEVEN BACK
Excavation/Setback/Form/Re-Bar 1/5/2024 Not Ready for Inspection STEVEN BACK
PLUMBING-Rough 1/5/2024 Partial Approval STEVEN BACK
Excavation/Setback/Form/Re-Bar 1/9/2024 Approved KRISTEN CAUSEY
Floor/Roof Diaphrgm/Shear Wall 2/2/2024 Corrections Issued STEVEN BACK
ELECTRICAL-Rough 3/8/2024 Approved STEVEN BACK
Floor/Roof Diaphrgm/Shear Wall 3/8/2024 Approved STEVEN BACK
HVAC-Rough 3/8/2024 Corrections Issued STEVEN BACK
PLUMBING-Rough 3/8/2024 Approved STEVEN BACK
Special/Order Compliance 3/8/2024 Corrections Issued STEVEN BACK
BUILDING-Rough-Frame 4/11/2024 Not Ready for Inspection STEVEN BACK
Green Building Rough 4/11/2024 Not Ready for Inspection STEVEN BACK
HVAC-Rough 4/11/2024 Approved STEVEN BACK
Interior/Exterior Lathing 4/11/2024 Not Ready for Inspection STEVEN BACK
Verify Sprinkler Sign Off 4/11/2024 Approved STEVEN BACK
Shower Pan 4/18/2024 Approved STEVEN BACK
BUILDING-Rough-Frame 4/22/2024 Approved STEVEN BACK
Green Building Rough 4/22/2024 Approved STEVEN BACK
Interior/Exterior Lathing 4/22/2024 Partial Approval STEVEN BACK
Insulation 4/25/2024 Corrections Issued STEVEN BACK
Drywall Nailing 4/30/2024 Approved JEFFREY PARD
Insulation 4/30/2024 Approved JEFFREY PARD
Interior/Exterior Lathing 5/8/2024 Approved STEVEN BACK
Pre-Inspection 6/5/2024 Partial Inspection STEVEN BACK
Special/Order Compliance 10/8/2024 Corrections Issued STEVEN BACK
Final 2/6/2025 Corrections Issued STEVEN BACK
Footing/Foundation/Slab 2/6/2025 Approved STEVEN BACK
SGSOV-Seismic Gas S/O Valve 2/6/2025 SGSOV Not Required STEVEN BACK
Smoke Detectors 2/6/2025 Approved STEVEN BACK
Final 3/24/2025 No Access for Inspection STEVEN BACK
Green Building Final 3/24/2025 No Access for Inspection STEVEN BACK
Final 3/26/2025 OK to Issue CofO STEVEN BACK
Green Building Final 3/26/2025 Approved STEVEN BACK
Service/Power Release 3/26/2025 Approved STEVEN BACK